Manufacturing-induced disulfide reduction has recently been reported for monoclonal human immunoglobulin gamma (IgG) antibodies, a widely used modality in the biopharmaceutical industry. This effect has been tied to components of the intracellular thioredoxin reduction system that are released upon cell breakage. Here, we describe the effect of process parameters and intrinsic molecule properties on the extent of reduction. Material taken from cell cultures at the end of production displayed large variations in the extent of antibody reduction between different products, including no reduction, when subjected to the same reduction-promoting harvest conditions. Additionally, in a reconstituted model in which process variables could be isolated from product properties, we found that antibody reduction was dependent on the cell line (clone) and cell culture process. A bench-scale model using a thioredoxin/thioredoxin reductase regeneration system revealed that reduction susceptibility depended on not only antibody class but also light chain type; the model further demonstrates that the trend in reducibility was identical to DTT reduction sensitivity following the order IgG1λ > IgG1κ > IgG2λ > IgG2κ. Thus, both product attributes and process parameters contribute to the extent of antibody reduction during production.  相似文献   
2.
Therapeutic proteins circulating in blood are in a highly crowded, redox environment at high temperatures of ~37°C. These molecules circulate in the presence of enzymes and other serum proteins making it difficult to predict from in vitro studies the stability, aggregation or pharmacokinetics of a therapeutic protein in vivo. Here, we describe use of a high throughput capillary electrophoresis based microfluidic device (LabChip GXII) to obtain pharmacokinetics (PK) of a fluorescently labeled human mAb directly from serum. The non-labeled and labeled mAbs were evaluated in single dose rat PK studies using a traditional ELISA method or LabChip GXII, respectively. The fluorescent dye did not significantly alter clearance of this particular mAb, and PK parameters were comparable for labeled and unlabeled molecules. Further, from the CE profile we concluded that the mAb was resistant to fragmentation or aggregation during circulation. In a follow-up experiment, dimers were generated from the mAb using photo-induced cross-linking of unmodified proteins (PICUP) and labeled with the same fluorophore. The extent of dimerization was incomplete and some monomer and higher molecular weight species were found in the preparation. In rat PK studies, the serum concentration-time profile of the three entities present in the dimer preparation could be followed simultaneously with the GXII technology. While further studies are warranted, we believe this method could be adapted to obtain PK of different forms of antibodies (oxidized, deamidated or various glycosylated species) and other proteins.  相似文献   
3.
Signal peptides used in biosynthesis of proteins are cleaved at a very specific site by signal peptidase during posttranslational translocation of cytoplasmic proteins across the membrane. In some cases, however, there can be cleavage at nonspecific sites, giving rise to heterogeneity in the mature protein, which manifests itself as either elongation or truncation of the N terminus of the mature protein. When used as biopharmaceutical therapeutics, such heterogeneities may be a cause for concern, depending on the nature of the heterogeneity. This article describes the determination of such heterogeneity by peptide mapping in both the heavy chain and the light chain (LC) of a Chinese hamster ovary (CHO) cell-expressed monoclonal antibody (mAb). The peptide map method described here was capable of detecting the extended N-terminal peptides at levels as low as 1% relative to the peak area of the intact N-terminal peptide. The LC of a mAb product was truncated at its N termini by two amino acid residues at approximately 3-4% levels, resulting from alternate signal peptide cleavage. This article describes the quantitation of this truncation by liquid chromatography-mass spectrometry (LC-MS) peptide mapping. Also described is analysis and characterization of LC truncation by reduced and denatured capillary electrophoresis in sodium dodecyl sulfate (CE-SDS). The truncated mAb, which was devoid of the two N-terminal amino acids, was engineered and shown to migrate as the “pre-LC” peak in reduced CE-SDS assay. The amount of the pre-LC peak recovered from the CE-SDS assay was shown to correlate with the amount of truncated peptide observed from the reduced and alkylated peptide map of the engineered mAb.  相似文献   
4.
