首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Hemodynamic investigation of a patient-specific abdominal aortic aneurysm with iliac artery tortuosity
Authors:Yue Qiu  Ding Yuan  Ye Wang  Jun Wen
Institution:1. Department of Applied Mechanics, Sichuan University, Chengdu, China;2. Department of Vascular Surgery, West China Hospital, Sichuan University, Chengdu, China;3. School of Civil Engineering and Architecture, Southwest University of Science and Technology, Mianyang, China
Abstract:Abstract

This paper describes a systematic investigation on the hemodynamic environment in a patient-specific AAA with tortuous common iliac artery(CIA) and external iliac artery (EIA). 3D reconstructions from CT scans and subsequent computational simulation are carried out. It is found out that the Newtonian and non-Newtonian models have very similar flow field and WSS distribution. More importantly, it is revealed that the torturous CIA maintained its helical flow. It is concluded that the assumption of Newtonian blood is adequate in capturing the intra-aneurysmal hemodynamics. Moreover, it is speculated that the physiological spiral flow protects the twisted CIA from the thrombosis formation.
Keywords:CFD  hemodynamics  abdominal aortic aneurysm  iliac tortuosity  thrombosis
设为首页 | 免责声明 | 关于勤云 | 加入收藏