首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   9篇
  免费   1篇
  2019年   2篇
  2016年   1篇
  2013年   1篇
  2010年   2篇
  2008年   2篇
  2007年   2篇
排序方式: 共有10条查询结果,搜索用时 31 毫秒
1
1.
2.
Biomolecules are often purified via solvent gradient batch chromatography. Typically suitable smooth linear solvent gradients are applied to obtain the separation between the desired component and hundreds of impurities. The desired product is usually intermediate between weakly and strongly adsorbing impurities, and therefore a central cut is required to get the desired pure product. The stationary phases used for preparative and industrial separations have a low efficiency due to strong axial dispersion and strong mass transfer resistances. Therefore a satisfactory purification often cannot be achieved in a single chromatographic step. For large scale productions and for very valuable molecules, countercurrent operation such as the well known SMB process, is needed in order to increase separation efficiency, yield and productivity. In this work a novel multicolumn solvent gradient purification process (MCSGP-process) is introduced, which combines two chromatographic separation techniques, which are solvent gradient batch and continuous countercurrent SMB. The process consists of several chromatographic columns, which are switched in position opposite to the flow direction. Most of the columns are equipped with a gradient pump to adjust the modifier concentration at the column inlet. Some columns are interconnected, so that non pure product streams are internally, countercurrently recycled. Other columns are short circuited and operate in batch mode. As a working example the purification of an industrial stream containing 46% of the hormone Calcitonin is considered. It is found that for the required purity the MCSGP unit achieves a yield close to 100% compared to a maximum value of a single column batch chromatography of 66%.  相似文献   
3.
Multicolumn countercurrent solvent gradient purification (MCSGP) is a continuous chromatographic process developed in recent years (Aumann and Morbidelli, 2007a; Aumann et al., 2007) that is particularly suited for applications in the field of bioseparations. Like batch chromatography, MCSGP is suitable for three-fraction chromatographic separations and able to perform solvent gradients but it is superior in terms of solvent consumption, yield, purity, and productivity due to the countercurrent movement of the liquid and the solid phases. In this work, the MCSGP process is applied to the separation of three monoclonal antibody variants on a conventional preparative cation exchange resin. The experimental process performance was compared to simulations based on a lumped kinetic model. Yield and purity values of the target variant of 93%, respectively were obtained experimentally. The batch reference process was clearly outperformed by the MCSGP process.  相似文献   
4.
The charged monoclonal antibody (mAb) variants of the commercially available therapeutics Avastin®, Herceptin® and Erbitux® were separated by ion‐exchange gradient chromatography in batch and continuous countercurrent mode (MCSGP process). Different stationary phases, buffer conditions and two MCSGP configurations were used in order to demonstrate the broad applicability of MCSGP in the field of charged protein variant separation. Batch chromatography and MCSGP were compared with respect to yield, purity, and productivity. In the case of Herceptin®, also the biological activity of the product stream was taken into account as performance indicator. The robustness of the MCSGP process against feed composition variations was confirmed experimentally and by model simulations. Biotechnol. Bioeng. 2010;107:652–662. © 2010 Wiley Periodicals, Inc.  相似文献   
5.
A two‐step chromatography process for monoclonal antibody (mAb) purification from clarified cell culture supernatant (cCCS) was developed using cation exchange Multicolumn Countercurrent Solvent Gradient Purification (MCSGP) as a capture step. After an initial characterization of the cell culture supernatant the capture step was designed from a batch gradient elution chromatogram. A variety of chromatographic materials was screened for polishing of the MCSGP‐captured material in batch mode. Using multi‐modal anion exchange in bind‐elute mode, mAb was produced consistently within the purity specification. The benchmark was a state‐of‐the‐art 3‐step chromatographic process based on protein A, anion and cation exchange stationary phases. The performance of the developed 2‐step process was compared to this process in terms of purity, yield, productivity and buffer consumption. Finally, the potential of the MCSGP process was investigated by comparing its performance to that of a classical batch process that used the same stationary phase. Biotechnol. Bioeng. 2010;107: 974–984. © 2010 Wiley Periodicals, Inc.  相似文献   
6.
