全文获取类型
收费全文 | 268篇 |
免费 | 20篇 |
国内免费 | 6篇 |
出版年
2023年 | 3篇 |
2022年 | 8篇 |
2021年 | 7篇 |
2020年 | 9篇 |
2019年 | 12篇 |
2018年 | 14篇 |
2017年 | 9篇 |
2016年 | 3篇 |
2015年 | 7篇 |
2014年 | 22篇 |
2013年 | 16篇 |
2012年 | 11篇 |
2011年 | 16篇 |
2010年 | 14篇 |
2009年 | 16篇 |
2008年 | 11篇 |
2007年 | 26篇 |
2006年 | 14篇 |
2005年 | 18篇 |
2004年 | 9篇 |
2003年 | 10篇 |
2002年 | 3篇 |
2001年 | 2篇 |
2000年 | 4篇 |
1999年 | 3篇 |
1998年 | 3篇 |
1997年 | 4篇 |
1996年 | 2篇 |
1995年 | 3篇 |
1994年 | 5篇 |
1992年 | 1篇 |
1991年 | 2篇 |
1990年 | 1篇 |
1989年 | 1篇 |
1988年 | 1篇 |
1985年 | 1篇 |
1984年 | 1篇 |
1980年 | 2篇 |
排序方式: 共有294条查询结果,搜索用时 531 毫秒
1.
Minjuan Shen Mingli Lin Mengqi Zhu Wenxin Zhang Danyang Lu Huanhuan Liu Jingjing Deng Kehua Que Xu Zhang 《Biochimica et Biophysica Acta (BBA)/General Subjects》2019,1863(1):167-181
Since their discovery, matrix vesicles (MVs) containing minerals have received considerable attention for their role in the mineralization of bone, dentin and calcified cartilage. Additionally, MVs' association with collagen fibrils, which serve as the scaffold for calcification in the organic matrix, has been repeatedly highlighted. The primary purpose of the present study was to establish a MVs–mimicking model (PEG-S-ACP/micelle) in vitro for studying the exact mechanism of MVs-mediated extra/intra fibrillar mineralization of collagen in vivo. In this study, high-concentration serine was used to stabilize the amorphous calcium phosphate (S-ACP), which was subsequently mixed with polyethylene glycol (PEG) to form PEG-S-ACP nanoparticles. The nanoparticles were loaded in the polysorbate 80 micelle through a micelle self-assembly process in an aqueous environment. This MVs–mimicking model is referred to as the PEG-S-ACP/micelle model. By adjusting the pH and surface tension of the PEG-S-ACP/micelle, two forms of minerals (crystalline mineral nodules and ACP nanoparticles) were released to achieve the extrafibrillar and intrafibrillar mineralization, respectively. This in vitro mineralization process reproduced the mineral nodules mediating in vivo extrafibrillar mineralization and provided key insights into a possible mechanism of biomineralization by which in vivo intrafibrillar mineralization could be induced by ACP nanoparticles released from MVs. Also, the PEG-S-ACP/micelle model provides a promising methodology to prepare mineralized collagen scaffolds for repairing bone defects in bone tissue engineering. 相似文献
2.
Andreas Barth 《BBA》2007,1767(9):1073-1101
This review discusses the application of infrared spectroscopy to the study of proteins. The focus is on the mid-infrared spectral region and the study of protein reactions by reaction-induced infrared difference spectroscopy. 相似文献
3.
An artificial osmotic cell: a model system for simulating osmotic processes and for studying phenomena of negative pressure in plants 总被引:3,自引:1,他引:2
Abstract An artificial osmotic cell has been constructed using reverse osmosis membranes. The cell consisted of a thin film of an osmotic solution (thickness: 100 to 200 μm) containing a non-permeating solute and was bounded between the membrane and the front plate of a pressure transducer which continuously recorded cell turgor. The membrane was supported by metal grids to withstand positive and negative pressures (P). At maximum, negative pressures of up to –0.7 MPa (absolute) could be created within the film on short-term and pressures of up to –0.3 MPa could be maintained without cavitation for several hours. As with living plant cells, the application of osmotic solutions of a non-permeating solute resulted in monophasic relaxations of turgor pressure from which the hydraulic conductivity of the membrane (Lp) and the elastic modulus of the cell (?) could be estimated. The application of solutions with permeating solutes resulted in biphasic pressure relaxation curves (as for living cells) from which the permeability (Ps) and reflection (σs) coefficients could be evaluated for the given membrane. Lp, Ps, and σs were independent of P and did not change upon transition from the positive to the negative range of pressure. It is concluded that the artificial cell could be used to simulate certain transport properties of living cells and to study phenomena of negative pressure as they occur in the xylem and, perhaps, also in living cells of higher plants. 相似文献
4.
