首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   36篇
  免费   0篇
  2021年   4篇
  2020年   3篇
  2019年   2篇
  2018年   8篇
  2017年   2篇
  2016年   2篇
  2015年   5篇
  2013年   1篇
  2006年   3篇
  2003年   1篇
  1998年   1篇
  1996年   1篇
  1994年   1篇
  1991年   1篇
  1980年   1篇
排序方式: 共有36条查询结果,搜索用时 718 毫秒
1.
Phytotoxicity originating from the anaerobic decomposition of couch grass rhizomes has been studied. Short chain aliphatic (acetic, propionic and butyric) acids appear to be mainly responsible but hexanoic, succinic, phenylacetic, cinnamic, p-coumaric, 4-hydroxyphenylpropionic and 3,4-dihydroxyphenylpropionic acids are also present in the phytotoxic solutions formed during the decomposition.  相似文献   
2.

Aim

To compare and evaluate the performance of two different volumetric modulated arc therapy delivery techniques.

Background

Volumetric modulated arc therapy is a novel technique that has recently been made available for clinical use. Planning and dosimetric comparison study was done for Elekta VMAT and Varian RapidArc for different treatment sites.

Materials and methods

Ten patients were selected for the planning comparison study. This includes 2 head and neck, 2 oesophagus, 1 bladder, 3 cervix and 2 rectum cases. Total dose of 50 Gy was given for all the plans. All plans were done for RapidArc using Eclipse and for Elekta VMAT with Monaco treatment planning system. All plans were generated with 6 MV X-rays for both RapidArc and Elekta VMAT. Plans were evaluated based on the ability to meet the dose volume histogram, dose homogeneity index, radiation conformity index, estimated radiation delivery time, integral dose and monitor units needed to deliver the prescribed dose.

Results

RapidArc plans achieved the best conformity (CI95% = 1.08 ± 0.07) while Elekta VMAT plans were slightly inferior (CI95% = 1.10 ± 0.05). The in-homogeneity in the PTV was highest with Elekta VMAT with HI equal to 0.12 ± 0.02 Gy when compared to RapidArc with 0.08 ± 0.03. Significant changes were observed between the RapidArc and Elekta VMAT plans in terms of the healthy tissue mean dose and integral dose. Elekta VMAT plans show a reduction in the healthy tissue mean dose (6.92 ± 2.90) Gy when compared to RapidArc (7.83 ± 3.31) Gy. The integral dose is found to be inferior with Elekta VMAT (11.50 ± 6.49) × 104 Gy cm3 when compared to RapidArc (13.11 ± 7.52) × 104 Gy cm3. Both Varian RapidArc and Elekta VMAT respected the planning objective for all organs at risk. Gamma analysis result for the pre-treatment quality assurance shows good agreement between the planned and delivered fluence for 3 mm DTA, 3% DD for all the evaluated points inside the PTV, for both VMAT and RapidArc techniques.

Conclusion

The study concludes that a variable gantry speed with variable dose rate is important for efficient arc therapy delivery. RapidArc presents a slight improvement in the OAR sparing with better target coverage when compared to Elekta VMAT. Trivial differences were noted in all the plans for organ at risk but the two techniques provided satisfactory conformal avoidance and conformation.  相似文献   
3.
Radiation therapy for patients with non‐small‐cell lung cancer is hampered by acute radiation‐induced toxicity in the esophagus. This study aims to validate that optical coherence tomography (OCT), a minimally invasive imaging technique with high resolution (~10 μm), is able to visualize and monitor acute radiation‐induced esophageal damage (ARIED) in mice. We compare our findings with histopathology as the gold standard. Irradiated mice receive a single dose of 40 Gy at proximal and distal spots of the esophagus of 10.0 mm in diameter. We scan mice using OCT at two, three, and seven days post‐irradiation. In OCT analysis, we define ARIED as a presence of distorted esophageal layering, change in backscattering signal properties, or change in the esophageal wall thickness. The average esophageal wall thickness is 0.53 mm larger on OCT when ARIED is present based on histopathology. The overall sensitivity and specificity of OCT to detect ARIED compared to histopathology are 94% and 47%, respectively. However, the overall sensitivity of OCT to assess ARIED is 100% seven days post‐irradiation. We validate the capability of OCT to detect ARIED induced by high doses in mice. Nevertheless, clinical studies are required to assess the potential role of OCT to visualize ARIED in humans.   相似文献   
4.
The effects of irrigation and fertiliser regimes on N leaching from the production of couch grass (Cynodon dactylon L.) sod, on a free-draining sandy soil, were evaluated in a 22-month field study. The experimental design used a randomised-block, split-plot design with three replicates. Main plots consisted of two irrigation treatments: 70 and 140% daily replacement of pan evaporation; four subplot fertiliser types (water-soluble (predominately NH4NO3), control-release, pelletised poultry manure and pelletised biosolids); and three N application rates (100, 200 and 300 kg N ha−1 per crop). Nitrogen leaching was assessed by measuring the leachate volumes and concentrations of N species leached from soil lysimeters (250 mm in diameter by 950 mm in length) installed in 10 m2 turfgrass plots. Nitrogen leaching ranged from 33 to 167 kg N ha−1 over 22 months, depending upon the irrigation and fertiliser treatment. Irrigation treatment affected N leaching more than fertiliser treatment, and increasing the irrigation from 70 to 140% replacement of daily pan evaporation increased N leaching for all fertiliser types, and by up to four times. Forty six to 76% of losses occurred from the high irrigation treatments during the first 16 weeks after the turfgrass was planted as rhizomes. By contrast, N leaching did not appear to increase following harvest of sod. At the high irrigation treatment, N leaching was greater for the pelletised biosolids than the control-release; while at the low irrigation treatment, N leaching did not vary between fertiliser types. A significant proportion of the N leached was in the organic form. Therefore, we recommend total N and mineral N be measured when assessing N leaching from turfgrass. Nitrogen leaching from turfgrass production is low from all fertiliser types when the irrigation matches turfgrass water use and N is applied at a rate and frequency that approximates turfgrass requirements. Section Editor: P. J. Randall  相似文献   
5.

