首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   22篇
  免费   6篇
  2023年   1篇
  2019年   4篇
  2018年   2篇
  2017年   2篇
  2016年   1篇
  2014年   3篇
  2013年   5篇
  2012年   1篇
  2010年   1篇
  2009年   1篇
  2008年   1篇
  2007年   1篇
  2004年   1篇
  2001年   1篇
  1996年   1篇
  1995年   1篇
  1977年   1篇
排序方式: 共有28条查询结果,搜索用时 15 毫秒
1.
An analysis of the anterior patellar groove of the human femur shows considerable variation in its medial and lateral spects. The groove itself, measured by the angle it encloses, shows considerably less variation than its individual components. The suggested functional relationship between bicondylar angle and lateral elevation of the patellar groove does not obtain for this sample.  相似文献   
2.
镍钛聚髌器治疗髌骨骨折的电测分析   总被引:13,自引:0,他引:13  
应用电阻测度应变技术,得到镍钛聚髌器这一记忆合金内固定器的应力-应变关系曲线,较为精确地测定了镍钛聚髌器动态聚合加压髌骨于解剖位的生物力学力值,结果表明:镍钛聚髌器可从9个方向产生向心聚合力,纵向为主,记忆加压力值为13.67Kg,侧向为辅,永加压力值为5.19Kg,并具有一定的耐疲劳性。本实验为临床使用及指导病人术后功能锻炼提供了科学的依据,并为研究动态记忆力学下的骨愈合机理提供了实验基础。  相似文献   
3.
Patellar tendon allografts, retrieved from cadaveric human donors, are widely used for replacement of damaged cruciate ligaments. In common with other tissue allografts originating from cadaveric donors, there are concerns regarding the potential for disease transmission from the donor to the recipient. Additionally, retrieval and subsequent processing protocols expose the graft to the risk of environmental contamination. For these reasons, disinfection or sterilisation protocols are necessary for these grafts before they are used clinically. A high-level disinfection protocol, utilising peracetic acid (PAA), has been developed and investigated for its effects on the biocompatibility and biomechanics of the patellar tendon allografts. PAA disinfection did not render the grafts either cytotoxic or liable to provoke an inflammatory response as assessed in vitro . However, the protocol was shown to increase the size of gaps between the tendon fibres in the matrix and render the grafts more susceptible to digestion with collagenase. Biomechanical studies of the tendons showed that PAA treatment had no effect on the ultimate tensile stress or Young's modulus of the tendons, and that ultimate strain was significantly higher in PAA treated tendons.  相似文献   
4.
Tendon-to-bone healing following acute injury is generally poor and often fails to restore normal tendon biomechanical properties. In recent years, the murine patellar tendon (PT) has become an important model system for studying tendon healing and repair due to its genetic tractability and accessible location within the knee. However, the mechanical properties of native murine PT, specifically the regional differences in tissue strains during loading, and the biomechanical outcomes of natural PT-to-bone healing have not been well characterized. Thus, in this study, we analyzed the global biomechanical properties and regional strain patterns of both normal and naturally healing murine PT at three time points (2, 5, and 8 weeks) following acute surgical rupture of the tibial enthesis. Normal murine PT exhibited distinct regional variations in tissue strain, with the insertion region experiencing approximately 2.5 times greater strain than the midsubstance at failure (10.80±2.52% vs. 4.11±1.40%; mean±SEM). Injured tendons showed reduced structural (ultimate load and linear stiffness) and material (ultimate stress and linear modulus) properties compared to both normal and contralateral sham-operated tendons at all healing time points. Injured tendons also displayed increased local strain in the insertion region compared to contralateral shams at both physiologic and failure load levels. 93.3% of injured tendons failed at the tibial insertion, compared to only 60% and 66.7% of normal and sham tendons, respectively. These results indicate that 8 weeks of natural tendon-to-bone healing does not restore normal biomechanical function to the murine PT following injury.  相似文献   
5.
The knee ligaments and patellar tendon function in concert with each other and other joint tissues, and are adapted to their specific physiological function via geometry and material properties. However, it is not well known how the viscoelastic and quasi-static material properties compare between the ligaments. The purpose of this study was to characterize and compare these material properties between the knee ligaments and patellar tendon.Dumbbell-shaped tensile test samples were cut from bovine knee ligaments (ACL, LCL, MCL, PCL) and patellar tendon (PT) and subjected to tensile testing (n = 10 per ligament type). A sinusoidal loading test was performed at 8% strain with 0.5% strain amplitude using 0.1, 0.5 and 1 Hz frequencies. Subsequently, an ultimate tensile test was performed to investigate the stress-strain characteristics.At 0.1 Hz, the phase difference between stress and strain was higher in LCL compared with ACL, PCL and PT (p < 0.05), and at 0.5 Hz that was higher in LCL compared with all other ligaments and PT (p < 0.05). PT had the longest toe-region strain (p < 0.05 compared with PCL and MCL) and MCL had the highest linear and strain-dependent modulus, and toughness (p < 0.05 compared with ACL, LCL and PT).The results indicate that LCL is more viscous than other ligaments at low-frequency loads. MCL was the stiffest and toughest, and its modulus increased most steeply at the toe-region, possibly implying a greater amount of collagen. This study improves the knowledge about elastic, viscoelastic and failure properties of the knee ligaments and PT.  相似文献   
6.
