首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Assessment of Long-acting Synthetic Corticotrophin in Hypersensitive Asthmatics and Normal Subjects
Authors:A H El-Shaboury
Abstract:The synthetic polypeptide depot-tetracosactrin (Synacthen-Depot) was given to nine steroid-treated asthmatic patients hypersensitive to animal corticotrophin. Eight had a satisfactory increase in plasma and urinary 17-hydroxycorticosteroids (17-OHCS). The remaining patient had been shown previously to have adrenal suppression. None of the patients developed allergic reactions to depot-tetracosactrin, and seven have been receiving regular injections of the polypeptide twice weekly for the past eight months.In 13 normal subjects intramuscular injections of 1 mg. and 0.5 mg. of depot-tetracosactrin and 40 units of corticotrophin-gel were equally potent in raising the plasma 17-OHCS, but depot-tetracosactrin had a significantly longer action than corticotrophin-gel.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号