首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Dual-time-point PET/CT study protocol can improve the larynx cancer diagnosis
Institution:1. Poznan University of Medical Sciences, Garbary 15, 61-866 Poznan, Poland;2. Greater Poland Cancer Centre, Garbary 15, 61-866 Poznan, Poland;3. Poznan University of Medical Sciences and the Greater Poland Cancer Center, Garbary 15, 61-866 Poznan, Poland;4. Department of Otolaryngology and Maxillofacial Surgery, University of Zielona Gora, Poland;5. Department of Clinical Psychology, University of Medical Sciences, Poznan, Poland
Abstract:AimTo evaluate whether the sequential dual-time-point fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography (DTP 18F-FDG PET/CT) study improves the differential diagnosis in the larynx.BackgroundIn some cases, the clinical and metabolic similarity of laryngitis and larynx cancer make differential diagnostics difficult when performing standard 18F-FDG PET/CT examinations; therefore, an additional study protocol performance seems to be of reasonable value.Materials and methods90 patients (mean age: 61 ± 11 years, range: 41–84 years): 23 women (mean age: 63 ± 10 years, range: 51–84 years) and 67 men (mean age: 61 ± 11 years, range: 41–80 years) underwent delayed 18F-FDG PET/CT examinations at 60 and 90 min post intravenous injection (p.i.) of the radiopharmaceutical 18F-FDG. We compared the metabolic activity of 90 structures divided into following groups: normal larynx (30 patients), laryngitis (30 lesions) and larynx cancer (30 tumors) with maximal and mean standardized uptake value (SUVmax, SUVmean) and the retention index (RI-SUVmax). We used the receiver operating characteristics (ROC) curve to evaluate the SUVmax cut-off values.ResultsThe SUVmax cut-off value at 60 and 90 min p.i. of 2.3 (sensitivity/specificity: 96.4%/100%) and 2.4 (94.2%/100%), respectively, distinguished normal and abnormal metabolic activity in the larynx. When laryngitis and tumors were compared, the SUVmax cut-off values obtained after initial and delayed imaging were 3.6 (87.5%/52.0%) and 6.1 (58.3%/84%), respectively. The RI-SUVmax of 1.3% (71.4%/88.1%) suggested abnormality, while RI-SUVmax of 6.6%, malignant etiology (75.0%/80.0%).ConclusionsIn this study, the sequential DTP scanning protocol improved the sensitivity and specificity of the PET/CT method in terms of differential diagnosis within the larynx.
Keywords:18F fluorodeoxyglucose  Positron emission tomography  Larynx cancer
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号