首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Optimisation of agitation and aeration in fermenters
Authors:S S Alves  J M T Vasconcelos
Institution:(1) Dept. of Chemical Engineering, Instituto Superior Técnico, 1096 Lisboa-Codex, Portugal
Abstract:The problem of optimising agitation and aeration in a given fermenter is addressed. The objective function is total electric power consumed for agitation, compression and refrigeration. The major constraint considered is to ensure that the dissolved oxygen concentration is above the critical value. It is shown that it is possible to analytically calculate the optimal pair (air flowrate, stirrer speed) and that, at least for the industrial antibiotics fermentation used as case-study, the optimum lies within a window for satisfactory operation, limited by other possible constraints to the problem. Savings achievable by optimal operation as compared with current industrial procedure were found to be around 10% at pilot plant scale (0.26 m3) and 20% at full scale (85 m3).List of Symbols A fermenter cross sectional area (m2) - C dissolved oxygen concentration (mole m–3) - C * DO concentration in equilibrium with the gas (mole m–3) - C crit critical DO concentration (mole m–3) - C p specific heat of air at constant pressure (J kg–1 K–1) - C sp dissolved oxygen set point (mole m–3) - C v specific heat of air at constant volume (J kg–1 K–1) - D agitator diameter (m) - f pressure correction of air flow-rate - (Fl g)F aeration number at flooding - (Fr g)F froude number at flooding - k coefficient in expression for mass transfer coefficient - K La volumetric oxygen transfer coefficient (s–1) - m power exponent in expression for mass transfer coefficient - n gas flow rate exponent in expression for mass transfer coefficient - n * number of impellers - N rotation speed (s–1) - N F rotation speed at flooding (s–1) - N p unaerated power number - N pg aerated power number - OUR Oxygen Uptake Rate (mole m–3 s–1) - p 0 atmospheric pressure (N m–2) - p 1 compressor exit pressure (N m–2) - p 2 pressure at the bottom of the fermenter (N m–2) - p 3 pressure at the top of the fermenter (N m–2) - P c compression power (W) - P d power added by expansion (W) - P ev power removed by evaporation (W) - P g agitation power (W) - P m power added by metabolism (W) - P r power removed by refrigeration (W) - P t total power (W) - Q air flow-rate at atmospheric conditions (m3 s–1) - Q f air flow-rate at average fermenter conditions (m3 s–1) - s 0 absolute humidity at atmospheric conditions - s 3 absolute humidity at fermenter exit - T tank diameter (m) - V liquid volume (m3) - v s gas superficial velocity (m s–1) - agr i parameter defined in the text - beta safety margin for dissolved oxygen (mole m–3) - gamma ratio of specific heats of air - eegr g agitation efficiency - eegr c compression efficiency - eegr r refrigeration efficiency - rhov liquid density (kg m–3) - rhov g air density (kg m–3) - lambda latent heat of vaporisation of water (J kg–1) The authors are grateful to Elsa Silva, Carlos Lopes, Carlos Aguiar, Fernando Mendes, and Alexandre Cardoso, who helped with parts of this work, and to CIPAN for permission to publish these data.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号