首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Detection of complete and partial chromosome gains and losses by comparative genomic in situ hybridization
Authors:Stanislas du Manoir  Michael R Speicher  Stefan Joos  Evelin Schröck  Susanne Popp  Hartmut Döhner  Gyula Kovacs  Michel Robert-Nicoud  Peter Lichter  Thomas Cremer
Institution:(1) Institut für Humangenetik, Im Neuenheimer Feld 328, W-6900 Heidelberg, Germany;(2) Angewandte Tumorvirologie, Deutsches Krebsforschungszentrum, Im Neuenheimer Feld 280, W-6900 Heidelberg, Germany;(3) Medizinische Klinik und Poliklinik V, Universität Heidelberg, Hospitalstr. 3, W-6900 Heidelberg, Germany;(4) Imperial Cancer Research Fund Laboratories, Lincoln's Inn Fields, P.O. Box 123, WC2A 3PX London, UK;(5) Equipe de Reconnaissance de Formes et de Microscopie Quantitative, TIM3, USR CNRS B00690, CERMO, Université Joseph Fourier, Grenoble, France
Abstract:Comparative genomic in situ hybridization (CGH) provides a new possibility for searching genomes for imbalanced genetic material. Labeled genomic test DNA, prepared from clinical or tumor specimens, is mixed with differently labeled control DNA prepared from cells with normal chromosome complements. The mixed probe is used for chromosomal in situ suppression (CISS) hybridization to normal metaphase spreads (CGH-metaphase spreads). Hybridized test and control DNA sequences are detected via different fluorochromes, e.g., fluorescein isothiocyanate (FITC) and tetraethylrhodamine isothiocyanate (TRITC). The ratios of FITC/TRITC fluorescence intensities for each chromosome or chromosome segment should then reflect its relative copy number in the test genome compared with the control genome, e.g., 0.5 for monosomies, 1 for disomies, 1.5 for trisomies, etc. Initially, model experiments were designed to test the accuracy of fluorescence ratio measurements on single chromosomes. DNAs from up to five human chromosome-specific plasmid libraries were labeled with biotin and digoxigenin in different hapten proportions. Probe mixtures were used for CISS hybridization to normal human metaphase spreads and detected with FITC and TRITC. An epifluorescence microscope equipped with a cooled charge coupled device (CCD) camera was used for image acquisition. Procedures for fluorescence ratio measurements were developed on the basis of commercial image analysis software. For hapten ratios 4/1, 1/1 and 1/4, fluorescence ratio values measured for individual chromosomes could be used as a single reliable parameter for chromosome identification. Our findings indicate (1) a tight correlation of fluorescence ratio values with hapten ratios, and (2) the potential of fluorescence ratio measurements for multiple color chromosome painting. Subsequently, genomic test DNAs, prepared from a patient with Down syndrome, from blood of a patient with Tcell prolymphocytic leukemia, and from cultured cells of a renal papillary carcinoma cell line, were applied in CGH experiments. As expected, significant differences in the fluorescence ratios could be measured for chromosome types present in different copy numbers in these test genomes, including a trisomy of chromosome 21, the smallest autosome of the human complement. In addition, chromosome material involved in partial gains and losses of the different tumors could be mapped to their normal chromosome counterparts in CGH-metaphase spreads. An alternative and simpler evaluation procedure based on visual inspection of CCD images of CGH-metaphase spreads also yielded consistent results from several independent observers. Pitfalls, methodological improvements, and potential applications of CGH analyses are discussed.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号