首页 | 本学科首页   官方微博 | 高级检索  
     


Clinical significance of serum thyroglobulin and antithyroglobulin antibody in differentiated thyroid cancer after thyroid ablation
Authors:Vincze Borbála  Sinkovics István  Keresztes Sándor  Gergye Mária  Boér András  Remenár Eva  Péter Ilona  Szentirmay Zoltán  Kremmer Tibor  Kásler Miklós
Affiliation:Biokémiai Osztály, Országos Onkológiai Intézet, Budapest 1122, Hungary. vincze@oncol.hu
Abstract:Serum thyroglobulin (Tg) is a suitable marker for differentiated thyroid carcinoma following total thyroid ablation. Between 1998 and 2003, serum samples from 715 papillary and 179 follicular tumor patients treated with total/nearly total thyroidectomy and radioiodine ablation therapy were collected. According to the "Guidelines for Oncotherapy in Hungary", serum Tg, antithyroglobulin antibody (TgAb), TSH and FT4 levels were measured in periods of 3 months following the first treatment and of 6 months after 2 years. In the present work the prognostic value of Tg and TgAb data of cancer patients with hormone substitution therapy were evaluated individually and retrospectively. Serum Tg and TgAb concentrations were measured with a highly sensitive immunoradiometric (IRMA) method, and with a second generation, broad epitope specificity competitive radioimmunoassay, respectively. TSH levels determined by fourth generation LIAISON kit were in a range of 0.05-0.10 mIU/L. Accuracy of measuring of Tg <1 ng/ml made it possible to select the low cut-off level (Tg <2 ng/ml) following total thyroidectomy. In the predominant part of TSH-suppressed patients (746/774, 96%) the serum Tg concentration was below the cut-off level of 2 ng/ml. The sensitivity of Tg determination in 59 TSH-suppressed thyroid cancer patients with lung and bone metastases was as high as 86 to 100%. On the contrary, the number of false negative data was high in cases with lymph node metastases of papillary cancer, and sensitivity did not exceed 62%. Specificity and sensitivity of Tg in TgAb negative patients were 91 to 100%. Based on our results it could be concluded that measuring of Tg and TgAb, using a current IRMA method and a second generation RIA kit, proved to be effective tools for the postoperative monitoring of differentiated thyroid tumours. It has to be noted that determination of TgAb is highly recommended for the adequate interpretation of serum Tg levels. Persistently high and/or increasing serum TgAb concentration with low Tg result had a diagnostic value during the follow-up and can be connected with the recurrence or persistence of the differentiated thyroid cancer.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号