首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Ionization fraction of the sputtered metal flux in a hollow cathode magnetron
Authors:Yu P Tsar’gorodtsev  N P Poluektov  I I Usatov  A G Evstigneev  I A Kamyschov
Institution:1. Moscow State Forest University, Pervaya Institutskaya ul. 1, Mytishchi, Moscow oblast, 141005, Russia
Abstract:Results from studies of the parameters of a novel type of plasma source—a hollow cathode magnetron—are presented. The magnetron operates at a gas pressure of 5–20 mTorr, the discharge power being in the range of 0.5–4 kW. At discharge powers exceeding 2 kW, a plasma flow with a density of higher than 1011 cm?3 and length of up to 30 cm forms at the magnetron output. Using a grid quartz crystal microbalance, the ionized copper flux fraction was measured as a function of the gas pressure, discharge power, and distance from the target. At gas pressures of higher than 15 mTorr, the degree of ionization at a distance of 31 cm exceeds 50%.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