Purpose

The purpose of this study was to verify whether the dynamic tumor tracking (DTT) feature of a Vero4DRT system performs with 10-mm-long and 0.28 mm diameter gold anchor markers.

Methods

Gold anchor markers with a length of 10 mm and a diameter of 0.28 mm were used. Gold anchor markers were injected with short and long types into bolus material. These markers were sandwiched by a Tough Water (TW) phantom in the bolus material. For the investigation of 4-dimensional (4D) modeling feasibility under various phantom thicknesses, the TW phantom was added at 2 cm intervals (in upper and lower each by 1 cm). A programmable respiratory motion table was used to simulate breathing-induced organ motion, with an amplitude of 30 mm and a breathing cycle of 3 s. X-ray imaging parameters of 80 kV and 125 kV (320 mA and 5 ms) were used. The least detection error of the fiducial marker was defined as the 4D-modeling limitation.

Results

The 4D modeling process was attempted using short and long marker types and its limitation with the short and long types was with phantom thicknesses of 6 and 10 cm at 80 kV and 125 kV, respectively. However, the loss in detectability of the gold anchor because of 4D-modeling errors was found to be approximately 6% (2/31) with a phantom thickness of 2 cm under 125 kV. 4D-modeling could be performed except under the described conditions.

Conclusions

This work showed that a 10-mm-long gold anchor marker in short and long types can be used with DTT for short water equivalent path length site, such as lung cancer patients, in the Vero4DRT system.  相似文献   
6.

Aim

In this study, at different fields, energies and gantry angles, treatment couch and rails dose absorption ratio and treatment couch effect on surface and build-up region doses were examined.

Background

It is assumed that radiation attenuation is minimal because the carbon fiber couches have low density and it is not generally accounted for during treatment planning. Consequently, it leads to a major dosimetric mistake.

Materials and methods

Solid water phantom was used for relative dose measurement. The measurements were done using a Farmer ion chamber with 0.6 cc volume and a parallel plane ion chamber starting from surface with 1 mm depth intervals at 10 × 10 cm2 field, SSD 100 cm. Measurements were taken for situations where the beams intersect the couch and couch rails.

Results

Dose absorption ratio of carbon fiber couch obtained at gantry angle of 180° was 1.52%, 0.69%, 0.33% and 0.25% at different field sizes for 6 MV. For 15 MV, this ratio was 0.95%, 0.27%, 0.20% and 0.05%. The absorption ratio is between 3.4% and 1.22% when the beams intersect with couch rails. The couch effect increased surface dose from 14% to 70% for 6 MV and from 11.34% to 53.03% for 15 MV.

