首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Systematic Cross-biospecimen Evaluation of DNA Extraction Kits for Long- and Short-read Multi-metagenomic Sequencing Studies
Authors:Jacqueline Rehner  Georges Pierre Schmartz  Laura Groeger  Jan Dastbaz  Nicole Ludwig  Matthias Hannig  Stefan Rupf  Berthold Seitz  Elias Flockerzi  Tim Berger  Matthias Christian Reichert  Marcin Krawczyk  Eckart Meese  Christian Herr  Robert Bals  Sren L Becker  Andreas Keller  Rolf Müller  The IMAGINE Consortium
Institution:1. Institute of Medical Microbiology and Hygiene, Saarland University, D-66421 Homburg, Germany;2. Clinical Bioinformatics, Saarland University, D-66123 Saarbrücken, Germany;3. Department of Human Genetics, Saarland University, D-66421 Homburg, Germany;4. Helmholtz Institute for Pharmaceutical Research Saarland, D-66123 Saarbrücken, Germany;5. Clinic of Operative Dentistry, Periodontology and Preventive Dentistry, Saarland University, D-66421 Homburg, Germany;6. Department of Ophthalmology, Saarland University Medical Center, D-66421 Homburg, Germany;7. Department of Medicine II, Saarland University Medical Center, D-66421 Homburg, Germany;8. Department of Internal Medicine V – Pulmonology, Allergology, Intensive Care Medicine, Saarland University, D-66421 Homburg, Germany
Abstract:High-quality DNA extraction is a crucial step in metagenomic studies. Bias by different isolation kits impairs the comparison across datasets. A trending topic is, however, the analysis of multiple metagenomes from the same patients to draw a holistic picture of microbiota associated with diseases. We thus collected bile, stool, saliva, plaque, sputum, and conjunctival swab samples and performed DNA extraction with three commercial kits. For each combination of the specimen type and DNA extraction kit, 20-gigabase (Gb) metagenomic data were generated using short-read sequencing. While profiles of the specimen types showed close proximity to each other, we observed notable differences in the alpha diversity and composition of the microbiota depending on the DNA extraction kits. No kit outperformed all selected kits on every specimen. We reached consistently good results using the Qiagen QiAamp DNA Microbiome Kit. Depending on the specimen, our data indicate that over 10 Gb of sequencing data are required to achieve sufficient resolution, but DNA-based identification is superior to identification by mass spectrometry. Finally, long-read nanopore sequencing confirmed the results (correlation coefficient > 0.98). Our results thus suggest using a strategy with only one kit for studies aiming for a direct comparison of multiple microbiotas from the same patients.
Keywords:Whole-genome analysis  Comparative genomics  Short-read sequencing  Long-read sequencing  DNA extraction  Metagenomics
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号