1.
TAVI devices are manufactured with cylindrical frames. However, the frames are rarely cylindrical post-deployment since deformation due to localised under expansion can be induced by calcified material on the native valve leaflets exerting irregular forces upon the frame. Consequently, the leaflets within a deformed TAVI device may undergo elevated stress during operation, which may lead to premature device failure.Using computational analysis a complete TAVI device model was simulated undergoing deployment into an aortic root model derived from CT data for a patient with severe calcific aortic stenosis, followed by a pressure simulated cardiac cycle. The complete analysis was performed eight times, each with the device at a different rotational orientation relative to the native valve, with an increment spacing of 15°.The TAVI device frames consistently featured significant distortions associated with bulky calcified material at the base of the non-coronary sinus. It was found that the average von Mises stress in the prosthetic valves was only increased in one of the cases relative to an idealised device. However, the maximum von Mises stress in the prosthetic valves was elevated in the majority of the cases.Furthermore, it was found that there were preferable orientations to deploy the prosthetic device, in this case, when the prosthetic leaflets were aligned with the native leaflets. As device orientation deviated from this orientation, the stresses in the valve increased because the distance between the prosthetic commissures decreased. This potentially could represent a sufficient increase in stress to induce variation in device lifespan.  相似文献   
2.
Transcatheter aortic valve replacement (TAVR) is a new technology that recently has been shown to improve survival and quality of life in patients with severe symptomatic aortic stenosis who are not surgical candidates. The development and design of transcatheter valves has been ongoing for the past 20 years, and TAVR has now been approved by the FDA as a treatment for aortic stenosis in patients who are not surgical candidates. In the United States, there are currently two transcatheter valves available: the Edwards Sapien Valve and the Medtronic CoreValve. While similar in some design elements, they also have characteristic differences that affect both the mechanism of delivery as well as performance in patients. This review aims to take a closer look at the development of this new technology, review the published clinical results, and look toward the future of transcatheter valve therapeutics and the challenges therein.  相似文献   
3.
Transcatheter aortic valve implantation (TAVI) is a minimally invasive procedure introduced to treat aortic valve stenosis in elder patients. Its clinical outcomes are strictly related to patient selection, operator skills, and dedicated pre-procedural planning based on accurate medical imaging analysis. The goal of this work is to define a finite element framework to realistically reproduce TAVI and evaluate the impact of aortic root anatomy on procedure outcomes starting from two real patient datasets. Patient-specific aortic root models including native leaflets, calcific plaques extracted from medical images, and an accurate stent geometry based on micro-tomography reconstruction are key aspects included in the present study. Through the proposed simulation strategy we observe that, in both patients, stent apposition significantly induces anatomical configuration changes, while it leads to different stress distributions on the aortic wall. Moreover, for one patient, a possible risk of paravalvular leakage has been found while an asymmetric coaptation occurs in both investigated cases. Post-operative clinical data, that have been analyzed to prove reliability of the performed simulations, show a good agreement with analysis results. The proposed work thus represents a further step towards the use of realistic computer-based simulations of TAVI procedures, aiming at improving the efficacy of the operation technique and supporting device optimization.  相似文献   
4.

Background

Although CT-studies as well as intraoperative analyses have described broad anatomic variations of the aortic annulus, which is predominantly found non-circular, commercially available transcatheter aortic heart valve prostheses are circular. In this study, we hypothesize that the in vitro hydrodynamic function of a self-expanding transcatheter heart valve (Medtronic CoreValve®) assessed in an oval compartment representing the aortic annulus will differ from the conventionally used circular compartment.

Methods

Medtronic CoreValve® prostheses were tested in specifically designed and fabricated silicone compartments with three degrees of defined ovalities. The measurements were performed in a left heart simulator at three different flow rates. In this setting, regurgitation flow, effective orifice area, and systolic pressure gradient across the valve were determined. In addition, high speed video recordings were taken to investigate leaflet kinematics.

Results

The pressure difference across the prosthesis increased with rising ovality. The effective orifice areas were only slightly impacted. The analyses of the regurgitation showed minor changes and partially lower regurgitation when switching from round to slightly oval settings, followed by strong increases for further ovalization. The high speed videos show minor central leakage and impaired leaflet apposition for strong ovalities, but no leaflet/stentframe contact in any setting.