Conclusions

The results showed that the carbon fiber couch increased surface dose during posterior irradiation. Therefore, the skin-sparing effect of the high energy beams was decreased. If the effect of couch is not considered, it may cause significant differences at dose which reaches the patient and may cause tissue problems such as erythema.  相似文献   
7.
A robotic couch capable of six degrees of freedom (6-DoF) of motion was introduced for state-of-the-art radiation therapy. Patient treatment requires precise quality assurance (QA) of 6-DoF. Unfortunately, conventional methods do not provide the requisite accuracy and precision. Therefore, we developed a high-precision automated QA system using a visual tracking system (VTS). The VTS comprises four motion-sensing cameras, a cube with infrared reflective markers. To acquire data in treatment room coordinates, a transformation matrix from VTS coordinates to treatment room coordinates was determined.The mean error and standard deviation of linear and rotational motions, as well as couch sagging were analyzed from continuously acquired images in the moving couch. The accuracy of VTS was 0.024 mm deviation for the sinusoidal motion, and the accuracy of the transformation matrix was 0.02 mm. In a cross-comparison, the difference between Laser Tracker (FARO) measurements was 0.14 ± 0.12 mm for translation and 0.032 ± 0.026° on average for yaw rotation. The new system provides QA of yaw, pitch and roll motion as well as sagging of the couch and sub-millimeter/degree accuracy together with precision.  相似文献   
8.
PurposeTo present our methods and results regarding the modeling of a carbon fiber couch (Varian Exact IGRT) in the RayStation treatment planning system (TPS).MethodsThree geometrical-models (GMs) were implemented in the TPS to represent the three different regions of the couch (thick, medium and thin). The materials and densities of each GM component were tuned to maximize the agreement between measured and calculated attenuations. Moreover, a couch computed-tomography (CT) scan was acquired and dosimetrically compared with the GMs. For validation, plan-specific quality assurance (QA) of VMAT plans (TG-119 cases, 5 prostate and 5 H&N clinical cases) was performed by comparing measured dose distributions with doses computed with and without including the GMs in the TPS.ResultsCouch attenuations up to 4.3% were measured (energy: 6MV). Compared to couch CT, GMs could be modified to optimize the agreement with measurements and reduce dependence on the dose grid resolution. For both couch CT and GM, absolute deviations between measured and calculated attenuations were within 1.0%. When including the GMs in plan-specific QA, global 2%/2 mm γ-pass rates showed an average improvement of 4.8% (p-value < 0.001, max +18.6%). The couch reduced the mean dose to targets by up to 2.4% of the prescribed dose for prostate cases and up to 1.4% for H&N cases.ConclusionsRayStation accurately considers the implemented couch GMs replicating measured attenuations within an uncertainty of 1.0%. Materials and densities are proposed for the Varian Exact IGRT couch. The results obtained justify introducing couch GMs in clinical routine.  相似文献   
9.
BackgroundThe target volume increases when the prostate and pelvic lymph nodes (PLNs) are combined, and the fiducial markers (FMs) are placed at the edge of the irradiation field. Thus, the position of FMs may be changed by the rotational errors (REs) of “whole pelvis”. The aim of this study was to examine the impact of REs of “whole pelvis” on the dose of FMs-based image-guided radiotherapy to the PLNs and the small bowel in prostate cancer including the PLNs.Materials and methodsWe retrospectively evaluated 10 patients who underwent prostate cancer radiotherapy involving the PLNs. The position of FMs was calculated from the radiographs obtained before and after the 6D correction of pelvic REs. We simulated the delivery dose considering the daily pelvic REs and calculated the difference from the planned dose in the D98% of the PLN clinical target volume and the D2cc, and V45Gy of the small bowel.ResultThe position of FMs strongly correlated with the pelvic REs in the pitch direction (r = 0.7788). However, the mean delivered doses to PLNs for 10 patients were not significantly different from the planned doses (p = 0.625). Although the D2cc and V45Gy of the small bowel strongly correlated with the pitch rotation of the pelvis, there was no significant difference between the delivered and planned doses (p = 0.922 and p = 0.232, respectively).ConclusionThe dosimetric effect of pelvic REs on the dose to PLNs and the small bowel was negligible during the treatment course.  相似文献   
10.
Deep inspiration breath hold (DIBH) is an effective technique to reduce cardiac and pulmonary dose during breast radiotherapy (RT). However, as a result of expense and the technical challenges of program implementation, DIBH has not been widely adopted in clinical practice.This report describes a program for DIBH this is relatively inexpensive to implement and has little impact on patient throughput. Multiple redundant mechanisms are incorporated to assure accurate and safe delivery of RT during DIBH. Laser alignment verifies that chest wall excursion is reliably reproduced and maintained during treatment. Chest wall excursion is also monitored independently using an infrared camera trained on a reflective marker on the chest wall. This system automatically triggers “beam off” in the event of movement of the target beyond pre-determined thresholds. Finally, physician review of cine imaging obtained during treatment provides an off-line verification of accurate RT delivery. The approach described herein lowers the investment necessary for implementation of DIBH and may facilitate broader adoption of this valuable technique.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号