Martin M. Lee Francis H.Y. Green W.Michael Schoel Samuel Schürch 《生物化学与生物物理学报:疾病的分子基础》1994,1226(2):151-162
Cell-substrate adhesion was quantified for two cultured mesothelioma cell lines (epitheliomatus and sarcomatous) on glass, fibronectin and laminin substrates. Interference reflection microscopy (IRM) was used to image the adhesion patterns of cells and a grey level analysis was employed to quantify adhesion. Sarcomatous cells demonstrated marked adhesion to glass and fibronectin-coated substrates but not to laminin-coated substrate, with the greatest adhesion occurring on the fibronectin-coated surface. This adhesion was accompanied by cytoplasmic spreading. By contrast, epitheliomatous cells showed little tendency to adhere to any of the substrates and only showed significant spreading when in contact with the laminin substrate (P < 0.01). A bioassay was used to determine the metastatic potential of each of the cell lines. Via the intravenous route, the sarcomatous cells killed the host rats in 24.7 ± 1.5 (S.D.) days compared to 27.3 ± 0.9 (S.D.) days for the epitheliomatous cells (P < 0.01). After subcutaneous inoculation of tumour cells, the sarcomatous cells killed the host rats in 54.7 ± 0.7 (S.D.) days compared to 48.5 ± 0.5 (S.D.) days for the epitheliomatous cells (P < 0.01). We conclude that the results of the metastasis bioassays were consistent with the predicted behavior of these cell lines based on their ability to adhere to substrates in the in vitro adhesion assays. 相似文献
5.
Junichiro J. Kazama Takashi Aikata Masaaki Arakawa Hidehiro Ozawa 《Biotechnic & histochemistry》1994,69(6):324-328
We describe a new technique for immunohistochemical and enzyme-histochemi-cal double staining using confocal laser scanning microscopy in the reflection mode. As an example, we investigated the immunoreactivity for Spot 35-calbindin-D28K, a vitamin D-dependent calcium binding protein, and the enzyme activity for ma+-ATPase in the rat kidney. The lead precipitation method for Ca2+-ATPase was initially used to process kidney slices. Each specimen was then dehydrated and embedded in a water soluble resin. Thin sections were cut from the resin block, and an indirect immunocolloidal gold method with silver enhancement for Spot 35-calbindin-D28K antigen was carried out on the glass slides. Results were then observed by confocal laser scanning microscopy in the reflection mode. The three-dimensional distribution of the reaction products was detected by serial optic slice images. Lead phosphate particles, which represented the location of Ca2+-ATPase, were distributed deep in the section. The most intense signals from the silver partkles were detected from the surface slice of the section. A stereoscopic image generated from the serial optic slices clearly showed the differences in their distribution. 相似文献
6.
BackgroundTrace elements exhibit essential functions in many physiological processes. Thus, for research focusing on trace element homeostasis and metabolism analytical methods allowing for multi-element analyses are fundamental. Small sample amounts may be a big challenge in trace element analyses especially if also other end points want to be addressed in the same sample. Therefore, the aim of the present study was to examine trace elements (iron, copper, zinc, and selenium) in murine liver tissue prepared by a RIPA buffer-based lyses method.Methods and resultsAfter centrifugation, lysates and pellets were obtained and trace elements were analyzed with TXRF in liver lysates. The results were compared to that obtained by a standard microwave-assisted acidic digestion with subsequent ICP-MS/MS analysis of the same liver tissue, liver lysates, and remaining pellets. In addition, trace element concentrations, determined in murine serum with both methods, were compared. For serum samples, both TXRF and ICP-MS/MS provide similar and highly correlating results. Furthermore, in liver lysate samples prepared with RIPA buffer, comparable trace element concentrations were measured by TXRF as with the standard digestion technique and ICP-MS/MS. Only marginal amounts of trace elements were detected in the pellets.ConclusionTaken together, the results obtained by the present study indicate that the RIPA buffer-based method is suitable for sample preparation for trace element analyses via TXRF, at least for the here investigated murine liver samples. 相似文献
7.
