首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Microbiological Contamination of Hospital Air: I. Quantitative Studies
Authors:V W Greene  D Vesley  R G Bond  and G S Michaelsen
Abstract:The levels of airborne contamination in various areas of two hospitals were determined during a 15-month sampling period, using Casella and Andersen volumetric samplers. Based on nearly 5,000 samples, the mean count per ft3 ranged from 4.5 in obstetric-gynecology delivery rooms to 72.4 in waste-handling areas. The mean count for the entire hospital environment was on the order of 20 contaminants per ft3; 48% were associated with particles >5 μ diam, 30% with particles between 2 and 6 μ diam, and 22% with particles <2 μ diam. The airborne contamination was influenced by traffic, activity, ventilation considerations, and gross surface contamination, but not markedly by seasonal changes. When suitable control measures were implemented, the level of contamination could be diminished and kept low.