《MABS-AUSTIN》2013,5(6):1113-1121
ABSTRACT

Charge variants are important attributes of monoclonal antibodies, including antibody-drug conjugates (ADCs), because charge variants can potentially influence the stability and biological activity of these molecules. Ion exchange chromatography (IEX) is widely used for charge variants analysis of mAbs and offers the feasibility of fractionation for in-depth characterization. However, the conjugated linker-drug on ADCs could potentially affect the separation performance of IEX, considering IEX separation relies on surface charge distribution of analyte and involves the interaction between analyte surface and IEX stationary phase. Here, we investigated weak cation exchange chromatography (WCX) for its application in analyzing three ADCs (two broad distribution ADCs and an ADC with controlled conjugation sites) and the 2-drug/4-drug loaded species isolated from the two broad distribution ADCs using hydrophobic interaction chromatography. The major peaks in WCX profile were characterized via fraction collection followed by capillary electrophoresis-sodium dodecyl sulfate or peptide mapping. Results suggested that both the number of drug loads and conjugation sites could impact WCX separation of an ADC. The hypothesis was that the linker drugs could interfere with the ionic interaction between its surrounding amino acids on the mAb surface and column resin, which reduced the retention of ADCs on WCX column in this study. Our results further revealed that WCX brings good selectivity towards positional isomers, but limited resolution for different drug load, which causes the peak compositions of the two broad-distribution ADCs to be highly complex. We also compared results from WCX and imaged capillary isoelectric focusing (icIEF). Results showed that separation in icIEF was less influenced by conjugated linker drugs for the ADCs studied in this work, and better alignment was found between the two techniques for the ADC with controlled conjugate sites. Overall, this work provides insights into the complexity of WCX analysis of ADCs, which should be considered during method development and sample characterization.  相似文献   
5.
目的:测定抗CD52人源单克隆抗体参比品单体纯度及非糖基化重链比例。方法:采用PA800 plus毛细管电泳系统,非还原十二烷基苯硫酸钠-毛细管电泳(CE-SDS)测定抗CD52人源单克隆抗体单体纯度,以及用还原CE-SDS电泳测定非糖化重链比例。结果:非还原CE-SDS三次测定单体纯度平均值为93.57%,主峰的迁移时间及修正峰面积百分比RSD分别为0.16%和0.19%;还原CE-SDS电泳重链修正峰面积百分比平均值为66.89%,修正峰面积百分比及迁移时间RSD分别为0.09%和0%;轻链修正峰面积百分比平均值为32.30%;轻链修正峰面积及迁移时间RSD分别为0%和0%;非糖基化重链修正峰面积百分比平均值为0.87%,修正峰面积百分比及迁移时间RSD分别为6.66%和0.27%。结论:CE-SDS测定抗CD52人源单抗单体纯度及非糖化重链比例实验结果偏差较小,表明结果准确可靠。  相似文献   
6.
Quality by Design (QbD) principles play an increasingly important role in the pharmaceutical industry. Here, we used an analytical QbD (AQbD) approach to develop a capillary electrophoresis sodium dodecyl sulfate under reducing conditions (rCE-SDS), with the aim of replacing SDS-polyacrylamide gel electrophoresis (SDS-PAGE) as release and stability test method for a commercialized monoclonal antibody product. Method development started with defining analytical method performance requirements as part of an analytical target profile, followed by a systematic risk assessment of method input parameters and their relation to defined method outputs. Based on this, design of experiments studies were performed to identify a method operable design region (MODR). The MODR could be leveraged to improve method robustness. In a bridging study, it was demonstrated that the rCE-SDS method is more sensitive than the legacy SDS-PAGE method, and a conversion factor could be established to compensate for an off-set due to the higher sensitivity, without losing the correlation to the historical data acquired with the former method. Overall, systematic application of analytical Quality by Design principles for designing and developing a new analytical method helped to elucidate the complex dependency of method outputs on its input parameters. The link of the method to product quality attributes and the definition of method performance requirements were found to be most relevant for derisking the analytical method switch, regarding impact on the control strategy.  相似文献   
7.
《MABS-AUSTIN》2013,5(4):521-531
Therapeutic proteins circulating in blood are in a highly crowded, redox environment at high temperatures of ~37°C. These molecules circulate in the presence of enzymes and other serum proteins making it difficult to predict from in vitro studies the stability, aggregation or pharmacokinetics of a therapeutic protein in vivo. Here, we describe use of a high throughput capillary electrophoresis based microfluidic device (LabChip GXII) to obtain pharmacokinetics (PK) of a fluorescently labeled human mAb directly from serum. The non-labeled and labeled mAbs were evaluated in single dose rat PK studies using a traditional ELISA method or LabChip GXII, respectively. The fluorescent dye did not significantly alter clearance of this particular mAb, and PK parameters were comparable for labeled and unlabeled molecules. Further, from the CE profile we concluded that the mAb was resistant to fragmentation or aggregation during circulation. In a follow-up experiment, dimers were generated from the mAb using photo-induced cross-linking of unmodified proteins (PICUP) and labeled with the same fluorophore. The extent of dimerization was incomplete and some monomer and higher molecular weight species were found in the preparation. In rat PK studies, the serum concentration-time profile of the three entities present in the dimer preparation could be followed simultaneously with the GXII technology. While further studies are warranted, we believe this method could be adapted to obtain PK of different forms of antibodies (oxidized, deamidated or various glycosylated species) and other proteins.  相似文献   