Abstract: | A method is described for frequent sequential blood volume estimation in baboons using 32P for red cell volume measurements and 125I-albumin for simultaneous plasma volume measurements. Values for red cell, plasma, and total blood volumes are reported. Close correlations of the volumes to bodyweight were demonstrated. Circulatory half-lives of the isotopes, determined from disappearance curves, confirmed their suitability for serial measurements in these baboons. |