首页 | 本学科首页   官方微博 | 高级检索  
   检索      


The Fluorescent Antibody Technique for the Detection of Salmonella in Routine Use
Authors:P A Gibbs    J T Patterson  J G Murray
Institution:Ministry of Agriculture for Northern Ireland and The Queen's University, Elmwood Avenue, Belfast BT9 6BB Northern Ireland
Abstract:S ummary : The direct and indirect fluorescent antibody technique (FAT) were compared with cultural methods for detecting salmonellae in meat products, animal feedingstuffs, poultry carcase swabs, giblets and poultry plant and equipment swabs. Salmonellae were not isolated from meat products and fluorescent cells were not seen on slides prepared by either FAT. The indirect and direct FAT recorded 13% and 9% respectively, false positive results, with samples of animal feedingstuffs, but the direct FAT recorded a single false negative result. Salmonellae were not isolated from poultry carcase swabs but 3% and 4·5% respectively, of false positive results were obtained with the indirect and direct FAT. Salmonellae were isolated from both giblet samples and poultry plant swabs and both gave rise to false negative FAT results. Preliminary studies of the efficacy of the FAT for screening animal faecal material for salmonellae indicated that no single combination of enrichment broth and FAT gives unequivocal results, but the staining of smears from tetrathionate broth by either FAT gives rise to a high percentage of false negative results.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