1.
Kazuki Kubo Hajime Monzen Kohei Shimomura Kenji Matsumoto Tomoharu Sato Mikoto Tamura Kiyoshi Nakamatsu Kentaro Ishii Ryu Kawamorita 《Reports of Practical Oncology and Radiotherapy》2019,24(6):600-605
AimTo evaluate the success of a patient-specific intensity modulated radiation therapy (IMRT) quality assurance (QA) practice for prostate cancer patients across multiple institutions using a questionnaire survey.BackgroundThe IMRT QA practice involves different methods of dose distribution verification and analysis at different institutions.Materials and MethodsTwo full-arc volumetric modulated arc therapy (VMAT) plan and 7 fixed-gantry IMRT plan with DMLC were used for patient specific QA across 22 institutions. The same computed tomography image and structure set were used for all plans. Each institution recalculated the dose distribution with fixed monitor units and without any modification. Single-point dose measurement with a cylindrical ionization chamber and dose distribution verification with a multi-detector or radiochromic film were performed, according to the QA process at each institution.ResultsTwenty-two institutions performed the patient-specific IMRT QA verifications. With a single-point dose measurement at the isocenter, the average difference between the calculated and measured doses was 0.5 ± 1.9%. For the comparison of dose distributions, 18 institutions used a two or three-dimensional array detector, while the others used Gafchromic film. In the γ test with dose difference/distance-to-agreement criteria of 3%?3 mm and 2%?2 mm with a 30% dose threshold, the median gamma pass rates were 99.3% (range: 41.7%–100.0%) and 96.4% (range: 29.4%–100.0%), respectively.ConclusionThis survey was an informative trial to understand the verification status of patient-specific IMRT QA measurements for prostate cancer. In most institutions, the point dose measurement and dose distribution differences met the desired criteria. 相似文献
2.
3.
Shoki Inui Yoshihiro Ueda Shunsuke Ono Shingo Ohira Masaru Isono Yuya Nitta Hikari Ueda Masayoshi Miyazaki Masahiko Koizumi Teruki Teshima 《Reports of Practical Oncology and Radiotherapy》2021,26(2):281
BackgroundThe aim of the study was to evaluate analysis criteria for the identification of the presence of rectal gas during volumetric modulated arc therapy (VMAT) for prostate cancer patients by using electronic portal imaging device (EPID)-based in vivo dosimetry (IVD).Materials and methodsAll measurements were performed by determining the cumulative EPID images in an integrated acquisition mode and analyzed using PerFRACTION commercial software. Systematic setup errors were simulated by moving the anthropomorphic phantom in each translational and rotational direction. The inhomogeneity regions were also simulated by the I’mRT phantom attached to the Quasar phantom. The presence of small and large air cavities (12 and 48 cm3) was controlled by moving the Quasar phantom in several timings during VMAT. Sixteen prostate cancer patients received EPID-based IVD during VMAT.ResultsIn the phantom study, no systematic setup error was detected in the range that can happen in clinical (< 5-mm and < 3 degree). The pass rate of 2% dose difference (DD2%) in small and large air cavities was 98.74% and 79.05%, respectively, in the appearance of the air cavity after irradiation three quarter times. In the clinical study, some fractions caused a sharp decline in the DD2% pass rate. The proportion for DD2% < 90% was 13.4% of all fractions. Rectal gas was confirmed in 11.0% of fractions by acquiring kilo-voltage X-ray images after the treatment.ConclusionsOur results suggest that analysis criteria of 2% dose difference in EPID-based IVD was a suitable method for identification of rectal gas during VMAT for prostate cancer patients. 相似文献
4.
Janusz Winiecki Zbigniew ?urawski Barbara Drzewiecka Krzysztof ?losarek 《Reports of Practical Oncology and Radiotherapy》2011,16(1):1-9
Background
During a proper execution of dMLC plans, there occurs an undesired but frequent effect of the dose locally accumulated by tissue being significantly different than expected. The conventional dosimetric QA procedures give only a partial picture of the quality of IMRT treatment, because their solely quantitative outcomes usually correspond more to the total area of the detector than the actually irradiated volume.Aim
The aim of this investigation was to develop a procedure of dynamic plans verification which would be able to visualize the potential anomalies of dose distribution and specify which tissue they exactly refer to.Materials & methods
The paper presents a method discovered and clinically examined in our department. It is based on a Gamma Evaluation concept and allows accurate localization of deviations between predicted and acquired dose distributions, which were registered by portal as well as film dosimetry. All the calculations were performed on the self-made software GammaEval, the γ-images (2-dimensional distribution of γ-values) and γ-histograms were created as quantitative outcomes of verification.Results
Over 150 maps of dose distribution have been analyzed and the cross-examination of the gamma images with DRRs was performed.Conclusions
It seems, that the complex monitoring of treatment would be possible owing to the images obtained as a cross-examination of γ-images and corresponding DRRs. 相似文献5.
