首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   114篇
  免费   6篇
  国内免费   6篇
  2022年   1篇
  2021年   5篇
  2020年   4篇
  2019年   9篇
  2018年   5篇
  2017年   13篇
  2016年   7篇
  2015年   6篇
  2014年   6篇
  2013年   26篇
  2012年   6篇
  2011年   8篇
  2010年   1篇
  2009年   4篇
  2008年   4篇
  2007年   5篇
  2006年   2篇
  2005年   2篇
  2004年   1篇
  2003年   3篇
  2002年   1篇
  2001年   1篇
  2000年   2篇
  1996年   1篇
  1989年   1篇
  1988年   1篇
  1987年   1篇
排序方式: 共有126条查询结果,搜索用时 15 毫秒
1.
Factors affecting the viability and infectivity of an ectomycorrhizal fungus during moderate concentration by cross-flow filtration were determined. Mycelial suspensions were concentrated with three commercial membrane filters (Prostak Millipore Co., M14 Tech-Sep Co. and Ceraflo Norton Co.) under aseptic conditions. Medium components may reduce the filtration rate due to their low solubility. An antifoam agent did not reduce the average flux rates as much as did the malt extract. Clear unobstructed channels (I.D. 6mm) of the tubular modules (Tech-Sep) gave the best results both in terms of performance (filtration rate) and cell viability. Shear stresses caused by pumping and flow through narrow retentate channels were probably responsible for lowering viability and infectivity. There was no linear relationship between permeate fluxes and cell concentration. There is an optimum pore size both in terms of performance (filtration rate) and cell viability. Physical blockage of large pores by hyphae could explain lower permeate flux rates than those obtained with lower pore sizes membranes.  相似文献   
2.
Prostate cancer is the most common malignancy in men and the second leading cause of cancer-related death in men. Radiotherapy is a curative option that is administered via external beam radiation, brachytherapy, or in combination. Sexual dysfunction is a common toxicity following radiotherapy, similar to men undergoing radical prostatectomy, but the etiology is different. The pathophysiology of radiation-induced sexual dysfunction is multi-factorial, and the toxicity is a major cause of impaired quality of life among long-term prostate cancer survivors. Management of a patient’s sexual function during and after radiotherapy requires multidisciplinary coordination of care between radiation oncology, urology, psychiatry, pharmacy, and dermatology. This review provides a framework for clinicians to better understand prostatic radiotherapy-induced sexual dysfunction diagnosis, evaluation, and a patient-centered approach to toxicity preventive strategies and management.  相似文献   
3.
Abstract

This paper presents the process of designing a new elastic element replacing a membrane in the chamber stapes prosthesis (ChSP). The results of the study are volume displacement characteristics obtained for the prosthesis and physiological stapes. Simulation tests on a 3D CAD model have confirmed that a properly designed ring can stimulate perilymph with the same or greater efficacy as the physiological stapes footplate placed on the elastic annular ligament. The ChSP with a new elastic element creates a good chance of improving hearing in patients suffering from otosclerosis.  相似文献   
4.
It is always recommended to use more implants for supporting a prosthesis in the immediate loading condition than in the classical two-stage treatment procedure. By means of the finite element (FE) method, the influence of the number of implants used in immediately loaded fixed partial prosthesis (FPP) on the load distribution was investigated, considering the abutment geometry. Two 3D FE models were studied employing four implants to support a FPP in the premaxilla. One model was designed with straight abutments and the other with 20°-angled abutments. The results concerning implant displacements, stresses and strains were compared with those of two implant-supported FPPs, obtained in a previous study. A noticeable reduction in the determined biomechanical bone loading was observed with the use of more implants in supporting an immediately loaded prosthesis. This study confirms that the use of additional numbers of implants in an immediately loaded prosthesis is highly recommended.  相似文献   
5.
Tibial bone defect is a critical problem for revision knee arthroplasty. Instead of using metallic spacer or cement, biodegradable scaffolds could be an alternative solution. A numerical model of a revision knee arthroplasty was thus developed to estimate the mechanical resistance of the scaffold in this demanding situation. The tibia, scaffold, and prosthesis were represented by simplified parameterised geometries. The maximal gait cycle force was applied asymmetrically to simulate a critical loading. Several parameters were analysed: 1) inter-individual variability, 2) cortical bone stiffness, 3) cortical bone thickness, 4) prosthesis fixation quality, and 5) scaffold thickness. The calculated scaffold strain was compared to its experimental ultimate strain. Among the tested parameters, failure was only predicted with scaffold thickness below 5 mm. This study suggests that biodegradable bone scaffolds could be used to fill bone defects in revision knee arthroplasty, but scaffold size seems to be the limiting factor.  相似文献   
6.

