首页 | 本学科首页   官方微博 | 高级检索  
     


Quantification of Lawsonia intracellularis in porcine faeces by real‐time PCR
Authors:H. Nathues  K. Holthaus  E. Grosse Beilage
Affiliation:Field Station for Epidemiology, University of Veterinary Medicine, Foundation, Hannover, Germany
Abstract:Aim: To develop and to validate a method for the quantification of Lawsonia intracellularis in porcine faeces by real‐time PCR. Methods and Results: A real‐time PCR including a calibrator based on plasmid DNA for quantification by means of ΔΔCt method was evaluated. The parameters specificity, detection limit, quantification limit, linearity, range, repeatability, precision and recovery were validated. The detection limit of the agent was 1 copy per reaction, and quantification was reliable between 101 and 107 copies per μl reaction volume. The linearity calculated by logistic regression revealed a slope of ?3·329 reflecting an efficiency of 99·7% for the assay. Moreover, it was shown that storage of samples and repetition of tests including DNA isolation by same or other investigators did not influence the outcome. Conclusion: The quantification method described herein revealed consistent results for the quantitation of L. intracellularis in porcine faeces samples. Significance and Impact of the Study: In contrast to common PCR in combination with gel electrophoresis, this validated quantification method based on real‐time PCR enhances a reliable quantification and is even more sensitive.
Keywords:ileitis  Lawsonia intracellularis  real‐time PCR  swine  validation