首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   159篇
  免费   36篇
  国内免费   2篇
  2023年   6篇
  2022年   10篇
  2021年   7篇
  2020年   9篇
  2019年   9篇
  2018年   6篇
  2017年   5篇
  2016年   11篇
  2015年   17篇
  2014年   11篇
  2013年   22篇
  2012年   13篇
  2011年   11篇
  2010年   9篇
  2009年   10篇
  2008年   3篇
  2007年   4篇
  2006年   2篇
  2005年   2篇
  2004年   8篇
  2003年   1篇
  2002年   2篇
  2001年   3篇
  2000年   1篇
  1999年   3篇
  1998年   2篇
  1997年   1篇
  1996年   2篇
  1995年   1篇
  1994年   1篇
  1993年   2篇
  1992年   1篇
  1991年   1篇
  1986年   1篇
排序方式: 共有197条查询结果,搜索用时 171 毫秒
1.
Abstract. A technique for fine-scale vegetation mapping with the aid of low-altitude aerial photography was developed. The procedure is as follows: 1. The site is divided into a lattice pattern - in case the site is too large to fit into a single photograph with satisfactory resolution. The coordinates of every lattice point are surveyed to be used as control points for geometric correction. A photograph of each block of the lattice is taken using a remote-controlled camera system lifted by a captive helium balloon. 2. The vegetation is classified on the basis of a phytosociological survey. 3. The shapes and locations of vegetation patches appearing in the photographs are entered into a computer, using a digitizer. A geometric correction is carried out through coordinate transformation referring to the coordinates of the control points and subsequently a draft vegetation map is produced. Finally, discrepancies are corrected and the map is coloured to produce the final version of the vegetation map. This technique was applied to vegetation mapping at a bar, 500 m wide and 2 km long, in the river Yoshino in Shikoku, Japan. A fine-scale vegetation map was obtained and used to analyse the influence of plants on geomorphic processes and community-specific hydrogeomorphic conditions on the bar.  相似文献   
2.
Calli were induced from 300,000 embryos isolated from immature to mature stage of seeds collected on late September from 14 elite trees. When the embryos were cultured onto plastic Petri-dish containing 20 mL of modified B5 basal medium supplemented with 3% (w/v) sucrose, 500 mg/L casein hydrolysate, 250 mg/L myo-inositol, 0.5% (w/v) polyvinyl polypyrrolidon (PVPP), 2×MS vitamins, 0.5 mg/L gibberellic acid, and 10 mg/L 2,4-D after 2 weeks of culture, yellowish-white calli were immediately formed on the surfaces of embryos, and subcultured for 4 weeks in same culture medium. Because most of calli maintained for more than 3 months were revealed differences in their colors, surface texture, and growth rate, visual selection was made for first round screening. When the size of visually selected calli larger than 19 mm in their diameter were inoculated, persistent proliferation was observed. Among the plating methods tested for the selection of rapid growing cell lines at single cell and/or small cell aggregate level, 2-layer spread plating revealed as the best for single cell cloning. To enhance cell growth and maintain high rate of viability for long-term culture of yew cells in bioreactor, final cell volume less than 50% in SCV seemed to be the best. Time course study revealed that 30% of inoculum density was suitable for fed batch culture. Among the tested conditional media, the rate of 1∶2 (old medium: fresh medium) was recorded at the best for cell growth.  相似文献   
3.
4.
目的:探究小肠CT及双气囊小肠镜诊断克罗恩病患者的差异性。方法:选择2017年4月至2019年3月于我院接受治疗的60例克罗恩病患者,分别实施小肠CT及双气囊小肠镜检测,对比两种检测方式对克罗恩病患者诊断准确率及病变范围、病变位置、活动度和并发症的检测差异。结果:CT检出克罗恩病的准确率96.67%,双气囊小肠镜检出克罗恩病的准确率为93.33%,其差异无统计学意义(P>0.05)。小肠CT主要表现为肠腔狭窄50例(83.33%),肠壁增厚52例(86.67%),肠外淋巴结46例(76.67%),肠系膜水肿及血管改变21例(35.00%),肠外炎症10例(16.67%),瘘管3例(5.00%),瘘道1例(1.67%);双气囊小肠镜表现为环形溃疡、不规则溃疡、环状溃疡等共计46例(76.67%),阿弗他溃疡22例(36.67%),黏膜充血、水肿等26例(43.33%),结节样增生6例(10.00%),小肠肠腔节段性狭窄16例(26.67%),假性息肉9例(15.00%);经病理学检测表现为淋巴细胞、中性粒细胞、嗜酸性粒细胞等炎性浸润,淋巴组织及肉芽组织出现增生小肠CT发现肠外炎症、瘘道、瘘管等合计14例,而双气囊小肠镜未发现并发症。结论:相比于双气囊小肠镜,小肠CT能够更为准确的判断克罗恩病患者是否处于炎症状态,也能够更有效的发现肠外并发症的存在,但小肠CT及双气囊小肠镜联合应用监测效果更佳。  相似文献   
5.
