首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Chemometrics models for overcoming high between subject variability: applications in clinical metabolic profiling studies
Authors:Yun Xu  Stephen J Fowler  Ardeshir Bayat  Royston Goodacre
Institution:1. Manchester Institute of Biotechnology & School of Chemistry, University of Manchester, Manchester, UK
2. Manchester Academic Health Science Centre, University of Manchester, Manchester, UK
3. NIHR Respiratory and Allergy Clinical Research Facility, University Hospital of South Manchester, Manchester, UK
4. Lancashire Teaching Hospitals NHS Foundation Trust, Preston, UK
5. Plastic & Reconstructive Surgery Research, Manchester Institute of Biotechnology, University of Manchester, Manchester, UK
Abstract:In human metabolic profiling studies, between-subject variability is often the dominant feature and can mask the potential classifications of clinical interest. Conventional models such as principal component analysis (PCA) are usually not effective in such situations and it is therefore highly desirable to find a suitable model which is able to discover the underlying pattern hidden behind the high between-subject variability. In this study we employed two clinical metabolomics data sets as the testing grounds, in which such variability had been observed, and we demonstrate that a proper choice of chemometrics model can help to overcome this issue of high between-subject variability. Two data sets were used to represent two different types of experiment designs. The first data set was obtained from a small-scale study investigating volatile organic compounds (VOCs) collected from chronic wounds using a skin patch device and analysed by thermal desorption-gas chromatography-mass spectrometry. Five patients were recruited and for each patient three sites sampled in triplicate: healthy skin, boundary of the lesion and top of the lesion, the aim was to discriminate these three types of samples based on their VOC profile. The second data set was from a much larger study involving 35 healthy subjects, 47 patients with chronic obstructive pulmonary disease and 33 with asthma. The VOCs in the breath of each subject were collected using a mask device and analysed again by GC–MS with the aim of discriminating the three types of subjects based on breath VOC profiles. Multilevel simultaneous component analysis, multilevel partial least squares for discriminant analysis, ANOVA-PCA, and a novel simplified ANOVA-PCA model—which we have named ANOVA-Mean Centre (ANOVA-MC)—were applied on these two data sets. Significantly improved results were obtained by using these models. We also present a novel validation procedure to verify statistically the results obtained from those models.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号