首页 | 本学科首页   官方微博 | 高级检索  
     


The effects of RF absorbers on exposure levels at 100 MHz
Authors:Allen Stewart J  Mylacraine Kevin S
Affiliation:General Dynamics Advanced Information Systems, Brooks City-Base, Texas 78235, USA. stujallen@peoplepc.com
Abstract:The study presented in this article was designed to complete a dosimetry protocol required to establish the RF exposure levels at 100 MHz for measurement of the effect on cognition in human volunteers near the resonant frequency in seated positions. The results are compared with those reported previously using the same experimental procedures, except with the vertically radiating dipole antenna and corner reflector raised by .30 m to the vertical center of the anechoic chamber. The average whole body SAR for the high and low SAR conditions used in the previous study was achieved with a 12% increase in transmitter forward power. However, the incident power density averaged over the body was increased by 42%, from 40 and 80 W/m(2) in the previous study to 57 and 113 W/m(2) in the current study to achieve the same whole body average SAR used in the previous study. The differences in field patterns and field intensities between the previous and current studies were introduced by interactions between the E-field and RF absorbers in the floor and ceiling, which represent resonant structures at 100 MHz.
Keywords:human whole body resonance  absorber resonance  whole body specific absorption rate (SAR)
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