Klaus Lunau 《Plant Systematics and Evolution》1995,198(3-4):235-252
The spectral reflection of pollen in 67 plant species out of 28 families was measured by means of mass recording of pollen grains. Various types of spectral reflection curves were found, but 75% belonged to two categories: 1. Human-yellow pollen with strong reflection in the green and red, and low reflection in the ultraviolet and blue range of wavelengths. 2. Human-whitish pollen with strong reflection in the green and red and additional reflection of shorter wavelengths. It is shown that it is important to have information about the mode of the visual pollen display — crypsis or colour contrast against the corolla, pollen advertisement, or concealment — and the visual capabilities of the presumed pollinators in order to be able to discuss the signalling function of pollen colours. 相似文献
8.
《Cell communication & adhesion》2013,20(2):17-23
AbstractInteraction of integrins with extracellular matrices is essential for cell adhesion to substrata. Ventral surfaces of fibroblasts adhering to flat substrata are not flat but have uneven 3D topology. However, spatial relationship between the topology of the ventral cell surface and arrangement of extracellular matrix fibrils remains unclear. Here, we report a novel and simple method based on total internal reflection fluorescence microscopy to quantify the distance between the ventral plasma membrane and the glass substratum. We observe that the distance varies from <?25 nm at focal adhesions to 40–50 nm at close contacts and >?80 nm in other regions. Furthermore, by applying this novel method, we show that fibronectin fibrils are also separated from the substratum in regions where the ventral cell surface-substratum distance is >?80 nm. Our results reveal that fibronectin fibrils are not simply adsorbed to the glass substratum but follow the ventral cell surface topology. 相似文献
9.
Florian Capito Romas Skudas Bernd Stanislawski Harald Kolmar 《Biotechnology progress》2013,29(1):265-274
Production of recombinant proteins, e.g. antibodies, requires constant real‐time monitoring to optimize yield and quality attributes and to respond to changing production conditions, such as host cell protein (HCP) titers. To date, this monitoring of mammalian cell culture‐based processes is done using laborious and time consuming enzyme‐linked immunosorbent assays (ELISA), two‐dimensional sodium dodecylsulphate polyacrylamide gel electrophoresis, and chromatography‐based systems. Measurements are usually performed off‐line, requiring regular sample withdrawal associated with increased contamination risk. As information is obtained retrospectively, the reaction time to adapt to process changes is too long, leading to lower yield and higher costs. To address the resulting demand for continuous online‐monitoring systems, we present a feasibility study using attenuated total reflection spectroscopy (ATR) to monitor mAb and HCP levels of NS0 cell culture in situ, taking matrix effects into account. Fifty‐six NS0 cell culture samples were treated with polyelectrolytes for semi‐selective protein precipitation. Additionally, part of the samples was subjected to filtration prior to analysis, to change the background matrix and evaluate effects on chemometric quantification models. General models to quantify HCP and mAb in both filtered and unfiltered matrix showed lower prediction accuracy compared to models designed for a specific matrix. HCP quantification in the range of 2,000–55,000 ng mL?1 using specific models was accurate for most samples, with results within the accepted limit of an ELISA assay. In contrast, mAb prediction was less accurate, predicting mAb in the range of 0.2–1.7 g L?1. As some samples deviated substantially from reference values, further investigations elucidating the suitability of ATR for monitoring are required. © 2012 American Institute of Chemical Engineers Biotechnol. Prog., 2013 相似文献
10.
Markus Ernstberger Pascal Boeswetter Tobias Baselt Frank Ebert Fabiola Basan Hanno Steinke Niels Hammer Ronny Grunert Peter Hartmann 《Journal of biophotonics》2013,6(4):310-313
Thin slices of human tissues are characterized concerning reflection and transmission in a wavelength range from 400 to 1700 nm. The results are primarily useful to find a wavelength for the detection of subjacent blood vessels during surgical procedures, especially neurological surgery. The measurements have been conducted using a customized measuring station, utilizing two halogen bulb lamps and two spectrometers. This paper focuses on creating a data base with the optical properties of artery, brain, bone, nasal mucosa, and nerve. The spectral distributions are compared among each other, similarities and differences are pointed out. Each tissue has got unique spectral characteristics, whereas typical absorption bands can be found in the overall tissues, especially hemoglobin and water absorption bands. The reflectivity maxima are typically located in the red or near‐infrared. All the transmission maxima are located between 1075 nm and 1100 nm. The measurements have been conducted at the Institute of Anatomy at the University of Leipzig. (© 2013 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim) 相似文献