Laryngectomized patients use indwelling silicone rubber voice prostheses, placed in a surgically created fistula in between the trachea and the esophagus, for voice and speech rehabilitation. At the esophageal side, these voice prostheses rapidly become colonized by a thick biofilm consisting of a variety of oral and skin bacteria and yeasts, and on average, after 3–4 months a prosthesis has to be replaced. In this study, the influence of caffeinated soft drinks on biofilm formation on silicone rubber voice prostheses has been investigated in a modified Robbins device. Robbins devices were first inoculated with the total cultivable microflora from an explanted voice prosthesis for 3 d, after which the devices were perfused three times daily over a 12 day period with 650 ml of either phosphate buffered saline or carbonated mineral water (controls), caffeinated soft drinks (two types), or a decaffeinated and a sugar‐free version of one of the caffeinated soft drinks. At the end of a day, during the experimental period, the devices were filled with growth medium for 30 min. Both caffeinated soft drinks reduced bacterial prevalence in the biofilms to 1–5% of the control, while yeasts thrived in voice prosthetic biofilms exposed to caffeinated soft drinks. Neither the controls, nor the decaffeinated soft drink, nor the sugar‐free version of this showed these effects on bacterial prevalence.  相似文献   
7.
The integrity of biofilms on voice prostheses used to rehabilitate speech in laryngectomized patients causes unwanted increases in airflow resistance, impeding speech. Biofilm integrity is ensured by extracellular polymeric substances (EPS). This study aimed to determine whether synthetic salivary peptides or mucolytics, including N-acetylcysteine and ascorbic acid, influence the integrity of voice prosthetic biofilms. Biofilms were grown on voice prostheses in an artificial throat model and exposed to synthetic salivary peptides, mucolytics and two different antiseptics (chlorhexidine and Triclosan). Synthetic salivary peptides did not reduce the air flow resistance of voice prostheses after biofilm formation. Although both chlorhexidine and Triclosan reduced microbial numbers on the prostheses, only the Triclosan-containing positive control reduced the air flow resistance. Unlike ascorbic acid, the mucolytic N-acetylcysteine removed most EPS from the biofilms and induced a decrease in air flow resistance.  相似文献   
8.
Through a parallel approach of tracking product quality through fermentation and purification development, a robust process was designed to reduce the levels of product-related species. Three biochemically similar product-related species were identified as byproducts of host-cell enzymatic activity. To modulate intracellular proteolytic activity, key fermentation parameters (temperature, pH, trace metals, EDTA levels, and carbon source) were evaluated through bioreactor optimization, while balancing negative effects on growth, productivity, and oxygen demand. The purification process was based on three non-affinity steps and resolved product-related species by exploiting small charge differences. Using statistical design of experiments for elution conditions, a high-resolution cation exchange capture column was optimized for resolution and recovery. Further reduction of product-related species was achieved by evaluating a matrix of conditions for a ceramic hydroxyapatite column. The optimized fermentation process was transferred from the 2-L laboratory scale to the 100-L pilot scale and the purification process was scaled accordingly to process the fermentation harvest. The laboratory- and pilot-scale processes resulted in similar process recoveries of 60 and 65%, respectively, and in a product that was of equal quality and purity to that of small-scale development preparations. The parallel approach for up- and downstream development was paramount in achieving a robust and scalable clinical process.  相似文献   
9.
In implantology, when financial or biological feasibility limitations appear, it is necessary to use prostheses with geometries that deviate from the conventional, with a pontic in the absence of an intermediate implant. The aim of this study was analyze and understand the general differences in the stresses generated in implants, components and infrastructures according to the configuration of the prosthesis over three or two implants. Thus, this paper analyzes the von Mises equivalent stresses (VMES) of ductile materials on their external surfaces. The experimental groups: Regular Splinted Conventional Group (RCG), which had conventional infrastructures on 3 regular-length Morse taper implants (4x11?mm); Regular Splinted Pontic Group (RPG), which had infrastructures with intermediate pontics on 2 regular-length Morse taper implants (4x11?mm). The simulations of the groups were created with Ansys Workbench 10.0 software. The results revealed that the RPG presented greater areas of possible fragility due to higher stress concentrations, for example, in the cervical area of the union between the implant and component the top platform of the abutment, as well as greater coverage of the stress by the cervical implant threads. The RPG infrastructure was also more affected by stresses in the connection areas between the prostheses and on the occlusal surface. There is an advantage to using prostheses supported by a greater number of implants (RCG) because this decreases the stress in the analyzed structures and consequently improves stress dissipation to the supporting bone, which would preserve the system.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号