Contact allergy to implantable cardiac defibrillators (ICD) is an uncommon and underdiagnosed complication. We report a case of a 20-years-old man patient that was resuscitated from sudden cardiac death. Workup imaging study was unremarkable, but genetic testing identified a mutation in the KCNH2 gene of uncertain significance. The patient underwent a subcutaneous implantable cardiac defibrillator (S-ICD) implantation, with no complications. The patient suffered two hospital re-admissions due to a device-related inflammatory reaction, leading to two device re-implantations. At the first time, it was considered a bacterial infection and the S-ICD was replaced by an endovascular device. At the second time, a tissue-device interaction, with hypersensitivity reaction and device rejection was suspected. The skin patch-tests were inconclusive, but it was decided to implant a custom-made gold-coated endovascular ICD. Indeed, the tendency is an initial misdiagnosis as an infection and a high clinical suspicion is essential to an early diagnosis.  相似文献   
2.
Implantable cardioverter-defibrillators (ICDs) terminate ventricular tachycardia (VT) and ventricular fibrillation (VF) with high efficacy and can protect patients from sudden cardiac death (SCD). However, inappropriate shocks may occur if tachycardias are misdiagnosed. Inappropriate shocks are harmful and impair patient quality of life. The risk of inappropriate therapy increases with lower detection rates programmed in the ICD. Single-chamber detection poses greater risks for misdiagnosis when compared with dual-chamber devices that have the benefit of additional atrial information. However, using a dual-chamber device merely for the sake of detection is generally not accepted, since the risks associated with the second electrode may outweigh the benefits of detection. Therefore, BIOTRONIK developed a ventricular lead called the LinoxSMART S DX, which allows for the detection of atrial signals from two electrodes positioned at the atrial part of the ventricular electrode. This device contains two ring electrodes; one that contacts the atrial wall at the junction of the superior vena cava (SVC) and one positioned at the free floating part of the electrode in the atrium. The excellent signal quality can only be achieved by a special filter setting in the ICD (Lumax 540 and 740 VR-T DX, BIOTRONIK). Here, the ease of implantation of the system will be demonstrated.  相似文献   
3.
Intrinsic anti-tachycardia pacing (iATP) is a novel automated ATP algorithm that employs post-pacing interval (PPI) to design the next ATP sequence based on an analysis of the prior failed ATP sequence. A patient with hypertrophic cardiomyopathy received an implantable cardioverter-defibrillator (ICD) (Cobalt™ XT DR, Medtronic, Minneapolis, MN, USA) following an episode of syncope due to macro-reentrant ventricular tachycardia (VT) (right bundle branch block configuration, cycle length [CL] 280 ms). The VF zone was set to VTCL <300 ms and iATP therapy was prescribed before and during capacitor charging. The iATP was initiated when VT recurred 3 months later. The first attempt with an assumption of 150 ms propagation time from the pacing site to the VT circuit (9 pulses) could not reset the VT, leaving a PPI of 650 ms. A subsequent attempt involving 20 pulses with an assumption of 250 ms propagation time terminated the VT. Failure to reach the circuit is a major cause of unsuccessful ATP. In this regard, iATP is expected to have theoretical advantages over empirical and traditional ATP therapies. To the best of our knowledge, this is the first intracardiac electrogram illustrating how automated precision ATP terminates VT in a clinical setting.  相似文献   
4.
With the recent development of retinal prostheses, it is important to develop reliable techniques for assessing the safety of these devices in preclinical studies. However, the standard fixation, preparation, and automated histology procedures are not ideal. Here we describe new procedures for evaluating the health of the retina directly adjacent to an implant. Retinal prostheses feature electrode arrays in contact with eye tissue. Previous methods have not been able to spatially localize the ocular tissue adjacent to individual electrodes within the array. In addition, standard histological processing often results in gross artifactual detachment of the retinal layers when assessing implanted eyes. Consequently, it has been difficult to assess localized damage, if present, caused by implantation and stimulation of an implanted electrode array. Therefore, we developed a method for identifying and localizing the ocular tissue adjacent to implanted electrodes using a (color-coded) dye marking scheme, and we modified an eye fixation technique to minimize artifactual retinal detachment. This method also rendered the sclera translucent, enabling localization of individual electrodes and specific parts of an implant. Finally, we used a matched control to increase the power of the histopathological assessments. In summary, this method enables reliable and efficient discrimination and assessment of the retinal cytoarchitecture in an implanted eye.  相似文献   
5.