Tapan Biswas Olga E. Zolova Felipe Lombó Jose A. Salas Sylvie Garneau-Tsodikova 《Journal of molecular biology》2010,397(2):495-2570
Thiocoraline is a thiodepsipeptide with potent antitumor activity. TioX, a protein with an unidentified function, is encoded by a gene of the thiocoraline biosynthetic gene cluster. The crystal structure of the full-length TioX protein at 2.15 Å resolution reveals that TioX protomer shares an ancient βαβββ fold motif with glyoxalase I and bleomycin resistance protein families, despite a very low sequence homology. Intriguingly, four TioX monomers form a unique 2-fold symmetric tetrameric assembly that is stabilized by four intermolecular disulfide bonds formed cyclically between Cys60 and Cys66 of adjacent monomers. The arrangement of two of the four monomers in the TioX tetramer is analogous to that in dimeric bleomycin resistance proteins. This analogy indicates that this novel higher-order structural scaffold of TioX may have evolved to bind thiocoraline. Our equilibrium titration studies demonstrate the binding of a thiocoraline chromophore analog, quinaldic acid, to TioX, thereby substantiating this model. Furthermore, a strain of Streptomyces albus containing an exogenous thiocoraline gene cluster devoid of functional tioX maintains thiocoraline production, albeit with a lower yield. Taken together, these observations rule out a direct enzymatic function of TioX and suggest that TioX is involved in thiocoraline resistance or secretion. 相似文献
6.
《Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)》2016,32(11):1479-1487
The purpose of this study was to evaluate the suitability of the Daily QA 3 (Sun Nuclear Corporation, Melbourne, USA) device as a safe quality assurance device for control of machine specific parameters, such as linear accelerator output, beam quality and beam flatness and symmetry. Measurements were performed using three Varian 2300iX linear accelerators. The suitability of Daily QA 3 as a device for quality control of linear accelerator parameters was investigated for both 6 and 10 MV photons and 6, 9, 12, 15 and 18 MeV electrons. Measurements of machine specific using the Daily QA 3 device were compared to corresponding measurements using a simpler constancy meter, Farmer chamber and plane parallel ionisation chamber in a water tank. The Daily QA 3 device showed a linear dose response making it a suitable device for detection of output variations during routine measurements. It was noted that over estimations of variations compared with Farmer chamber readings were seen if the Daily QA 3 wasn’t calibrated for output and sensitivity on a regular eight to ten monthly basis. Temperature-pressure correction factors calculated by Daily QA 3 also contributed towards larger short term variations seen in output measurements. Energy, symmetry and flatness variations detected by Daily QA 3 were consistent with measurements performed in water tank using a parallel plate chamber. It was concluded that the Daily QA 3 device is suitable for routine daily and fortnightly quality assurance of linear accelerator beam parameters however a regular eight-ten monthly dose and detector array calibration will improve error detection capabilities of the device. 相似文献
7.
8.
