首页 | 本学科首页   官方微博 | 高级检索  
     


Geometrical optimisation of a biochip microchannel fluidic separator
Authors:Xiangdong Xue  Mayur K. Patel  Chris Bailey  Marc P.Y. Desmulliez
Affiliation:1. School of Computing and Mathematical Sciences, University of Greenwich , London , SE10 9LS , UK x.xue@gre.ac.uk;3. School of Computing and Mathematical Sciences, University of Greenwich , London , SE10 9LS , UK;4. MIcroSystems Engineering Centre (MISEC), School of Engineering &5. Physical Sciences, Heriot-Watt University , Edinburgh , EH14 4AS , UK
Abstract:This article reports on the geometric optimisation of a T-shaped biochip microchannel fluidic separator aiming to maximise the separation efficiency of plasma from blood through the improvement of the unbalanced separation performance among different channel bifurcations. For this purpose, an algebraic analysis is firstly implemented to identify the key parameters affecting fluid separation. A numerical optimisation is then carried out to search the key parameters for improved separation performance of the biochip. Three parameters, the interval length between bifurcations, the main channel length from the outlet to the bifurcation region and the side channel geometry, are identified as the key characteristic sizes and defined as optimisation variables. A balanced flow rate ratio between the main and side channels, which is an indication of separation effectiveness, is defined as the objective. It is found that the degradation of the separation performance is caused by the unbalanced channel resistance ratio between the main and side channel routes from bifurcations to outlets. The effects of the three key parameters can be summarised as follows: (a) shortening the interval length between bifurcations moderately reduces the differences in the flow rate ratios; (b) extending the length of the main channel from the main outlet is effective for achieving a uniformity of flow rate ratio but ineffective in changing the velocity difference of the side channels and (c) decreasing the lengths of side channels from upstream to downstream is effective for both obtaining a uniform flow rate ratio and reducing the differences in the flow velocities between the side branch channels. An optimisation process combining the three parameters is suggested as this integration approach leads to fast convergent process and also offers flexible design options for satisfying different requirements.
Keywords:blood fluid separation  microfluidic device  design optimisation  cross flow filtration  modelling and simulation
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号