Conclusion

This study quantifies the influence of oval expansion of transcatheter heart valve prostheses on their hydrodynamic performance. While slight ovalities were well tolerated by a self-expanding prosthesis, more significant ovality led to worsening of prosthesis function and regurgitation.  相似文献   
5.
在老年人群中,由于主动脉瓣膜退行性病变或钙化导致的主动脉狭窄已成为最常见的原发性瓣膜病,尽管传统的开放式主动脉人工瓣膜置换术疗效显著,但其对患者一般情况要求较高,适应证较窄。经皮主动脉瓣置入术的出现改变这一状况。目前,这类手术有效改善了患者的生存质量和期望。  相似文献   
6.
The analysis is based on a finite element procedure to extract the contact forces between an implanted Nitinol stent and the surrounding host tissue using postoperative CT images. The methodology was applied for patients (N=46) which have undergone a TAVI procedure with the Medtronic CoreValve Revalving System (MCRS) to obtain corresponding deformation and force maps. The postoperative CT data were recorded for each patient in both systolic and diastolic phase of the heart cycle. Scalar parameters were defined, which map deformed geometry and contact force field to mechanically relevant quantities: radial dilatation, radial shape distortion, non-convex points, mean force, a force deviation measure and a pressure equivalent. The latter demonstrates that in the area of the aortic root, the added circumferential loading is of the same order as the baseline average blood pressure, thus leading to a doubling of the local mechanical load. Generally the force distribution along the stent is non-homogeneous. A comparison of systolic and diastolic data revealed slightly higher contact forces during the diastole, indicating that the stent has to carry more load in this phase. The geometrical and mechanical parameters were compared for two types of clinical complication: para-valvular leakage (PVL) and permanent pacemaker requirement (PPM). It was found that an increase in mean force can be associated with both complications; significantly for PVL and as a trend for PPM.  相似文献   
7.
Abstract

Background: In this study we sought to examine whether transcatheter aortic valve implantation (TAVI) is followed by a change in the plasma levels of novel cardiovascular biomarkers.

Methods: We collected blood samples of 79 patients with severe aortic valve stenosis undergoing TAVI before and at 7 days, 1 month, 3 months and 6 months post TAVI and analyzed the plasma concentrations of GDF-15, H-FABP, fetuin-A, galectin 3, sST2 and suPAR by means of ELISA.

Results: There was a significant increase in the concentration of fetuin-A (median: 52.44 mg/ml to 113.2 mg/ml, p?<?0.001) and a significant decrease of H–FABP after TAVI (median: 4.835 ng/ml to 2.534 ng/ml, p?<?0.001). The concentrations of suPAR and sST2 showed an initial increase (suPAR median: 2755 pg/ml 3489 pg/ml, p?<?0.001; sST2 median: 5832 pg/ml to 7137 pq/ml, p?<?0.001) and subsequently decreased significantly.

Conclusion: We hypothesize that the decrease of H-FABP and the increase of fetuin-A could be due to a hemodynamic improvement after valve replacement. The initial increase of suPAR could indicate an inflammatory stimulus and the significant increase in sST2 could be due to the mechanical strain caused by implantation of the valve.  相似文献   
8.

Aims

Since the introduction of transcatheter aortic valve implantation (TAVI), newer generation and novel devices such as the retrievable JenaValve™ have been developed. We evaluated the procedural and 6-month results of our first experience with implantation of the JenaValve™.

Methods and results

From June 2012 to December 2013, 24 consecutive patients (mean age 80 ± 7 years, 42 % male) underwent an elective transapical TAVI with the JenaValve™. Device success was 88 %. The mortality rate was 4 % at 30 days and 31 % at 6 months. TAVI reduced the mean transvalvular gradient (44.2 ± 11.1 mmHg vs. 12.3 ± 4.3 mmHg, p < 0.001) and increased the mean aortic valve area (0.8 3 ± 0.23 to 1.70 ± 0.44 cm2). A mild paravalvular leakage (PVL) occurred in 4 patients (18 %) and a moderate PVL in 1 patient (4 %). Mean New York Heart Association Functional Class improved from 2.9 ± 0.5 to 2.0 ± 0.8 at 30 days.

Conclusion

TAVI using the JenaValve™ prosthesis seems adequate and safe in this first experience cohort.  相似文献   
9.
Malvindi  P. G.  Luthra  S.  Sarvananthan  S.  Zingale  A.  Olevano  C.  Ohri  S. 《Netherlands heart journal》2021,29(2):71-77
Netherlands Heart Journal - There is growing interest in infections occurring after transcatheter aortic valve implantation (TAVI). The incidence, and clinical and anatomical features suggest many...  相似文献   
10.

Purpose

To assess current antithrombotic treatment strategies in the Netherlands in patients undergoing transcatheter aortic valve implantation (TAVI).

Methods

For every Dutch hospital performing TAVI (n = 14) an interventional cardiologist experienced in performing TAVI was interviewed concerning heparin, aspirin, thienopyridine and oral anticoagulation treatment in patients undergoing TAVI.

Results

The response rate was 100 %. In every centre, a protocol for antithrombotic treatment after TAVI was available. Aspirin was prescribed in all centres, concomitant clopidogrel was prescribed 13 of the 14 centres. Duration of concomitant clopidogrel was 3 months in over two-thirds of cases. In 2 centres, duration of concomitant clopidogrel was based upon type of prosthesis: 6 months versus 3 months for supra-annular and intra-annular prostheses, respectively.

Conclusions

Leaning on a small basis of evidence and recommendations, the antithrombotic policy for patients undergoing TAVI is highly variable in the Netherlands. As a standardised regimen might further reduce haemorrhagic complications, large randomised clinical trials may help to establish the most appropriate approach.

Electronic supplementary material

The online version of this article (doi:10.1007/s12471-013-0496-6) contains supplementary material, which is available to authorized users.  相似文献   