Omid Tavassoly Dorin Sade Santu Bera Shira Shaham-Niv David J. Vocadlo Ehud Gazit 《Journal of molecular biology》2018,430(20):3847-3862
Quinolinic acid (QA), a downstream neurometabolite in the kynurenine pathway, the biosynthetic pathway of tryptophan, is associated with neurodegenerative diseases pathology. Mutations in genes encoding kynurenine pathway enzymes, which control the level of QA production, are linked with elevated risk of developing Parkinson's disease. Recent findings have revealed the accumulation and deposition of QA in post-mortem samples, as well as in cellular models of Alzheimer's disease and related disorders. Furthermore, intrastriatal inoculation of mice with QA results in increased levels of phosphorylated α-synuclein and neurodegenerative pathological and behavioral characteristics. However, the cellular and molecular mechanisms underlying the involvement of QA accumulation in protein aggregation and neurodegeneration remain elusive. We recently established that self-assembled ordered structures are formed by various metabolites and hypothesized that these “metabolite amyloids” may seed amyloidogenic proteins. Here we demonstrate the formation of QA amyloid-like fibrillar assemblies and seeding of α-synuclein aggregation by these nanostructures both in vitro and in cell culture. Notably, α-synuclein aggregation kinetics was accelerated by an order of magnitude. Additional amyloid-like properties of QA assemblies were demonstrated using thioflavin T assay, powder X-ray diffraction and cell apoptosis analysis. Moreover, fluorescently labeled QA assemblies were internalized by neuronal cells and co-localized with α-synuclein aggregates. In addition, we observed cell-to-cell propagation of fluorescently labeled QA assemblies in a co-culture of treated and untreated cells. Our findings suggest that excess QA levels, due to mutations in the kynurenine pathway, for example, may lead to the formation of metabolite assemblies that seed α-synuclein aggregation, resulting in neuronal toxicity and induction of Parkinson's disease. 相似文献
9.
Background
Safe High Dose Rate Brachytherapy (HDR-BT) requires quality assurance/quality control (QA/QC) according to IPEM and ESTRO recommendations. Recent advances in real-time dosimetry and related developments of QA, QC and in vivo dosimetry (IVD) systems have offered new possibilities for effective independent treatment verification, and thus for improving the patient safety.Contributions
This paper briefly reports the state of the art of different QA and QC approaches and systems. It also presents our related studies, carried out within the framework of DoRGaN research project, which have led to two proposed instruments: a QA pretreatment instrumented phantom and a QC gynecological applicator. Both systems implement a real-time dwell-source distance-measuring approach using multiple Gallium Nitride (GaN) dosimetry probes. First prototypes have been designed and tested. Their characteristics (including those of the employed GaN probes) are evaluated in comparison with the state of the art.Conclusion
For developing systems for HDR-BT, the GaN probe has been shown to meet requirements for high sensitivity, high measurement rate, small response anisotropy and large dose measurement range. The proposed QA instrumented phantom has comparable or better characteristics when compared with diode-based and Al2O3:C-based systems. The other QC gynecological applicator has higher time and spatial resolutions than the state-of-the-art IVD systems, which proves that it is suitable for real-time monitoring of HDR-BT physical parameters. 相似文献10.
Umul Kulthum Ahmed N. Claire Maller Asif J. Iqbal Lamyaa Al-Riyami William Harnett John G. Raynes 《The Journal of biological chemistry》2016,291(22):11939-11953
Parasitic nematodes manufacture various carbohydrate-linked phosphorylcholine (PCh)-containing molecules, including ES-62, a protein with an N-linked glycan terminally substituted with PCh. The PCh component is biologically important because it is required for immunomodulatory effects. We showed that most ES-62 was bound to a single protein, C-reactive protein (CRP), in normal human serum, displaying a calcium-dependent, high-avidity interaction and ability to form large complexes. Unexpectedly, CRP binding to ES-62 failed to efficiently activate complement as far as the C3 convertase stage in comparison with PCh-BSA and PCh-containing Streptococcus pneumoniae cell wall polysaccharide. C1q capture assays demonstrated an ES-62-CRP-C1q interaction in serum. The three ligands all activated C1 and generated C4b to similar extents. However, a C2a active site was not generated following ES-62 binding to CRP, demonstrating that C2 cleavage was far less efficient for ES-62-containing complexes. We proposed that failure of C2 cleavage was due to the flexible nature of carbohydrate-bound PCh and that reduced proximity of the C1 complex was the reason that C2 was poorly cleaved. This was confirmed using synthetic analogues that were similar to ES-62 only in respect of having a flexible PCh. Furthermore, ES-62 was shown to deplete early complement components, such as the rate-limiting C4, following CRP interaction and thereby inhibit classical pathway activation. Thus, flexible PCh-glycan represents a novel mechanism for subversion of complement activation. These data illustrate the importance of the rate-limiting C4/C2 stage of complement activation and reveal a new addition to the repertoire of ES-62 immunomodulatory mechanisms with possible therapeutic applications. 相似文献