A continuous-flow high-yield process for preparation of lipid-free hemoglobin
Authors:J R DeLoach  C L Sheffield  G E Spates
Abstract:Hypotonic hollow-fiber dialysis of bovine red blood cells followed by ultrafiltration through 0.1-micron pore hollow fibers provides a simple method for isolation of lipid-free hemoglobin. Hemoglobin (Hb) isolated by comparative techniques were all contaminated with membrane stroma. HPLC analysis of Hb revealed a protein peak of 99.6% purity and sodium dodecylsulfate-polyacrylamide gel electrophoresis analysis revealed a single band. The process requires hypoosmotic dialysis of bovine RBC to a final 160-180 mosmol/kg osmotic pressure. Additional reduction in osmotic pressure causes irreversible cell lysis which leads to lipid contamination of the Hb. Processing of 1/2 liter of packed red blood cells requires 4-5 h, resulting in an average of 90% hemoglobin recovery.