首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   7篇
  免费   0篇
  2019年   1篇
  2017年   1篇
  2014年   1篇
  2013年   2篇
  2006年   1篇
  2004年   1篇
排序方式: 共有7条查询结果,搜索用时 15 毫秒
1
1.
The human cervical spine supports substantial compressive load in vivo. However, the traditional in vitro testing methods rarely include compressive loads, especially in investigations of multi-segment cervical spine constructs. Previously, a systematic comparison was performed between the standard pure moment with no compressive loading and published compressive loading techniques (follower load – FL, axial load – AL, and combined load – CL). The systematic comparison was structured a priori using a statistical design of experiments and the desirability function approach, which was chosen based on the goal of determining the optimal compressive loading parameters necessary to mimic the segmental contribution patterns exhibited in vivo. The optimized set of compressive loading parameters resulted in in vitro segmental rotations that were within one standard deviation and 10% of average percent error of the in vivo mean throughout the entire motion path. As hypothesized, the values for the optimized independent variables of FL and AL varied dynamically throughout the motion path. FL was not necessary at the extremes of the flexion–extension (FE) motion path but peaked through the neutral position, whereas, a large negative value of AL was necessary in extension and increased linearly to a large positive value in flexion. Although further validation is required, the long-term goal is to develop a “physiologic” in vitro testing method, which will be valuable for evaluating adjacent segment effect following spinal fusion surgery, disc arthroplasty instrumentation testing and design, as well as mechanobiology experiments where correct kinematics and arthrokinematics are critical.  相似文献   
2.
A number of finite element analyses (FEAs) for the dental implant were performed without regard for preload and with all interfaces ‘fixed-bonded’. The purpose of this study was comparing the stress distributions between the conventional FEA model with all contacting interfaces ‘fixed-bonded’ (bonded model) and the model with the interfaces of the components in ‘contact’ with friction simulated as a preloaded implant (contact model). We further verified the accuracy of the result of the FEA using model experiment. In the contact model, the stress was more widely distributed than in the bonded model. From the model study, the preload induced by screw tightening generated strain at the peri-implant bone, even before the application of external force. As a result, the bonded model could not reproduce the mechanical phenomena, whereas the contact model is considered to be appropriate for analysing mechanical problems.  相似文献   
3.
The role of the alpha-adrenergic system in the control of cardiac preload (central venous blood pressure; P(ven)) and venous capacitance during exercise was investigated in rainbow trout (Oncorhynchus mykiss). In addition, the antihypotensive effect of the renin-angiotesin system (RAS) was investigated during exercise after alpha-adrenoceptor blockade. Fish were subjected to a 20-min exercise challenge at 0.66 body lengths s(-1) (BL s(-1)) while P(ven), dorsal aortic blood pressure (P(da)) and relative cardiac output (Q) was recorded continuously. Heart rate (f(H)), cardiac stroke volume (SV) and total systemic resistance (R(sys)) were derived from these variables. The mean circulatory filling pressure (MCFP) was measured at rest and at the end of the exercise challenge, to investigate potential exercise-mediated changes in venous capacitance. The protocol was repeated after alpha-adrenoceptor blockade with prazosin (1 mg kg(-1)M(b)) and again after additional blockade of angiotensin converting enzyme (ACE) with enalapril (1 mg kg(-1)M(b)). In untreated fish, exercise was associated with a rapid (within approx. 1-2 min) and sustained increase in Q and P(ven) associated with a significant increase in MCFP (0.17+/-0.02 kPa at rest to 0.27+/-0.02 kPa at the end of exercise). Prazosin treatment did not block the exercise-mediated increase in MCFP (0.25+/-0.04 kPa to 0.33+/-0.04 kPa at the end of exercise), but delayed the other cardiovascular responses to swimming such that Q and P(ven) did not increase significantly until around 10-13 min of exercise, suggesting that an endogenous humoral control mechanism had been activated. Subsequent enalapril treatment revealed that these delayed responses were in fact due to activation of the RAS, because resting P(da) and R(sys) were decreased further and essentially all cardiovascular changes during exercise were abolished. This study shows that the alpha-adrenergic system normally plays an important role in the control of venous function during exercise in rainbow trout. It is also the first study to suggest that the RAS may be an important modulator of venous pressure and capacitance in fish.  相似文献   
4.
While locking plate fixation is becoming increasingly popular for complex and osteoporotic fractures, for many indications compression plating remains the standard choice. This study compares the mechanical behaviour of the more recent locking compression plate (LCP) device, with the traditional dynamic compression plates (DCPs) in bone of varying quality using finite element modelling. The bone properties considered include orthotropy, inhomogeneity, cortical thinning and periosteal apposition associated with osteoporosis. The effect of preloads induced by compression plating was included in the models. Two different fracture scenarios were modelled: one with complete reduction and one with a fracture gap. The results show that the preload arising in DCPs results in large principal strains in the bone all around the perimeter of the screw hole, whereas for LCPs large principal strains occur primarily on the side of the screw proximal to the load. The strains within the bone produced by the two screw types are similar in healthy bone with a reduced fracture gap; however, the DCP produces much larger strains in osteoporotic bone. In the presence of a fracture gap, the DCP results in a considerably larger region with high tensile strains and a slightly smaller region with high compressive strains. These findings provide a biomechanical basis for the reported improved performance of locking plates in poorer bone quality.  相似文献   
5.
6.
In a finite element (FE) analysis of the lumbar spine, different preload application methods that are used in biomechanical studies may yield diverging results. To investigate how the biomechanical behaviour of a spinal implant is affected by the method of applying the preload, hybrid-controlled FE analysis was used to evaluate the biomechanical behaviour of the lumbar spine under different preload application methods. The FE models of anterior lumbar interbody fusion (ALIF) and artificial disc replacement (ADR) were tested under three different loading conditions: a 150 N pressure preload (PP) and 150 and 400 N follower loads (FLs). This study analysed the resulting range of motion (ROM), facet contact force (FCF), inlay contact pressure (ICP) and stress distribution of adjacent discs. The FE results indicated that the ROM of both surgical constructs was related to the preload application method and magnitude; differences in the ROM were within 7% for the ALIF model and 32% for the ADR model. Following the application of the FL and after increasing the FL magnitude, the FCF of the ADR model gradually increased, reaching 45% at the implanted level in torsion. The maximum ICP gradually decreased by 34.1% in torsion and 28.4% in lateral bending. This study concluded that the preload magnitude and application method affect the biomechanical behaviour of the lumbar spine. For the ADR, remarkable alteration was observed while increasing the FL magnitude, particularly in the ROM, FCF and ICP. However, for the ALIF, PP and FL methods had no remarkable alteration in terms of ROM and adjacent disc stress.  相似文献   
7.
介绍一种简单、新型的主要用于蛙心灌注实验的计滴装置   总被引:9,自引:1,他引:8  
目的:介绍一种简单、新型的计滴装置的制作和使用方法.方法:对蛙心灌流中过去曾使用过的ハ-ム法和斯氏法进行了改进.取一个20 ml注射器,其内固定两个电极,用塑料管加工成出、入液管和阻力管.结果:使用新型的计滴装置,可在离体蛙心观察前负荷、后负荷、激素和电解质对心功能的影响.结论:经改进的计滴装置,制作经济,操作简单,和微机配合使用,更具直观性、准确性,能客观地反映各种理化因素对心功能的影响.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号