首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   22篇
  免费   1篇
  2019年   2篇
  2018年   3篇
  2017年   4篇
  2016年   1篇
  2015年   2篇
  2014年   1篇
  2013年   4篇
  2012年   1篇
  2011年   1篇
  2009年   2篇
  2007年   1篇
  2006年   1篇
排序方式: 共有23条查询结果,搜索用时 31 毫秒
1.
TAVI devices are manufactured with cylindrical frames. However, the frames are rarely cylindrical post-deployment since deformation due to localised under expansion can be induced by calcified material on the native valve leaflets exerting irregular forces upon the frame. Consequently, the leaflets within a deformed TAVI device may undergo elevated stress during operation, which may lead to premature device failure.Using computational analysis a complete TAVI device model was simulated undergoing deployment into an aortic root model derived from CT data for a patient with severe calcific aortic stenosis, followed by a pressure simulated cardiac cycle. The complete analysis was performed eight times, each with the device at a different rotational orientation relative to the native valve, with an increment spacing of 15°.The TAVI device frames consistently featured significant distortions associated with bulky calcified material at the base of the non-coronary sinus. It was found that the average von Mises stress in the prosthetic valves was only increased in one of the cases relative to an idealised device. However, the maximum von Mises stress in the prosthetic valves was elevated in the majority of the cases.Furthermore, it was found that there were preferable orientations to deploy the prosthetic device, in this case, when the prosthetic leaflets were aligned with the native leaflets. As device orientation deviated from this orientation, the stresses in the valve increased because the distance between the prosthetic commissures decreased. This potentially could represent a sufficient increase in stress to induce variation in device lifespan.  相似文献   
2.
Abstract

Objectives: The purpose of the present study was to evaluate the distribution and magnitude of stresses through the bone tissue surrounding Morse taper dental implants at different positioning relative to the bone crest. Materials and Methods: A mandibular bone model was obtained from a computed tomography scan. A three-dimensional (3D) model of Morse taper implant-abutment systems placed at the bone crest (equicrestal) and 2?mm bellow the bone crest (subcrestal) were assessed by finite element analysis (FEA). FEA was carried out on axial and oblique (45°) loading at 150 N relatively to the central axis of the implant. The von Mises stresses were analysed considering magnitude and volume of affected peri-implant bone. Results: On vertical loading, maximum von Mises stresses were recorded at 6-7?MPa for trabecular bone while values ranging from 73 up to 118?MPa were recorded for cortical bone. On oblique loading at the equiquestral or subcrestal positioning, the maximum von Mises stresses ranged from 15 to 21?MPa for trabecular bone while values at 150?MPa were recorded for the cortical bone. On vertical loading, >99.9vol.% cortical bone volume was subjected to a maximum of 2?MPa while von Mises stress values at 15?MPa were recorded for trabecular bone. On oblique loading, >99.9vol.% trabecular bone volume was subjected to maximum stress values at 5?MPa, while von Mises stress values at 35?MPa were recorded for >99.4vol.% cortical bone. Conclusions: Bone volume-based stress analysis revealed that most of the bone volume (>99% by vol) was subjected to significantly lower stress values around Morse taper implants placed at equicrestal or subcrestal positioning. Such analysis is commentary to the ordinary biomechanical assessment of dental implants concerning the stress distribution through peri-implant sites.  相似文献   
3.
Abstract

The success rate of reconstructing the Anterior Cruciate Ligament (ACL) with prosthetic ligaments is currently low both in humans and animals. The stress distribution in prosthetic ligaments that causes failure is very complex and not yet understood. Therefore, we have begun to develop a Finite Element Model of a prosthetic ACL. Here we describe the normal and contact stresses in DacronTM yarn (a multi-fibrillar structure) using input data based on experimental measurements of the load and strain of six designed yarns.

