首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Retrospective assessment of a single fiducial marker tracking regimen with robotic stereotactic body radiation therapy for liver tumours
Institution:1. Division of Radiation Oncology, Kobe University Graduate School of Medicine, 7-5-2 Kusunokicho, Chuou-ku, Kobe City, Hyogo 650-0017, Japan;2. Discipline of Medical Radiations, School of Biomedical & Health Sciences, RMIT University, Bundoora Campus, Victoria 3083, Australia;3. Division of Radiation Oncology, Kobe Minimally Invasive Cancer Center, 8-5-1 Minatojima-nakamachi, Chuou-ku, Kobe City, Hyogo 650-0046, Japan;4. Department of Radiation Oncology, Hyogo Cancer Center, 13-70 Kitaojicho, Akashi City, Hyogo 637-8558, Japan
Abstract:AimTo investigate tumour motion tracking uncertainties in the CyberKnife Synchrony system with single fiducial marker in liver tumours.BackgroundIn the fiducial-based CyberKnife real-time tumour motion tracking system, multiple fiducial markers are generally used to enable translation and rotation corrections during tracking. However, sometimes a single fiducial marker is employed when rotation corrections are not estimated during treatment.Materials and methodsData were analysed for 32 patients with liver tumours where one fiducial marker was implanted. Four-dimensional computed tomography (CT) scans were performed to determine the internal target volume (ITV). Before the first treatment fraction, the CT scans were repeated and the marker migration was determined. Log files generated by the Synchrony system were obtained after each treatment and the correlation model errors were calculated. Intra-fractional spine rotations were examined on the spine alignment images before and after each treatment.ResultsThe mean (standard deviation) ITV margin was 4.1 (2.3) mm, which correlated weakly with the distance between the fiducial marker and the tumour. The mean migration distance of the marker was 1.5 (0.7) mm. The overall mean correlation model error was 1.03 (0.37) mm in the radial direction. The overall mean spine rotations were 0.27° (0.31), 0.25° (0.22), and 0.23° (0.26) for roll, pitch, and yaw, respectively. The treatment time was moderately associated with the correlation model errors and weakly related to spine rotation in the roll and yaw planes.ConclusionsMore caution and an additional safety margins are required when tracking a single fiducial marker.
Keywords:CyberKnife  Synchrony system  Fiducial marker tracking  Liver tumour  AP"}  {"#name":"keyword"  "$":{"id":"kw0030"}  "$$":[{"#name":"text"  "_":"anterior–posterior  CTV"}  {"#name":"keyword"  "$":{"id":"kw0040"}  "$$":[{"#name":"text"  "_":"clinical target volume  GTV"}  {"#name":"keyword"  "$":{"id":"kw0050"}  "$$":[{"#name":"text"  "_":"gross tumour volume  LED"}  {"#name":"keyword"  "$":{"id":"kw0060"}  "$$":[{"#name":"text"  "_":"light-emitting diode  ITV"}  {"#name":"keyword"  "$":{"id":"kw0070"}  "$$":[{"#name":"text"  "_":"internal target volume  LR"}  {"#name":"keyword"  "$":{"id":"kw0080"}  "$$":[{"#name":"text"  "_":"left–right  PTV"}  {"#name":"keyword"  "$":{"id":"kw0090"}  "$$":[{"#name":"text"  "_":"planning target volume  SBRT"}  {"#name":"keyword"  "$":{"id":"kw0100"}  "$$":[{"#name":"text"  "_":"stereotactic body radiation therapy  SD"}  {"#name":"keyword"  "$":{"id":"kw0110"}  "$$":[{"#name":"text"  "_":"standard deviation  SI"}  {"#name":"keyword"  "$":{"id":"kw0120"}  "$$":[{"#name":"text"  "_":"superior–inferior  XST"}  {"#name":"keyword"  "$":{"id":"kw0130"}  "$$":[{"#name":"text"  "_":"Xsight Spine Tracking
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号