全文获取类型
收费全文 | 74篇 |
免费 | 4篇 |
出版年
2022年 | 1篇 |
2021年 | 2篇 |
2019年 | 1篇 |
2016年 | 2篇 |
2015年 | 2篇 |
2013年 | 4篇 |
2012年 | 2篇 |
2011年 | 1篇 |
2008年 | 2篇 |
2007年 | 1篇 |
2006年 | 3篇 |
2005年 | 1篇 |
2002年 | 1篇 |
2001年 | 1篇 |
1999年 | 2篇 |
1995年 | 1篇 |
1992年 | 2篇 |
1990年 | 3篇 |
1989年 | 2篇 |
1988年 | 1篇 |
1986年 | 4篇 |
1985年 | 2篇 |
1984年 | 2篇 |
1983年 | 4篇 |
1982年 | 3篇 |
1981年 | 1篇 |
1978年 | 2篇 |
1977年 | 1篇 |
1975年 | 5篇 |
1974年 | 2篇 |
1973年 | 7篇 |
1972年 | 5篇 |
1971年 | 1篇 |
1969年 | 1篇 |
1968年 | 1篇 |
1967年 | 2篇 |
排序方式: 共有78条查询结果,搜索用时 46 毫秒
1.
2.
Carmen V. Voogt Emmanuel Kuntsche Marloes Kleinjan Evelien A. P. Poelen Lex A. C. J. Lemmers Rutger C. M. E. Engels 《PloS one》2013,8(11)
Background
Alcohol consumption of college students has a fluctuating nature, which might impact the measurement of intervention effects. By using 25 follow-up time-points, this study tested whether intervention effects are robust or might vary over time.Methods
Data were used from a two-arm parallel group randomized controlled trial applying ecological momentary assessment (EMA) with 30 data time-points in total. Students between 18 and 24 years old who reported heavy drinking in the past six months and who were ready to change their alcohol consumption were randomly assigned to the experimental (n = 456: web-based brief alcohol intervention) and control condition (n = 451: no intervention). Outcome measures were weekly alcohol consumption, frequency of binge drinking, and heavy drinking status.Results
According to the intention-to-treat principle, regression analyses revealed that intervention effects on alcohol consumption varied when exploring multiple follow-up time-points. Intervention effects were found for a) weekly alcohol consumption at 1, 2, 3, 4, and 7 weeks follow-up, b) frequency of binge drinking at 1, 2, 7, and 12 weeks follow-up, and c) heavy drinking status at 1, 2, 7, and 16 weeks follow-up.Conclusions
This research showed that the commonly used one and six month follow-up time-points are relatively arbitrary and not using EMA might bring forth erroneous conclusions on the effectiveness of interventions. Therefore, future trials in alcohol prevention research and beyond are encouraged to apply EMA when assessing outcome measures and intervention effectiveness.Trial registration
Netherlands Trial Register NTR2665 相似文献3.
The Impact of Adult Vitamin D Deficiency on Behaviour and Brain Function in Male Sprague-Dawley Rats
Jacqueline H. Byrne Meggie Voogt Karly M. Turner Darryl W. Eyles John J. McGrath Thomas H. J. Burne 《PloS one》2013,8(8)
Background
Vitamin D deficiency is common in the adult population, and this has been linked to depression and cognitive outcomes in clinical populations. The aim of this study was to investigate the effects of adult vitamin D (AVD) deficiency on behavioural tasks of relevance to neuropsychiatric disorders in male Sprague-Dawley rats.Methods
Ten-week old male Sprague-Dawley rats were fed a control or vitamin D deficient diet for 6 weeks prior to, and during behavioural testing. We first examined a range of behavioural domains including locomotion, exploration, anxiety, social behaviour, learned helplessness, sensorimotor gating, and nociception. We then assessed locomotor response to the psychomimetic drugs, amphetamine and MK-801. Attention and vigilance were assessed using the 5 choice serial reaction time task (5C-SRT) and the 5 choice continuous performance task (5C-CPT) and, in a separate cohort, working memory was assessed using the delay match to sample (DMTS) task. We also examined excitatory and inhibitory neurotransmitters in prefrontal cortex and striatum.Results
AVD-deficient rats were deficient in vitamin D3 (<10 nM) and had normal calcium and phosphate levels after 8–10 weeks on the diet. Overall, AVD deficiency was not associated with an altered phenotype across the range of behavioural domains tested. On the 5C-SRT AVD-deficient rats made more premature responses and more head entries during longer inter-trial intervals (ITI) than control rats. On the 5C-CPT AVD-deficient rats took longer to make false alarm (FA) responses than control rats. AVD-deficient rats had increases in baseline GABA levels and the ratio of DOPAC/HVA within the striatum.Conclusions
AVD-deficient rats exhibited no major impairments in any of the behavioural domains tested. Impairments in premature responses in AVD-deficient rats may indicate that these animals have specific alterations in striatal systems governing compulsive or reward-seeking behaviour. 相似文献4.
