首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   13篇
  免费   0篇
  2021年   1篇
  2017年   2篇
  2016年   2篇
  2015年   1篇
  2014年   1篇
  2013年   2篇
  2011年   1篇
  2010年   1篇
  2007年   1篇
  2002年   1篇
排序方式: 共有13条查询结果,搜索用时 31 毫秒
1.
2.

Background

Implantable cardioverter-defibrillators (ICDs) are widely used for the prevention of sudden cardiac death. At present, both clinical benefit and cost-effectiveness of ICD therapy in primary prevention patients are topics of discussion, as only a minority of these patients will eventually receive appropriate ICD therapy.

Methods/design

The DO-IT Registry is a nationwide prospective cohort with a target enrolment of 1,500 primary prevention ICD patients with reduced left ventricular function in a setting of structural heart disease. The primary outcome measures are death and appropriate ICD therapy for ventricular tachyarrhythmias. Secondary outcome measures are inappropriate ICD therapy, death of any cause, hospitalisation for ICD related complications and for cardiovascular reasons. As of December 2016, data on demographic, clinical, and ICD characteristics of 1,468 patients have been collected. Follow-up will continue up to 24 months after inclusion of the last patient. During follow-up, clinical and ICD data are collected based on the normal follow-up of these patients, assuming ICD interrogations take place every six months and clinical follow-up is once a year. At baseline, the mean age was 66 (standard deviation [SD] 10) years and 27% were women.

Conclusion

The DO-IT Registry represents a real-world nationwide cohort of patients receiving ICDs for primary prevention of sudden cardiac death with reduced left ventricular function in a setting of structural heart disease. The registry investigates the efficacy of the current practice and aims to develop prediction rules to identify subgroups who will not (sufficiently) benefit from ICD implantation and to provide results regarding costs and budget impact of targeted supply of primary preventions ICDs.
  相似文献   
3.

Background

The number of cardiac rhythm device implantations has been growing fast due to expanding indications and ageing of the population. Complications of implantation were rare in the trials. However, these involved small numbers and selected patients. Prospective real-life data are necessary to assess cardiac device implantation procedure-related risks.

Objective

To determine the incidence and predictors of lead-related re-intervention in a Dutch high-volume teaching hospital.

Methods

Data from all patients who underwent cardiac rhythm device implantation between January 2010 and December 2011 were collected in a prospective registry. At least 1 year of follow-up regarding re-intervention was available for all patients. Lead-related reasons for re-intervention were categorised into lead dislodgement, malfunctioning or perforation.

Results

One thousand nine hundred twenty-nine devices including 3909 leads were implanted. In 595 patients (30.8 %) a CRT-D/P was implanted. Lead-related re-intervention was necessary in 86 (4.4 %) patients; it was more common in younger and male patients, and due to either lead dislodgement (66 %), malfunctioning (20 %) or perforation (18 %). Coronary sinus lead dislodgement or malfunctioning was 1.4 %. Right atrial dislodgement (1.9 %, p < 0.001) or ICD lead dislodgement (1.8 %, p = 0.002) was more common than right ventricular dislodgement (0.3 %). The incidence of lead malfunctioning was higher (0.8 %) in ICD leads. An apical position of the right ventricular lead and lateral wall position of the right atrial lead were related to cardiac perforation.