The semicontinuous twin‐column multicolumn countercurrent solvent gradient purification (MCSGP) process improves the trade‐off between purity and yield encountered in traditional batch chromatography, while its complexity, in terms of hardware requirements and process design, is reduced in comparison to process variants using more columns. In this study, the MCSGP process is experimentally characterized, specifically with respect to its unique degrees of freedom, i.e., the four switching times, which alternate the columns between interconnected and batch states. By means of isolation of the main charge isoform of an antibody, it is shown that purity is determined by the selection of the product collection window with negligible influence from the recycle phases. In addition, the amount of weak and strong impurities can be specifically attributed to the start and end of the collection, respectively. Due to higher abundance of weakly adsorbing impurities, the start of product collection influences productivity and yield more than the other switching times. Furthermore, most of the encountered tendencies scale between different loadings. The found trends can be rationalized from the corresponding batch chromatogram and therefore used during process design to obtain desirable process performances without extensive trial‐and‐error experimentation or complete model development and calibration.  相似文献   
7.
The novel "multicolumn countercurrent solvent gradient purification" (MCSGP) process has been modeled for the purification of a polypeptide mixture characterized by a strong non-linear competitive adsorption isotherm. As a model system, the purification of an industrial polypeptide mixture containing 46% of the hormone calcitonin has been selected. The many impurities contained in the mixture have been lumped into three key impurities, which are selected as the ones eluting closer to the main component. The simulation model allows for a better understanding of the complex operating behavior of the multicolumn system, which has been experimentally investigated in a previous work. Through a systematic parametric analyses of the model behavior, the main operating parameters controlling the process performance in terms of purity and yield are investigated. The study of internal liquid and adsorbed phase concentration profiles along the unit for the different operating conditions allow elucidating the working principle of the new separation process. It is found that the MCSGP unit achieves much higher yields for a given product purity than the corresponding single-column batch units.  相似文献   
8.
The economic advantages of continuous processing of biopharmaceuticals, which include smaller equipment and faster, efficient processes, have increased interest in this technology over the past decade. Continuous processes can also improve quality assurance and enable greater controllability, consistent with the quality initiatives of the FDA. Here, we discuss different continuous multi‐column chromatography processes. Differences in the capture and polishing steps result in two different types of continuous processes that employ counter‐current column movement. Continuous‐capture processes are associated with increased productivity per cycle and decreased buffer consumption, whereas the typical purity‐yield trade‐off of classical batch chromatography can be surmounted by continuous processes for polishing applications. In the context of continuous manufacturing, different but complementary chromatographic columns or devices are typically combined to improve overall process performance and avoid unnecessary product storage. In the following, these various processes, their performances compared with batch processing and resulting product quality are discussed based on a review of the literature. Based on various examples of applications, primarily monoclonal antibody production processes, conclusions are drawn about the future of these continuous‐manufacturing technologies.  相似文献   
9.
The recently developed continuous Multicolumn Countercurrent Solvent Gradient Purification (MCSGP) Process has been reduced to a fully equivalent semicontinuous setup with only three chromatographic columns and three gradient pump modules. Actually the 3-column MCSGP unit can even achieve better performance than the original 6-column process due to an additional degree of freedom, that is a different switching time for the "batch lane" and the "interconnected lane." Experimental results for the 3-column MCSGP unit of the purification of an industrial multicomponent peptide mixture containing 46% of Calcitonin on a reversed phase resin are compared with model simulations. It is concluded, that the model is well suited to predict the system behavior and therefore to design its optimal operating conditions.  相似文献   
10.
Intensified processing and end‐to‐end integrated continuous manufacturing are increasingly being considered in bioprocessing as an alternative to the current batch‐based technologies. Similar approaches can also be used at later stages of the production chain, such as in the post‐translational modifications that are often considered for therapeutic proteins. In this work, a process to intensify the enzymatic digestion of immunoglobulin G (IgG) and the purification of the resulting Fab fragment is developed. The process consists of the integration of a continuous packed‐bed reactor into a multicolumn chromatographic process. The integration is realized through the development of a novel multicolumn countercurrent solvent gradient purification (MCSGP) process, which, by adding a third column to the classical two‐column MCSGP process, allows for continuous loading and then straight‐through processing of the mixture leaving the reactor.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号