Pacemaker syndrome represents the clinical consequences of the haemodynamic adverse effects of atrioventricular asynchrony during pacing. Patients suffering from hypertrophic cardiomyopathy may be particularly sensitive to these effects because of the importance of atrial systolic contribution to left ventricular diastolic filling. In this case report, we describe the symptoms and cause of pacemaker syndrome in a patient with hypertrophic obstructive cardiomyopathy. 相似文献
5.
Monitoring and control of production processes for biopharmaceuticals have become standard requirements to support consistency and quality. In this paper, a constant specific growth rate in fed-batch cultivation of Bordetella pertussis is achieved by a newly designed specific growth rate controller. The performance of standard control methods is limited because of the time-varying characteristics due to the exponentially increasing biomass and volume. To cope with the changing dynamics, a stable model reference adaptive controller is designed which adapts the controller settings as volume and biomass increase. An important asset of the design is that dissolved oxygen is the only required online measurement. An original design without considering the dissolved oxygen dynamics resulted experimentally in oscillatory behaviour. Hence, in contrast to common believes, it is essential to include dissolved oxygen dynamics. The robustness of this novel design was tested in simulation. The validity of the design was confirmed by laboratory experiments for small-scale production of B. pertussis. The controller was able to regulate the specific growth rate at the desired set point, even during a long fed-batch cultivation time with exponentially increasing demands for substrates and oxygen. 相似文献
6.
7.
de Cock CC Elders J van Hemel NM van den Broek K van Erven L de Mol B Talmon J Theuns DA de Voogt W 《Netherlands heart journal》2012,20(2):53-65
Remote monitoring of cardiac implanted electronic devices (CIED: pacemaker, cardiac resynchronisation therapy device and implantable cardioverter defibrillator) has been developed for technical control and follow-up using transtelephonic data transmission. In addition, automatic or patient-triggered alerts are sent to the cardiologist or allied professional who can respond if necessary with various interventions. The advantage of remote monitoring appears obvious in impending CIED failures and suspected symptoms but is less likely in routine follow-up of CIED. For this follow-up the indications, quality of care, cost-effectiveneness and patient satisfaction have to be determined before remote CIED monitoring can be applied in daily practice. Nevertheless remote CIED monitoring is expanding rapidly in the Netherlands without professional agreements about methodology, responsibilities of all the parties involved and that of the device patient, and reimbursement. The purpose of this consensus document on remote CIED monitoring and follow-up is to lay the base for a nationwide, uniform implementation in the Netherlands. This report describes the technical communication, current indications, benefits and limitations of remote CIED monitoring and follow-up, the role of the patient and device manufacturer, and costs and reimbursement. The view of cardiology experts and of other disciplines in conjunction with literature was incorporated in a preliminary series of recommendations. In addition, an overview of the questions related to remote CIED monitoring that need to be answered is given. This consensus document can be used for future guidelines for the Dutch profession. 相似文献
8.
Background. Correct pacemaker (PM) diagnosis of paroxysmal atrial tachyarrhythmias is crucial for their prevention and intervention with specific atrial pacing programmes. The PM mode switch to only ventricular pacing after detection of atrial tachyarrhythmias is often used as the parameter to quantify the ‘burden’ of atrial tachyarrhythmias. Objectives. This review addresses potential errors in the detection and diagnosis of atrial tachyarrhythmias, sometimes resulting in incorrect mode switches. The interpretation of PM-stored data of patients with atrial tachyarrhythmias and the results of trials of pace prevention and intervention can be better appreciated with more insight into the technical options and pitfalls. Results. Literature and clinical experience demonstrate that the correctness of PM-derived diagnosis of atrial tachyarrhythmias depends on 1) the sensitivity setting to detect the onset and perpetuation of atrial tachyarrhythmias frequently characterised by variable and low-voltage signals, 2) the rejection of far-field R wave sensing by the atrial sense amplifier, 3) the facility for verification of mode switches by a high-quality intracardiac registration of the nonmodified atrial electrogram. The configuration of the atrial lead also contributes to the diagnostic performance of the PM. Conclusion. Not only pacing algorithms and diverse technical PM features but also the atrial lead configuration are currently the limiting factors to the fully reliable, automated detection and diagnosis of atrial tachyarrhythmias. If these technical shortcomings can be improved, better signal processing will result. Then atrial pacing to prevent or suppress atrial tachyarrhythmias will be more justified. (Neth Heart J 2008;16:201-10.) 相似文献
9.
An 84-year-old female patient presented to the coronary care unit with dizziness. A DDD-R minute ventilation sensor pacemaker had been implanted eight years previously. The ECG showed an atrial and ventricular paced rhythm of 140 beats/min. After disconnecting the patient from the cardiac monitor the pacemaker rate dropped gradually to 90 beats/min. The cardiac rhythm monitoring system applies low-amplitude electrical pulses in order to measure respiration rate by transthoracic impedance (TTI) measurement. The minute ventilation pacemaker sensor is driven by the same TTI measurement for rate response. Inappropriate interference between these two systems caused a sensor-driven high pacemaker rate. The dizziness was not related to the sensor-driven high rate. 相似文献
10.