Background

Implantable cardioverter defibrillators (ICDs) are designed to deliver shocks or antitachycardia pacing (ATP) in the event of ventricular arrhythmias. During follow-up, some ICD recipients experience the sensation of ICD discharge in the absence of an actual discharge (phantom shock). The aim of this study was to evaluate the incidence and predictors of phantom shocks in ICD recipients.

Methods

Medical records of 629 consecutive patients with ischaemic or dilated cardiomyopathy and prior ICD implantation were studied.

Results

With a median follow-up of 35 months, phantom shocks were reported by 5.1 % of ICD recipients (5.7 % in the primary prevention group and 3.7 % for the secondary prevention group; p=NS). In the combined group of primary and secondary prevention, there were no significant predictors of the occurrence of phantom shocks. However, in the primary prevention group, phantom shocks were related to a history of atrial fibrillation (p=0.03) and NYHA class <III (p=0.05). In the secondary prevention group, there were no significant predictors for phantom shocks.

Conclusion

Phantom shocks occur in approximately 5 % of all ICD recipients. In primary prevention patients, a relation with a history of atrial fibrillation and NYHA class <III were significant predictors for the occurrence of phantom shocks. In the secondary prevention patients, no significant predictors were found.  相似文献   
6.

Purpose

Based on multiple large clinical trials conducted over the last decades guidelines for implantable cardioverter-defibrillator (ICD) implantations have been evolving. The increase in primary prophylactic ICD implantations challenges us to be critical towards the indications in certain patient populations.

Methods

We retrospectively collected patient characteristics and rates of appropriate and inappropriate ICD therapy, appropriate and inappropriate ICD shock and mortality of all patients who received an ICD in the University Medical Center Utrecht (UMCU) over the years 2006–2011.

Results

A total of 1075 patients were included in this analysis (74 % male, mean age 61 ± 13 years, left ventricular ejection fraction 30 ± 13 %); 61 % had a primary indication and 58 % had ischaemic heart disease. During a mean follow-up period of 31 ± 17 months, 227 of the patients (21 %) received appropriate ICD therapy (149 (14 %) patients received an appropriate ICD shock). Females, patients with a primary prophylactic indication and patients with non-ischaemic heart disease experienced significantly less ICD therapy. Only a few patients (54, 5 %) received inappropriate ICD therapy; 33 (3 %) patients received an inappropriate ICD shock. Fifty-five patients died within one year after ICD implantation and were therefore, in retrospect, not eligible for ICD implantation.

Conclusion

Our study confirms the benefit of ICD implantation in clinical practice. Nevertheless, certain patients experience less benefit than others. A more patient-tailored risk stratification based on electrophysiological parameters would be lucrative to improve clinical benefit and cost-effectiveness.  相似文献   
7.
8.
9.
Patients with LQT syndrome are prone to lifethreatening arrhythmias. After surviving such an event, implantation of an ICD is indicated. There are, however, special subtle demands in the treatment of these patients. In this case report we describe our findings in a patient with LQT1 syndrome, and the pitfalls that can and must be avoided. (Neth Heart J 2007;15:418-21.)  相似文献   
10.
Implantable prosthetic devices can often affect the recipient's hemostasis, with possible hemolysis and thrombus formation. Since such devices can produce turbulent flow, it is important to characterize it as accurately as possible, by means of the Reynolds stress tensor. Some parameters related to the latter have been often used to provide a quantity related to the possible damage to blood constituents: the TSSmax, for instance, has been associated with hemolysis. It can be expressed as TSSmax=(σ1−σ3)/2, σ1 and σ3 being the highest and lowest principal normal stresses (PNSs) in each point of the flow.

In the present work, the average value of the shear stress over a spherical surface, representative of a blood component, is derived. All three PNSs (σ1, σ2 and σ3) are found to have an equal role in the determination of this parameter, since the relative formula shows a marked symmetry with respect to the PNSs. The average shear stress level, for a given (σ1, σ3) pair (hence, for a given TSSmax), has a minimum and maximum value, depending on the particular σ2 value yielded by the local structure of the turbulent flow field. A numerical investigation on more complex geometries shows similar results. The role of the intermediate PNS is thus shown for the first time to have a physical relevance. The presented results can be useful whenever a spatial averaging of the shear field is important to be assessed, such as in the case of platelet activation. A new parameter is thus proposed, which can be correlated with prosthetic devices complications.  相似文献   