Reliability of surface EMG measurements over 12 hours.
Authors:Ruth S Ochia  Peter R Cavanagh
Institution:Department of Orthopedic Surgery, Rush University Medical Center, 600 S. Paulina St., 761A Armour Academic Center, Chicago, IL 60612, USA.
Abstract:Bone and muscle are both compromised during long-term space flight. Experiments are, therefore, in progress using surface electromyography (EMG) and joint angle measurements to compare muscle action on earth and in space over complete working days. To date, there is little information on the reliability of such long-term EMG measurements available in the literature. Therefore, the current study determined the reliability and feasibility of using surface EMG over a 12-h interval. Ten young subjects performed standardized isometric exercises at 30% of maximum voluntary effort every 2h throughout a normal working day, which included a period of self-chosen exercise. Surface electrodes remained in place over the biceps brachii (BB), vastus medialis (VM), and gastrocnemius (GN) throughout the day. The normalized integrated EMG for two of the three muscles showed no significant changes during the 12-h period, and only the first observation for VM showed a trend (p<0.1) of differences with three of the other measurement periods. The stability of surface EMG measurements over the 12-h period suggests that this methodology is feasible for use in future long-term EMG studies.