首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Flow-induced wall shear stress in abdominal aortic aneurysms: Part II--pulsatile flow hemodynamics
Authors:Finol Ender A  Amon Cristina H
Institution:Mechanical Engineering, Biomedical and Health Engineering, and institute for Complex Engineered Systems, Carnegie Mellon University, Pittsburgh, PA, USA.
Abstract:In continuing the investigation of AAA hemodynamics, unsteady flow-induced stresses are presented for pulsatile blood flow through the double-aneurysm model described in Part I. Physiologically realistic aortic blood flow is simulated under pulsatile conditions for the range of time-average Reynolds numbers 50< or =Re(m) < or =300. Hemodynamic disturbance is evaluated for a modified set of indicator functions which include wall pressure (p(w)), wall shear stress (tau(w)), Wall Shear Stress Gradient (WSSG), time-average wall shear stress (tau(w)*), and time-average Wall Shear Stress Gradient WSSG*. At peak flow, the highest shear stress and WSSG levels are obtained at the distal end of both aneurysms, in a pattern similar to that of steady flow. The maximum values of wall shear stresses and wall shear stress gradients are evaluated as a function of the time-average Reynolds number resulting in a fourth order polynomial correlation. A comparison between numerical predictions for steady and pulsatile flow is presented, illustrating the importance of considering time-dependent flow for the evaluation of hemodynamic indicators.
Keywords:
本文献已被 PubMed 等数据库收录!