Exposing Pseudomonas aeruginosa biofilm grown on the inner surface of Teflon and silicone tubes to UVC light (265 nm) from light emitting diodes (LED) has previously been shown to substantially reduce biofilm growth. Smaller UVC fluencies were required to disinfect Teflon tubes compared to silicone tubes. Light propagation enhancement in tubes can be obtained if the refractive index of the intra-luminal saline solution is higher than that of the polymer. This condition is achieved by using Teflon tubes with a low refractive index (1.34) instead of the polymers with a high refractive index (1.40–1.50) normally used for tubing in catheter production. Determining whether or not UVC light exposure can disinfect and maintain the intra-luminal number of colony forming units (CFUs) at an exceedingly low level and thus avoid the growth and establishment of biofilm is of interest. The use of UVC diodes is demonstrated to be a preventative disinfection treatment on tubes made of Teflon, which enhances the UVC light propagation, and on tubes made of a softer material, ethylene vinyl acetate (EVA), which is suitable for catheters but much less suitable for UVC light propagation. Simulating an aseptic breach (~103–104 CFU ml?1), the UVC disinfection set-up was demonstrated using tubes contaminated with planktonic P. aeruginosa. After the tubes (10–20 cm) were inoculated with the bacterial solution for 3 h, they were emptied and filled with saline solutions (0.9–20%). Next UVC fluencies (0–21 mJ cm?2) were applied to the tubes 3 h after inoculation. Colony counts were carried out on liquid samples drawn from the tubes the first day after UVC treatment and liquid and surface samples were collected and analyzed 3–4 days later. A fluence of approximately 1.0 mJ cm?2 was noted as being sufficient for no growth for a period of 3–4 days for the Teflon tubes. Determining the fluence threshold for the EVA tubes was not possible. Almost all of the UVC-treated EVA tubes were disinfected simply by filling the tubes with a saline solution. Direct UVC treatment of the contaminated EVA tubes revealed, however, that a fluence of 21 mJ cm?2 killed the bacteria present in the tubes and kept them disinfected for a period of 3–4 days.  相似文献   
6.
Biofilms are commonly associated with an increased risk of patient infection. In peritoneal dialysis (PD), catheter associated infection, especially peritonitis, remains a clinically relevant problem. Although the presence of a biofilm is recognized in relapsing, repeat, and catheter-related peritonitis, it remains poorly characterized. In this review, an update on the role of biofilms in PD infections is presented. The emerging concept that host cells and tissue associated biofilms, in addition to the biofilms on the catheters themselves, contribute to the recalcitrance of infections is discussed. Furthermore, the evidence of biofilms on PD catheters, their developmental stages, and the possible influence of the PD environment are reviewed. The focus is given to ex vivo and in vitro studies that contribute to the elucidation of the interplay between host, microbial, and dialysis factors. The key issues that are still to be answered and the challenges to clinical practice are discussed.  相似文献   
7.
We report the development of an intravascular magnetomotive optical coherence tomography (IV‐MM‐OCT) system used with targeted protein microspheres to detect early‐stage atherosclerotic fatty streaks/plaques. Magnetic microspheres (MSs) were injected in vivo in rabbits, and after 30 minutes of in vivo circulation, excised ex vivo rabbit aorta samples specimens were then imaged ex vivo with our prototype IV‐MM‐OCT system. The alternating magnetic field gradient was provided by a unique pair of external custom‐built electromagnetic coils that modulated the targeted magnetic MSs. The results showed a statistically significant MM‐OCT signal from the aorta samples specimens injected with targeted MSs.

Representative magnetomotive signal (green) using targeted and non‐targeted magnetomotive microspheres in atherosclerotic diseased rabbit aortas.  相似文献   

8.
目的:探讨Cook双球囊联合改良B-Lynch缝合术对产后出血的治疗效果。方法:选取2015年6月~2018年6月在我院经剖宫产术分娩并发生产后出血的产妇81例进行回顾性分析。根据术中止血方法的不同分为两组,对照组40例采用Cook双球囊进行止血,观察组41例在对照组的基础上应用改良B-Lynch缝合术进行止血。对两组患者的手术相关指标、止血成功率、子宫切除率、术后恢复情况和并发症发生情况进行比较。结果:观察组的术中出血量、术后24 h出血量和输血量显著低于对照组(P0.05),止血时间显著短于对照组(P0.05);观察组患者的止血成功率显著高于对照组(P0.05),子宫切除率和切口恢复时间显著低于对照组(P0.05),两组患者的住院时间和并发症发生率比较无统计学差异(P0.05)。结论:Cook双球囊联合改良B-Lynch缝合术对剖宫产产后出血患者的临床效果显著优于单用Cook双球囊,且安全性较高。  相似文献   
9.
Catheter-associated urinary tract infections (CAUTIs) are the most common kind of nosocomial infection. Recent years have seen a significant increase in numbers of infections caused by yeasts of the genus Candida. The adherence of a microorganism to the host surface is a decisive factor in the success of colonization and the pathogenesis of infection. The objective of this work was to evaluate the adherence of species of the genus Candida to urinary catheters. In vitro adherence to the sections of latex and silicon catheters of Candida albicans and Candida parapsilosis were studied. Adherence was measured by counting the number of adhering viable cells and the results were expressed as Colonies Forming Units per mL. The results demonstrated that the latex catheter facilitated adherence more than the silicon catheter (p < 0.01). The adherence of the C. albicans was significantly greater than C. parapsilosis on latex, but it was similar on silicon.  相似文献   
10.
A catheter surface was modified by coating a cellulose acetate polymer. Adhesion of Pseudomonas aeruginosa ATCC 27853 to the surface was investigated by exposing bacterial cultures to three treatments: polymer impregnated with silver ions (Ag+), polymer surfaces coated with lectins and a combination of Ag+ and a lectin coating. The effective concentration of Ag+ providing protection against bacterial biofilm development was 100g/ml and higher. Lectins alone at 10% also showed inhibition of bacterial attachment. However, the best result was achieved against bacterial adhesion and growth on surfaces using a combination of 100 g Ag+/ml and a lectin coating as a surface treatment. This surface treatment was also effective against both fresh culture and a two-week-old culture containing P. aeruginosa producing exopolymers. Our results suggest that Ag+impregnation combined with a lectin coating warrants further investigation as a potential means of protecting catheters.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号