首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Rapid detection of viable Legionella pneumophila in tap water by a qPCR and RT‐PCR‐based method
Authors:R Boss  A Baumgartner  S Kroos  M Blattner  R Fretz  D Moor
Institution:1. Federal Food Safety and Veterinary Office, Berne, Switzerland;2. Food Safety and Veterinary Office, Canton of Basel‐Landschaft, Liestal, Switzerland
Abstract:

Aims

A molecular method for a rapid detection of viable Legionella pneumophila of all serogroups in tap water samples was developed as an alternative to the reference method (ISO). Legionellae are responsible for Legionnaires’ disease, a severe pneumonia in humans with high lethality.

Methods and Results

The developed method is based on a nutritional stimulation and detection of an increase in precursor 16S rRNA as an indicator for viability. For quantification, DNA was detected by qPCR. This method was compared to the ISO method using water samples obtained from public sports facilities in Switzerland. The sensitivity and specificity were 91 and 97%, respectively, when testing samples for compliance with a microbiological criterion of 1000 cell equivalents per l.

Conclusion

The new method is sensitive and specific for Leg. pneumophila and allows results to be obtained within 8 h upon arrival, compared to one week or more by the ISO method.

Significance and Impact of the Study

The method represents a useful tool for a rapid detection of viable Leg. pneumophila of all serogroups in water by molecular biology. It can be used as an alternative to the ISO method for official water analysis for legionellae and particularly when a short test time is required.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号