首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   101篇
  免费   5篇
  国内免费   3篇
  2022年   1篇
  2021年   5篇
  2020年   4篇
  2019年   7篇
  2018年   4篇
  2017年   12篇
  2016年   6篇
  2015年   5篇
  2014年   6篇
  2013年   25篇
  2012年   6篇
  2011年   6篇
  2010年   1篇
  2009年   4篇
  2008年   4篇
  2007年   4篇
  2006年   1篇
  2005年   2篇
  2003年   1篇
  2002年   1篇
  2001年   1篇
  2000年   1篇
  1988年   1篇
  1987年   1篇
排序方式: 共有109条查询结果,搜索用时 15 毫秒
1.
Prostate cancer is the most common malignancy in men and the second leading cause of cancer-related death in men. Radiotherapy is a curative option that is administered via external beam radiation, brachytherapy, or in combination. Sexual dysfunction is a common toxicity following radiotherapy, similar to men undergoing radical prostatectomy, but the etiology is different. The pathophysiology of radiation-induced sexual dysfunction is multi-factorial, and the toxicity is a major cause of impaired quality of life among long-term prostate cancer survivors. Management of a patient’s sexual function during and after radiotherapy requires multidisciplinary coordination of care between radiation oncology, urology, psychiatry, pharmacy, and dermatology. This review provides a framework for clinicians to better understand prostatic radiotherapy-induced sexual dysfunction diagnosis, evaluation, and a patient-centered approach to toxicity preventive strategies and management.  相似文献   
2.
Lack of temperature sensation of myoelectric prosthetic hand limits the daily activities of amputees.To this end,a non-invasive temperature sensation method is proposed to train amputees to sense temperature with psychophysical sensory substitution.In this study,22 healthy participants took part besides 5 amputee participants.The duration time of the study was 31 days with five test steps according to the Leitner technique.An adjustable temperature mug and a Peltier were used to change the temperature of the water/phantom digits to induce temperature to participants.Also,to isolate the surround-ings and show colors,a Virtual Reality(VR)glass was employed.The statistical results conducted are based on the response of participants with questionnaire method.Using Chi-square tests,it is concluded that participants answer the experiment significantly correctly using the Leitner technique(P value<0.05).Also,by applying the"Repeated Measures ANOVA",it is noticed that the time of numbness felt by participants had significant(P value<0.001)difference.Participants could remember lowest and highest temperatures significantly better than other temperatures(P value<0.001);furthermore,the well-trained amputee participant practically using the prosthesis with 72.58%could identify object's temperature with only once time experimenting the color temperature.  相似文献   
3.
Abstract

This paper presents the process of designing a new elastic element replacing a membrane in the chamber stapes prosthesis (ChSP). The results of the study are volume displacement characteristics obtained for the prosthesis and physiological stapes. Simulation tests on a 3D CAD model have confirmed that a properly designed ring can stimulate perilymph with the same or greater efficacy as the physiological stapes footplate placed on the elastic annular ligament. The ChSP with a new elastic element creates a good chance of improving hearing in patients suffering from otosclerosis.  相似文献   
4.
It is always recommended to use more implants for supporting a prosthesis in the immediate loading condition than in the classical two-stage treatment procedure. By means of the finite element (FE) method, the influence of the number of implants used in immediately loaded fixed partial prosthesis (FPP) on the load distribution was investigated, considering the abutment geometry. Two 3D FE models were studied employing four implants to support a FPP in the premaxilla. One model was designed with straight abutments and the other with 20°-angled abutments. The results concerning implant displacements, stresses and strains were compared with those of two implant-supported FPPs, obtained in a previous study. A noticeable reduction in the determined biomechanical bone loading was observed with the use of more implants in supporting an immediately loaded prosthesis. This study confirms that the use of additional numbers of implants in an immediately loaded prosthesis is highly recommended.  相似文献   
5.
Tibial bone defect is a critical problem for revision knee arthroplasty. Instead of using metallic spacer or cement, biodegradable scaffolds could be an alternative solution. A numerical model of a revision knee arthroplasty was thus developed to estimate the mechanical resistance of the scaffold in this demanding situation. The tibia, scaffold, and prosthesis were represented by simplified parameterised geometries. The maximal gait cycle force was applied asymmetrically to simulate a critical loading. Several parameters were analysed: 1) inter-individual variability, 2) cortical bone stiffness, 3) cortical bone thickness, 4) prosthesis fixation quality, and 5) scaffold thickness. The calculated scaffold strain was compared to its experimental ultimate strain. Among the tested parameters, failure was only predicted with scaffold thickness below 5 mm. This study suggests that biodegradable bone scaffolds could be used to fill bone defects in revision knee arthroplasty, but scaffold size seems to be the limiting factor.  相似文献   
6.