The results show that the normal and contact stresses in the fibres of the ACL yarn are directly proportional to the yam strains. Increasing the twisting length (transverse deformation) of the yarn increases the normal stress in the fibres and the yarn modulus, but decreases the contact stresses between the fibres. The structural properties of a yarn are dependent on the specific arrangement of various filament types. Increasing the distance between the longitudinal (symmetry) axes of the filaments and the axis of symmetry of the yarn decreases the stresses.  相似文献   
4.
Mechanical loading through youth exercise is highly modifiable and represents a strategy to maximize peak adult bone mass, with the potential for broad implementation across the population to lower fracture risk. For girls, circum-menarcheal growth is critical, with around 50% of adult bone acquired over a 4-year period. Here, we prospectively followed 10 gymnasts and 12 age-matched non-gymnasts across approximately 4 years circum-menarche. A combination of pQCT and subject-specific finite element models were used to measure differences in bone acquisition and structure between the groups, and to determine the degree to which specific mechanical factors predict change in bone structure. At baseline, gymnasts had stronger bone, including 26% higher BMC, 51% greater compressive strength, and 21% higher trabecular density. Over the study period, both groups more than doubled their bone strength. Pre-menarcheal principal stresses predicted change in pQCT variables for non-gymnasts, but not gymnasts. The bone of non-gymnasts became more asymmetrical than the bone of gymnasts. Our results suggest that exposure to the diverse, intense mechanical signals of gymnastic loading during adolescence imparts substantial benefits to bone geometry and mechanical function. Specifically, the bone of gymnasts is better able to resist loading from multiple directions, and operates with a higher factor of safety compared to non-gymnasts.  相似文献   
5.
Tonometry-based devices are valuable method for vascular function assessment and for measurement of blood pressure. However current design and calibration methods rely on simple models, neglecting key geometrical features, and anthropometric and property variability among patients. Understanding impact of these influences on tonometer measurement is thus essential for improving outcomes of current devices, and for proposing improved design. Towards this goal, we present a realistic computational model for tissue-device interaction using complete wrist section with hyperelastic material and frictional contact. Three different tonometry geometries were considered including a new design, and patient-specific influences incorporated via anthropometric and age-dependent tissue stiffness variations. The results indicated that the new design showed stable surface contact stress with minimum influence of the parameters analyzed. The computational predictions were validated with experimental data from a prototype based on the new design. Finally, we showed that the underlying mechanics of vascular unloading in tonometry to be fundamentally different from that of oscillatory method. Due to directional loading in tonometry, pulse amplitude maxima was observed to occur at a significantly lower compression level (around 31%) than previously reported, which can impact blood pressure calibration approaches based on maximum pulse pressure recordings.  相似文献   
6.
7.
Inappropriate lordotic angle of lumbar fusion cage could be associated with cage damage or subsidence. The biomechanical influence of cage lordotic angle on lumbar spine has not been fully investigated. Four surgical finite element models were constructed by inserting cages with various lordotic angles at L3-L4 disc space. The four motion modes were simulated. The range of motion (ROM) decreased with increased lordotic angle of cage in flexion, extension, and rotation, whereas it was not substantially changed in bending. The maximum stress in cage decreased with increased lordotic angle of cage in all motion modes. The maximum stress in endplate at surgical level increased with increased lordotic angle of cage in flexion and rotation, whereas it was not substantially changed in extension and bending. The facet joint force (FJF) was much smaller than that for the intact conditions in extension, bending, and rotation, while it was not substantially changed in flexion. In conclusion, the ROM, stresses in the cage and endplate at surgical level are sensitive to the lordotic angle of cage. The increased cage lordotic angle may provide better stability and reduce the risk of cage damage, whereas it may increase the risk of subsidence in flexion and rotation.  相似文献   
8.
In order to understand whole tooth behavior under load the biomechanical role of enamel and dentin has to be determined. We approach this question by comparing the deformation pattern and stiffness of intact teeth under load with the deformation pattern and stiffness of the same teeth after the enamel has been mechanically compromised by introducing a defect. FE models of intact human premolars, based on high resolution micro-CT scans, were generated and validated by in vitro electronic speckle pattern interferometry (ESPI) experiments. Once a valid FE model was established, we exploit the flexibility of the FE model to gain more insight into whole tooth function. Results show that the enamel cap is an intrinsically stiff biological structure and its morphology dictates the way a whole tooth will mechanically behave under load. The mechanical properties of the enamel cap were sufficient to mechanically maintain almost its entire stiffness function under load even when a small defect (cavity simulating caries) was introduced into its structure and breached the crown integrity. We conclude that for the most part, that enamel and not dentin dictates the mechanical behavior of the whole tooth.  相似文献   
9.
The widespread availability of three-dimensional imaging and computational power has fostered a rapid increase in the number of biologists using finite element analysis (FEA) to investigate the mechanical function of living and extinct organisms. The inevitable rise of studies that compare finite element models brings to the fore two critical questions about how such comparative analyses can and should be conducted: (1) what metrics are appropriate for assessing the performance of biological structures using finite element modeling? and, (2) how can performance be compared such that the effects of size and shape are disentangled? With respect to performance, we argue that energy efficiency is a reasonable optimality criterion for biological structures and we show that the total strain energy (a measure of work expended deforming a structure) is a robust metric for comparing the mechanical efficiency of structures modeled with finite elements. Results of finite element analyses can be interpreted with confidence when model input parameters (muscle forces, detailed material properties) and/or output parameters (reaction forces, strains) are well-documented by studies of living animals. However, many researchers wish to compare species for which these input and validation data are difficult or impossible to acquire. In these cases, researchers can still compare the performance of structures that differ in shape if variation in size is controlled. We offer a theoretical framework and empirical data demonstrating that scaling finite element models to equal force: surface area ratios removes the effects of model size and provides a comparison of stress-strength performance based solely on shape. Further, models scaled to have equal applied force:volume ratios provide the basis for strain energy comparison. Thus, although finite element analyses of biological structures should be validated experimentally whenever possible, this study demonstrates that the relative performance of un-validated models can be compared so long as they are scaled properly.  相似文献   
10.
Finite element analysis (FEA) is a widespread technique to evaluate the stress/strain distributions in teeth or dental supporting tissues. However, in most studies occlusal forces are usually simplified using a single vector (i.e., point load) either parallel to the long tooth axis or oblique to this axis. In this pilot study we show how lower first molar occlusal information can be used to investigate the stress distribution with 3D FEA in the supporting bone structure. The LM1 and the LP2‐LM1 of a dried modern human skull were scanned by μCT in maximum intercuspation contact. A kinematic analysis of the surface contacts between LM1 and LP2‐LM1 during the power stroke was carried out in the occlusal fingerprint analyzer (OFA) software to visualize contact areas during maximum intercuspation contact. This information was used for setting the occlusal molar loading to evaluate the stress distribution in the supporting bone structure using FEA. The output was compared to that obtained when a point force parallel to the long axis of the tooth was loaded in the occlusal basin. For the point load case, our results indicate that the buccal and lingual cortical plates do not experience notable stresses. However, when the occlusal contact areas are considered, the disto‐lingual superior third of the mandible experiences high tensile stresses, while the medio‐lingual cortical bone is subjected to high compressive stresses. Developing a more realistic loading scenario leads to better models to understand the relationship between masticatory function and mandibular shape and structures. Am J Phys Anthropol, 2012. © 2011 Wiley Periodicals, Inc.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号