首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   80篇
  免费   8篇
  2022年   1篇
  2021年   1篇
  2020年   2篇
  2019年   5篇
  2018年   3篇
  2017年   2篇
  2016年   4篇
  2015年   5篇
  2014年   5篇
  2013年   30篇
  2010年   2篇
  2009年   4篇
  2008年   1篇
  2006年   3篇
  2005年   4篇
  2004年   1篇
  2002年   1篇
  2001年   1篇
  2000年   1篇
  1999年   2篇
  1998年   2篇
  1997年   2篇
  1996年   3篇
  1995年   1篇
  1989年   1篇
  1978年   1篇
排序方式: 共有88条查询结果,搜索用时 15 毫秒
1.
The effect of repeated conditioning procedures (25 runs), consisting of soiling (milk and meat products) and cleaning steps, on the hygienic status, physico-chemical properties and surface chemical composition of stainless steel (SS) surfaces, was investigated. Five SSs differing in grade and finish were used. Both soiling and surface cleaning/conditioning procedures resulted in a similar increase in the surface contamination with carbon, while the changes in the basic component of the surface free energy depended on the conditioning procedure. The passive film was also affected, the Fe/Cr ratio in particular. The hygienic status was also changed, especially with milk as shown by monitoring the number of residual adhering Bacillus cereus spores after contaminating the surface with spores followed by cleaning. The results show that in food environments, the presence and the nature of conditioning molecules play a major role in the hygienic status of SS surfaces.  相似文献   
2.
Abstract

This article describes an electrochemical method to remove bacterial biofilm from a stainless steel (SS) surface using a potential pulse/reverse pulse technique. This technique employs a periodic waveform that consists of anodic and cathodic pulses. The pulses can effectively strip a thin layer of metal off the SS surface, along with the adherent biofilm, in a saline solution. Not only can the pulses effectively remove biofilm from the SS surface, but they also regenerate the original mirror-like shiny surface. The importance of this electrochemical biofilm removal method is its wide applicability for any types of biofilms. That is, instead of directly removing the biofilm, it removes a very thin layer of the metal under the biofilm. Thus, the removal process is independent to the nature of the biofilms. Furthermore, this electrochemical biofilm removal method is rapid (less than 30?s of potential pulse time) and does not require hazardous chemicals.  相似文献   
3.
4.
This investigation examined the effects of common aqueous biocides and disinfectant foams derived from them on Pseudomonas aeruginosa biofilms. Biofilms were grown on stainless steel coupons under standardised conditions in a reactor supplemented with low concentrations of organic matter to simulate conditions prevalent in industrial systems. Five-day-old biofilms formed under ambient conditions with continuous agitation demonstrated a low coefficient of variation (5.809%) amongst viable biofilm bacteria from independent trials. Scanning electron microscopy revealed biofilms on coupons with viable biofilm bacteria observed by confocal microscopy. An aqueous solution of a common foaming agent amine oxide (AO) produced negligible effects on bacterial viability in biofilms (p?>?0.05). However, significant biofilm inactivation was noted with aqueous solutions of common biocides (peracetic acid, sodium hypochlorite, sodium ethylenediaminetetraacetic acid) with or without AO (p?<?0.05). Aereation of a mixture of AO with each of these common biocides resulted in significant reductions in the viability of biofilm bacteria (p?<?0.05). In contrast, limited effects were noted by foam devoid of biocides. A relationship between microbial inactivation and the concentration of biocide in foam (ranging from 0.1?–?0.5%) and exposure period were noted (p?<?0.05). Although, lower numbers of viable biofilm bacteria were recovered after treatment with the disinfectant foam than by the cognate aqueous biocide, significant differences between these treatments were not evident (p?>?0.05). In summary, the studies revealed significant biofilm inactivation by biocidal foam prepared with common biocides. Validation of foam disinfectants in controlled trials at manufacturing sites may facilitate developments for clean in place applications. Advantages of foam disinfectants include reductions in the volumes of biocides for industrial disinfection and in their disposal after use.  相似文献   
5.
