首页 | 本学科首页   官方微博 | 高级检索  
     


Quantitative determination of azithromycin in plasma, blood and isolated neutrophils by liquid chromatography using pre-column derivatization with 9-fluorenylmethyloxycarbonyl-chloride and fluorescence detection
Authors:Wilms Erik  Trumpie Henk  Veenendaal Wim  Touw Daan
Affiliation:The Hague Central Hospital Pharmacy, Escamplaan 900, The Hague 2504 AC, The Netherlands. e.wilms@ahz.nl
Abstract:In this study, a high-performance liquid chromatographic method with pre-column derivatization and fluorescence detection was optimised and validated for the quantification of azithromycin (AZM) in plasma. Clarithromycin (CLM) was used as an internal standard. Pre-column derivatization was done with 9-fluorenylmethyloxycarbonyl-chloride. Recovery from blood and polymorphonuclear neutrophils (PMNNs) isolated by a gravity separation procedure was also assessed. Analytical separation was carried out using a C18 column as stationary phase and acetonitril-phosphatebuffer as mobile phase. Peak quantification was carried out by excitation at 26 7 nm and detection at 317 nm. A lower limit of quantitation of 0.042+/-0.017 mg/l in plasma, 0.119+/-0.065 mg/l in blood and 0.072+/-0.036 in water was achieved. Linearity was assessed from 0 to 1.5mg/l in plasma and blood and from 0-9 mg/l in water. The analytical method proved to be applicable in a pharmacokinetic study of AZM in a Cystic Fibrosis patient.
Keywords:Azithromycin  Derivatization  LC
本文献已被 ScienceDirect PubMed 等数据库收录!