Electromechanical delay (EMD) in isometric contractions of knee extensors evoked by voluntary, tendon reflex (TR) and electrical stimulation (ES) was investigated in 21 healthy young subjects. The subject performed voluntary knee extensions with maximum effort (maximal voluntary contraction, MVC), and at 30%, 60% and 80% MVC. Patellar tendon reflexes were evoked with the reflex hammer being dropped from 60°, 75° and 90° positions. In the percutaneous ES evoked contractions, single switches were triggered with pulses of duration 1.0 ms and of intensities 90, 120 and 150 V. Electromyograms of the vastus lateralis and rectus femoris muscles were recorded using surface electrodes. The isometric knee extension force was recorded using a load cell force transducer connected to the subject's lower leg. The major finding of this study was that EMD of the involuntary contractions [e.g. mean 22.1 (SEM 1.32) ms in TR 90°; mean 17.2 (SEM 0.62) ms in ES 150 V] was significantly shorter than that of the voluntary contractions [e.g. mean 38.7 (SEM 1.18) ms in MVC,P < 0.05]. The relationships between EMD, muscle contractile properties and muscle fibre conduction velocity were also investigated. Further study is needed to explain fully the EMD differences found between the voluntary and involuntary contractions.  相似文献   
7.
By virtue of their size, functional group diversity, and complex structure, proteins can often recognize and modulate disease‐relevant macromolecules that present a challenge to small‐molecule reagents. Additionally, high‐throughput screening and evolution‐based methods often make the discovery of new protein binders simpler than the analogous small‐molecule discovery process. However, most proteins do not cross the lipid bilayer membrane of mammalian cells. This largely limits the scope of protein therapeutics and basic research tools to those targeting disease‐relevant receptors on the cell surface or extracellular matrix. Previously, researchers have shown that cationic resurfacing of proteins can endow cell penetration. However, in our experience, many proteins are not amenable to such extensive mutagenesis. Here, we report that nanobodies—a small and stable protein that can be evolved to recognize virtually any disease‐relevant receptor—are amenable to cationic resurfacing, which results in cell internalization. Once internalized, these nanobodies access the cytosol. Polycationic resurfacing does not appreciably alter the structure, expression, and function (target recognition) of a previously reported GFP‐binding nanobody, and multiple nanobody scaffolds are amenable to polycationic resurfacing. Given this, we propose that polycationic resurfaced cell‐penetrating nanobodies might represent a general scaffold for intracellularly targeted protein drug discovery.  相似文献   
8.
<正> Ceramics are good alternative to metal as bearing couple materials because of their better wear resistance. A Finite Element(FE) study was performed to investigate the contact mechanics and stress distribution of Ceramic-on-Ceramic (COC) hip resurfacingprostheses. It was focused in particular on a parametric study to examine the effects of radial clearance, loading,alumina coating on the implants, bone quality, and fixation of cup-bone interface. It was found that a reduction in the radialclearance had the most significant effect on the predicted contact pressure distribution among all of the parameters considered inthis study. It was determined that there was a significant influence of non-metallic materials, such as the bone underneath thebearing components, on the predicted contact mechanics. Stress shielding within the bone tissue was found to be a major concernwhen regarding the use of ceramic as an alternative to metallic resurfacing prostheses. Therefore, using alumina implantswith a metal backing was found to be the best design for ceramic resurfacing prostheses in this study. The loading, bone quality,and acetabular cup fixation conditions were found to have only minor effects on the predicted contact pressure distribution alongthe bearing surfaces.  相似文献   
9.
The effect of femoral component malrotation on patellar biomechanics   总被引:1,自引:0,他引:1  
Patellofemoral complications are among the important reasons for revision knee arthroplasty. Femoral component malposition has been implicated in patellofemoral maltracking, which is associated with anterior knee pain, subluxation, fracture, wear, and aseptic loosening. Rotating-platform mobile bearings compensate for malrotation between the tibial and femoral components and may, therefore, reduce any associated patellofemoral maltracking. To test this hypothesis, we developed a dynamic model of quadriceps-driven open-kinetic-chain extension in a knee implanted with arthroplasty components. The model was validated using tibiofemoral and patellofemoral kinematics and forces measured in cadaver knees. Knee kinematics and patellofemoral forces were measured after simulating malrotation (±3°) of the femoral component. Rotational alignment of the femoral component affected tibial rotation near full extension and tibial adduction at higher flexion angles. External rotation of the femoral component increased patellofemoral lateral tilt, lateral shift, and lateral shear forces. Up to 21° of bearing rotation relative to the tibia was noted in the rotating-bearing condition. However, the rotating bearing had minimal effect in reducing the patellofemoral maltracking or shear induced by femoral component rotation. The rotating platform does not appear to be forgiving of malalignment of the extensor mechanism resulting from femoral component malrotation. These results support the value of improving existing methodologies for accurate femoral component alignment in total knee arthroplasty.  相似文献   
10.
目的:比较改良张力带钢丝内固定和传统张力带钢丝内固定治疗髌骨横行骨折术后关节面对合的效果。方法:2007年3月至2011年9月,分别采用胥氏张力带钢丝内固定和改良张力带钢丝内固定且随访超过1年的髌骨横行骨折的患者64例,术中分别采用胥氏张力带钢丝内固定和改良张力带钢丝内固定治疗,随访时行膝关节X线摄片检查,观察关节面对合情况,比较两种治疗方法所致关节面台阶样错位是否大于2mm的差异。结果:64例患者均获得随访,随访时间8~18个月,平均13.2个月,骨折端均愈合,两组Lysholm评分比较无统计学意义(P=0.665);胥氏张力带钢丝内固定组和改良张力带钢丝内固定组分贝出现1例(3.1%)和7例(21.9%)关节面台阶征,两组关节面台阶征的发生率比较差异有统计学意义(P=0.036)。结论:胥氏张力带钢丝固定法使髌骨骨折术后固定作用加强,关节面对合更好,能有效预防因台阶征引起的创伤性关节炎的发生。  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号