The aim of this study was to analyze the cleaning efficiency of polysaccharidases and proteolytic enzymes against biofilms of bacterial species found in food industry processing lines and to study enzyme effects on the composition of extracellular polymeric substances (EPS) and biofilm removal in a Clean-in-Place (CIP) procedure. The screening of 7 proteases and polysaccharidases for removal of biofilms of 16 bacterial species was first evaluated using a microtiter plate assay. The alkaline pH buffer removed more biofilm biomass as well as affecting a larger range of bacterial species. The two serine proteases and α-amylase were the most efficient enzymes. Proteolytic enzymes promoted biofilm removal of a larger range of bacterial species than polysaccharidases. Using three isolates derived from two bacterial species widely found in food processing lines (Pseudomonas fluorescens and the Bacillus cereus group), biofilms were developed on stainless steel slides and enzymatic solutions were used to remove the biofilms using CIP procedure. Serine proteases were more efficient in removing cells of Bacillus biofilms than polysaccharidases. However, polysaccharidases were more efficient in removing P. fluorescens biofilms than serine proteases. Solubilization of enzymes with a buffer containing surfactants, and dispersing and chelating agents enhanced the efficiency of polysaccharidases and proteases respectively in removing biofilms of Bacillus and P. fluorescens. A combination of enzymes targeting several components of EPS, surfactants, dispersing and chelating agents would be an efficient alternative to chemical cleaning agents.  相似文献   
6.
The present study evaluated biofilm growth in AISI 316L stainless steel tubes for seawater-cooled exchanger-condensers that had four different arithmetic mean surface roughness values ranging from 0.14 μm to 1.2 μm. The results of fluid frictional resistance and heat transfer resistance regarding biofilm formation in the roughest surface showed increases of 28.2% and 19.1% respectively, compared with the smoothest surface. The biofilm thickness taken at the end of the experiment showed variations of up to 74% between the smoothest and roughest surfaces. The thermal efficiency of the heat transfer process in the tube with the roughest surface was 17.4% greater than that in the tube with the smoothest surface. The results suggest that the finish of the inner surfaces of the tubes in heat exchanger-condensers is critical for improving energy efficiency and avoiding biofilm adhesion. This may be utilised to reduce biofilm adhesion and growth in the design of heat exchanger-condensers.  相似文献   
7.
Aims: To investigate the presence of a relationship between the strength of attachment of Pseudomonas aeruginosa to stainless steel surfaces and their observed multiple drug resistance. Methods and Results: Multiple drug resistance of clinical and environmental isolates of Ps. aeruginosa was evaluated using disc diffusion method. The blot succession technique was used to quantify the strength of attachment of Ps. aeruginosa isolates. Different multiple drug–resistant Ps. aeruginosa isolates exhibited variable attachment strength. Although the highest multiple drug–resistant clinical isolate was shown to have the least attachment strength among clinical isolates, a weak correlation was found between attachment strength and multiple resistance among our investigated Ps. aeruginosa isolates. Conclusions: There is a weak correlation between multiple drug resistance and strength of attachment to stainless steel surfaces. Significance and Impact of the Study: Even low‐resistant Ps. aeruginosa could have the potential of attaching firmly to surfaces and forming biofilm.  相似文献   
8.
9.
Stainless steel is a ubiquitous surface in therapeutic protein production equipment and is also present as the needle in pre‐filled syringe biopharmaceutical products. Stainless steel microparticles can cause the aggregation of a monoclonal antibody (mAb). The initial rate of mAb aggregation was second order in steel surface area and zero order in mAb concentration, generally consistent with a bimolecular surface aggregation being the rate‐limiting step. Polysorbate 20 (PS20) suppressed the aggregation yet was unable to desorb the firmly bound first layer of protein that adsorbs to the stainless steel surface. Also, there was no exchange of mAb from the first adsorbed layer to the bulk phase, suggesting that the aggregation process actually occurs on subsequent adsorption layers. No oxidized Met residues were detected in the mass spectrum of a digest of a highly aggregated mAb, although there was a fourfold increase in carbonyl groups due to protein oxidation. Biotechnol. Bioeng. 2010;105: 121–129. © 2009 Wiley Periodicals, Inc.  相似文献   
10.
目的通过对临床病例的研究,比较减速镍钛机扩和普通不锈钢K型锉清洁根管的能力。方法选取临床需要根管治疗的患牙60例,随机分为2组,经开髓拨髓后分别用镍钛减速机扩和不锈钢K型及H型锉进行根管预备,预备完成后用灭菌棉捻擦拭管壁,作微生物检查。结果2组方法扩锉后对根管内微生物的变化做统计学分析,差异有显著性(P<0.05)。结论镍钛减速机扩对根管的清洁能力高于普通不锈钢扩锉,值得临床的推广。  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号