Laryngectomized patients use indwelling silicone rubber voice prostheses, placed in a surgically created fistula in between the trachea and the esophagus, for voice and speech rehabilitation. At the esophageal side, these voice prostheses rapidly become colonized by a thick biofilm consisting of a variety of oral and skin bacteria and yeasts, and on average, after 3–4 months a prosthesis has to be replaced. In this study, the influence of caffeinated soft drinks on biofilm formation on silicone rubber voice prostheses has been investigated in a modified Robbins device. Robbins devices were first inoculated with the total cultivable microflora from an explanted voice prosthesis for 3 d, after which the devices were perfused three times daily over a 12 day period with 650 ml of either phosphate buffered saline or carbonated mineral water (controls), caffeinated soft drinks (two types), or a decaffeinated and a sugar‐free version of one of the caffeinated soft drinks. At the end of a day, during the experimental period, the devices were filled with growth medium for 30 min. Both caffeinated soft drinks reduced bacterial prevalence in the biofilms to 1–5% of the control, while yeasts thrived in voice prosthetic biofilms exposed to caffeinated soft drinks. Neither the controls, nor the decaffeinated soft drink, nor the sugar‐free version of this showed these effects on bacterial prevalence.  相似文献   
7.
The integrity of biofilms on voice prostheses used to rehabilitate speech in laryngectomized patients causes unwanted increases in airflow resistance, impeding speech. Biofilm integrity is ensured by extracellular polymeric substances (EPS). This study aimed to determine whether synthetic salivary peptides or mucolytics, including N-acetylcysteine and ascorbic acid, influence the integrity of voice prosthetic biofilms. Biofilms were grown on voice prostheses in an artificial throat model and exposed to synthetic salivary peptides, mucolytics and two different antiseptics (chlorhexidine and Triclosan). Synthetic salivary peptides did not reduce the air flow resistance of voice prostheses after biofilm formation. Although both chlorhexidine and Triclosan reduced microbial numbers on the prostheses, only the Triclosan-containing positive control reduced the air flow resistance. Unlike ascorbic acid, the mucolytic N-acetylcysteine removed most EPS from the biofilms and induced a decrease in air flow resistance.  相似文献   
8.
In implantology, when financial or biological feasibility limitations appear, it is necessary to use prostheses with geometries that deviate from the conventional, with a pontic in the absence of an intermediate implant. The aim of this study was analyze and understand the general differences in the stresses generated in implants, components and infrastructures according to the configuration of the prosthesis over three or two implants. Thus, this paper analyzes the von Mises equivalent stresses (VMES) of ductile materials on their external surfaces. The experimental groups: Regular Splinted Conventional Group (RCG), which had conventional infrastructures on 3 regular-length Morse taper implants (4x11?mm); Regular Splinted Pontic Group (RPG), which had infrastructures with intermediate pontics on 2 regular-length Morse taper implants (4x11?mm). The simulations of the groups were created with Ansys Workbench 10.0 software. The results revealed that the RPG presented greater areas of possible fragility due to higher stress concentrations, for example, in the cervical area of the union between the implant and component the top platform of the abutment, as well as greater coverage of the stress by the cervical implant threads. The RPG infrastructure was also more affected by stresses in the connection areas between the prostheses and on the occlusal surface. There is an advantage to using prostheses supported by a greater number of implants (RCG) because this decreases the stress in the analyzed structures and consequently improves stress dissipation to the supporting bone, which would preserve the system.  相似文献   
9.
10.
为研究当前主动型下肢假肢控制问题的解决策略,提出了主动型下肢假肢设计和分类的通用控制框架,包括3个分层结构:上层控制器、中层控制器、底层控制器。其中,上层控制器感知运动意图;中层控制器将运动意图转换为预期的装置状态,用于底层控制器的跟踪参考;底层控制器通过反馈控制或者前馈控制计算出预期装置状态与当前装置状态的误差,驱动假肢执行这些命令,形成控制闭环。结果表明,该通用控制框架可完整阐释主动型下肢假肢的人—机—环境共融关系,明确了分层控制策略的层级任务,为未来主动型下肢假肢的发展提供了理论指导。  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号