Conclusions

The incidence of lead-related re-intervention was comparable with the literature. The majority of re-interventions were due to lead dislodgements, particularly with right atrial and ICD leads. Re-intervention due to coronary sinus lead dislodgement was rare.  相似文献   
4.
Many important differences in the presentation and clinical course of cardiac arrhythmias are present between men and women that should be accounted for in clinical practice. In this paper, we review published data on gender differences in cardiac excitable properties, supraventricular tachycardias, ventricular tachycardias, sudden cardiac death, and the utilisation of implantable defibrillators and cardiac resynchronisation therapy. Women have a higher heart rate at rest, and a longer QT interval than men. They further have a narrower QRS complex and lower QRS voltages on the 12-lead ECG with more often non-specific repolarisation abnormalities at rest. Supraventricular tachycardias, such as AV nodal reentrant tachycardia, are twice as frequent in women compared with men. Atrial fibrillation, however, has a 1.5-fold higher prevalence in men. The triggers for idiopathic right ventricular outflow tract tachycardia (VT) initiation are gender specific, i.e. hormonal changes play an important role in the occurrence of these VTs in women. There are clear-cut gender differences in acquired and congenital LQTS. Brugada syndrome affects men more commonly and severely than women. Sudden cardiac death is less prevalent in women at all ages and occurs 10 years later in women than in men. This may be related to the later onset of clinically manifest coronary heart disease in women. Among patients who receive ICDs and CRT devices, women appear to be under-represented, while they may benefit even more from these novel therapies.  相似文献   
5.
To prevent deterioration of left ventricular function during right ventricular apical pacing, permanent direct His bundle stimulation can be considered in selected patients with low left ventricular ejection fraction and a normal His-ventricle conduction time. We describe our first short-term experiences with permanent direct His bundle pacing in three patients. In two patients His bundle stimulation was still effective at six weeks'' follow-up. In one patient loss of capture was registered, after which conventional RV apical pacing was performed.  相似文献   
6.
Background. The Medtronic Sprint Fidelis ICD lead is prone to failure and the rate of failure seems to be increasing. The aim of this study was to investigate the rate of Sprint Fidelis lead failure, the characteristics, the mode of presentation and possible predictors of lead failure.Methods and Results. The rate, characteristics and presentation of Sprint Fidelis lead failure was assessed in this single-centre survey. 619 Sprint Fidelis ICD leads were implanted at our centre between December 2004 and August 2007. The mean follow-up was 32±10 (range 22–60) months; 35 patients (5.7%) required a lead re-implantation because of failure of the pace-sense conductor. Mean duration of lead survival was 23±12 (2–46) months and the rate of failure did not stabilise during follow-up. The mode of presentation was inappropriate shocks in 16 patients (45.7%), alarm alert in 12 patients (34.3%), and detection at routine follow-up in seven patients (20%). In 31 patients (89%), interrogation data revealed a sudden rise in impedance and/or frequent short VV intervals prior to lead failure and in five patients an isolated decrease of R wave (<2.5 mV). The interrogation data were not different from patients with shocks compared with patients without shocks. The interrogation data at routine follow-up in the first three months after implant were normal and stable.Conclusion. The rate of Sprint Fidelis lead failure reaches 5.7% at a mean follow-up duration of 32 months. The rate of failure does not seem to stabilise. Routine follow-up can not predict lead failure or prevent inappropriate shocks. (Neth Heart J 2010;18:12-7.)  相似文献   
7.
8.
Brugada syndrome is an inherited cardiac disease and is associated with a peculiar pattern on the electrocardiogram and an increased risk of sudden death. Electrical storm is a malignant but rare phenomenon in symptomatic patients with Brugada syndrome. We describe a patient who presented with repetitive ICD discharges during two episodes of recurrent VF. After the initiation of isoproterenol infusion and oral quinidine, the ventricular tachyarrhythmias were successfully suppressed. (Neth Heart J 2007;15:151-4.)  相似文献   
9.

Background

Super-responders to cardiac resynchronisation therapy (CRT) show an exceptional improvement in left ventricular ejection fraction (LVEF). Previous studies showed that apical rocking was independently associated with echocardiographic response to CRT. However, little is known about the association between apical rocking and super-response to CRT.

Objectives

To determine the independent association of LV apical rocking with super-response to CRT in a large cohort.

Methods

A cohort of 297 consecutive heart failure patients treated with primary indication for CRT-D were included in an observational registry. Apical rocking was defined as motion of the left ventricular (LV) apical myocardium perpendicular to the LV long axis. ‘Super-response’ was defined by the top quartile of LVEF response based on change from baseline to follow-up echocardiogram. Best-subset regression analysis identified predictors of LVEF super-response to CRT.

Results

Apical rocking was present in 45 % of patients. Super-responders had an absolute mean LVEF increase of 27 % (LVEF 22.0 % ± 5.7 at baseline and 49.0 % ± 7.5 at follow-up). Apical rocking was significantly more common in super-responders compared with non-super-responders (76 and 34 %, P < 0.001). In univariate analysis, female gender (OR 2.39, 95 % CI 1.38–4.11), lower LVEF at baseline (OR 0.91 95 % CI 0.87–0.95), non-ischaemic aetiology (OR 4.15, 95 % CI 2.33–7.39) and apical rocking (OR 6.19, 95 % CI 3.40–11.25) were associated with super-response. In multivariate analysis, apical rocking was still strongly associated with super-response (OR 5.82, 95 % CI 2.68–12.61). Super-responders showed an excellent clinical prognosis with a very low incidence of heart failure admission, cardiac mortality and appropriate ICD therapy.

Conclusion

Apical rocking is independently associated with super-response to CRT.

Electronic supplementary material

The online version of this article (doi:10.1007/s12471-015-0768-4) contains supplementary material, which is available to authorized users.  相似文献   
10.

Aims

To determine the frequency, characteristics and risk factors of cardiac device infections in the Isala Hospital.

Methods

We retrospectively studied all patients who underwent cardiac device procedures performed in the cardiac catheterisation lab and the operating room from 2010 to 2012. All patients who developed a cardiac device infection were reviewed for its characteristics.

Results

31/2026 patients developed a cardiac device infection (1.5 %). One (3.2 %) patient died within 30 days of hospitalisation. Device infection rates for procedures in the catheterisation lab and operating room were similar (p = 0.60). Positive cultures were present in 27/31 (87 %) cases. These consisted predominantly of micro-organisms that are part of the skin flora (84 %). The mean time between device procedure and infection was 14 ± 21 months (range 0–79). Cardiac device infection was significantly associated with device revision, (65 % were revisions in patients with device infection vs. 30 % revisions in patients without device infection, p = 0.011) and placement of a left ventricular lead in pacemaker implantations (59 % of patients with vs. 51 % of patients without device infection, p < 0.001).

Conclusion

The frequency of cardiac device infection was 1.5 % with a mortality of 3.2 % within 30 days, which is lower compared with other registries. Cardiac device infections were associated with device revisions and placement of left ventricular leads in pacemaker implantations.  相似文献   