首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Sensitive determination of carnosine in urine by high-performance liquid chromatography using 4-(5,6-dimethoxy-2-phthalimidinyl)-2-methoxyphenylsulfonyl chloride as a fluorescent labeling reagent
Authors:Yasuto Tsuruta  Kiyoshi Maruyama  Hirofumi Inoue  Keiko Kosha  Yuuko Date  Nobuyuki Okamura  Seiji Eto  Eijiro Kojima
Institution:Faculty of Pharmacy and Pharmaceutical Sciences, Fukuyama University, Fukuyama, Hiroshima 729-0292, Japan
Abstract:A simple and highly sensitive high-performance liquid chromatography procedure was developed for the determination of carnosine in urine. Carnosine was derivatized with 4-(5,6-dimethoxy-2-phthalimidinyl)-2-methoxyphenylsulfonyl chloride at 70 °C for 15 min in borate buffer (20 mmol l?1, pH 9.0) to produce fluorescent sulfonamides. After hydrolysis of the reaction mixture with formic acid at 100 °C for 15 min, the fluorescent derivative of carnosine was separated on a reversed-phase column with a linear gradient elution using solvents of (A) acetate buffer (0.1 mmol l?1, pH 7.0) and (B) acetonitrile at a flow-rate of 1.0 ml/min and was detected at excitation and emission wavelengths of 318 and 400 nm, respectively. The detection limit of carnosine was 4 fmol at a signal-to-noise ratio of 3. The within-day and day-to-day relative standard deviations were 2.7–4.6% and 0.4–5.2%, respectively. The concentration of carnosine in normal human urine was found to be 4.6–125 nmol (mg creatinine)?1 (mean ± SD: 21.6 ± 26.6 nmol (mg creatinine)?1, n = 20).
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号