首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Adjusted regression trend test for a multicenter clinical trial
Authors:Quan H  Capizzi T
Institution:Clinical Biostatistics, Merck Research Laboratories, Rahway, New Jersey 07065, USA.
Abstract:Studies using a series of increasing doses of a compound, including a zero dose control, are often conducted to study the effect of the compound on the response of interest. For a one-way design, Tukey et al. (1985, Biometrics 41, 295-301) suggested assessing trend by examining the slopes of regression lines under arithmetic, ordinal, and arithmetic-logarithmic dose scalings. They reported the smallest p-value for the three significance tests on the three slopes for safety assessments. Capizzi et al. (1992, Biometrical Journal 34, 275-289) suggested an adjusted trend test, which adjusts the p-value using a trivariate t-distribution, the joint distribution of the three slope estimators. In this paper, we propose an adjusted regression trend test suitable for two-way designs, particularly for multicenter clinical trials. In a step-down fashion, the proposed trend test can be applied to a multicenter clinical trial to compare each dose with the control. This sequential procedure is a closed testing procedure for a trend alternative. Therefore, it adjusts p-values and maintains experimentwise error rate. Simulation results show that the step-down trend test is overall more powerful than a step-down least significant difference test.
Keywords:Closed test procedure  Ordered alternative  P-value adjustment  Two-way design
本文献已被 PubMed 等数据库收录!