首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   20篇
  免费   0篇
  2022年   1篇
  2020年   1篇
  2018年   1篇
  2017年   1篇
  2015年   1篇
  2014年   3篇
  2013年   4篇
  2012年   3篇
  2011年   1篇
  2010年   1篇
  2007年   1篇
  2004年   1篇
  2002年   1篇
排序方式: 共有20条查询结果,搜索用时 15 毫秒
1.
This paper describes the development of a computational model to calculate wear rates in total shoulder prostheses, for a 5–150 degrees arm abduction. Anatomical keeled and pegged prosthesis as well as reversed prosthesis were the studied implants. The bone models were built based on computed tomography (CT) images and using a computer aided design-based modelling pipeline. The finite element method was used to solve the contact problem between the surface of the polyethylene (PE) components and the corresponding articular component. The aim of this work was to determine linear and volumetric PE wear, for several radial mismatches, in conditions of pathological (rheumatoid arthritis) and non-pathological bone. Results showed that contact pressures and linear wear developed in anatomical prosthesis were higher than those visualised in reversed prosthesis. However, anatomical prosthesis exhibited a better volumetric wear performance. Moreover, our findings indicated higher values of volumetric wear in higher congruent models and on pathological bone conditions.  相似文献   
2.
The response of bovine bone to the presence of an implant is analysed with the aim of simulating bone remodelling in a developing model of a polymeric intramedullary interlocking nail for veterinary use. A 3-D finite element model of the femur diaphysis is built based on computed tomography images and using a CAD-based modelling pipeline. The bone remodelling process after the surgery is analysed and compared with the healthy bone. The remodelling law assumes that bone adapts to the mechanical environment. For the analyses a consistent set of loads is determined for the bovine walk cycle. The remodelling results reproduce the morphologic features of bone and provide evidence of the difference on the bone behaviour when comparing metallic and polymeric nails. Our findings indicate that an intramedullary polymeric nail has the advantage over the metallic one of improving long-term bone healing and possibly avoiding the need of the implant removal.  相似文献   
3.
This paper describes the development of a computational model to calculate wear rates in total shoulder prostheses, for a 5-150 degrees arm abduction. Anatomical keeled and pegged prosthesis as well as reversed prosthesis were the studied implants. The bone models were built based on computed tomography (CT) images and using a computer aided design-based modelling pipeline. The finite element method was used to solve the contact problem between the surface of the polyethylene (PE) components and the corresponding articular component. The aim of this work was to determine linear and volumetric PE wear, for several radial mismatches, in conditions of pathological (rheumatoid arthritis) and non-pathological bone. Results showed that contact pressures and linear wear developed in anatomical prosthesis were higher than those visualised in reversed prosthesis. However, anatomical prosthesis exhibited a better volumetric wear performance. Moreover, our findings indicated higher values of volumetric wear in higher congruent models and on pathological bone conditions.  相似文献   
4.
This paper presents a biomechanical analysis of the cervical C5-C6 functional spine unit before and after the anterior cervical discectomy and fusion. The aim of this work is to study the influence of the medical procedure and its instrumentation on range of motion and stress distribution. First, a three-dimensional finite element model of the lower cervical spine is obtained from computed tomography images using a pipeline of image processing, geometric modelling and mesh generation software. Then, a finite element study of parameters' influence on motion and a stress analysis at physiological and different post-operative scenarios were made for the basic movements of the cervical spine. It was confirmed that the results were very sensitive to intervertebral disc properties. The insertion of an anterior cervical plate influenced the stress distribution at the vertebral level as well as in the bone graft. Additionally, stress values in the graft decreased when it is used together with a cage.  相似文献   
5.
The anterior cervical fusion is an established surgical procedure for spine stabilization after the removal of an intervertebral disc. However, it is not yet clear which bone graft represents the best choice and whether surgical devices can be efficient and beneficial for fusion. The aim of this work is to study the influence of the spine instrumentation on bone remodeling after a cervical spine surgery and, consequently, on the fusion process. A finite element model of the cervical spine was developed, having computed tomography images as input. Bone was modeled as a porous material characterized by the relative density at each point and the bone remodeling law was derived assuming that bone self-adapts in order to achieve the stiffest structure for the supported loads, with the total bone mass regulated by the metabolic cost of maintaining bone tissue. Apart from the analysis of healthy cervical spine, different surgical scenarios were tested: bone graft with or without a cage and the use of a stabilization plate system. Results showed that the anterior and posterior regions of the disc space are more important to stress transmission and that spinal devices reduce bone growth within bone grafts, being plate systems the most interfering elements. The material of the interbody cages plays a major role in fusion and, therefore, it should be carefully chosen.  相似文献   
6.
This study aimed to quantify the time-motion demands and intra-team movement synchronization during the pre-season matches of a professional soccer team according to the opposition level. Positional data from 20 players were captured during the first half of six pre-season matches of a Portuguese first league team. Time-motion demands were measured by the total distance covered and distance covered at different speed categories. Intra-team coordination was measured by calculating the relative phase of all pairs of outfield players. Afterwards, the percentage of time spent in the −30° to 30° bin (near-in-phase mode of coordination) was calculated for each dyad as a measure of space-time movement synchronization. Movement synchronization data were analyzed for the whole team, according to each dyad average speed and by groups of similar dyadic synchronization tendencies. Then, these data were compared according to the opponent team level (first league; second league; amateurs). Time-motion demands showed no differences in total distance covered per opposition levels, while matches opposing teams of superior level revealed more distance covered at very high intensity. Competing against superior level teams implied more time in synchronized behavior for the overall displacements and displacements at higher intensities. These findings suggest that playing against higher-level opponents (1st league teams) increased time-motion demands at high intensities in tandem with intra-team movement synchronization tendencies.  相似文献   
7.
This paper presents a computational simulator for the hip to compute the wear and heat generation on artificial joints. The friction produced on artificial hip joints originates wear rates that can lead to failure of the implant. Furthermore, the frictional heating can increase the wear. The developed computational model calculates the wear in the joint and the temperature in the surrounding zone, allowing the use of different combinations of joint materials, daily activities and different individuals. The pressure distribution on the joint bearing surfaces is obtained with the solution of a contact model. The heat generation by friction and the volumetric wear is computed from the pressure distribution and the sliding distance. The temperature is obtained from the solution of a transient heat conduction problem that includes the time-dependent heat generated by friction. The contact and heat conduction problems are solved numerically with the Finite Element Method. The developed computational model performs a full simulation of the acetabular bearing surface behaviour, which is useful for acetabular cup design and material selection. The results obtained by the present model agree with experimental and clinical data, as well as other numerical studies.  相似文献   
8.
9.
Apple (Malus × domestica) is an economically important temperate fruit-bearing crop which belongs to the family of Rosaceae and its pomaceous fruit is one of the most commonly cultivated. Several studies have demonstrated that the cell wall plays a pivotal role during flower and fruit development. It takes active part in pollen tube growth and contributes to determine the fruit firmness trait through the action of cell wall-related enzymes (i.e. polygalacturonase and pectinmethylesterase). We have investigated the expression of callose and cellulose synthase genes during flowering from tight cluster to anthesis and during early fruit development in domesticated apple. We also link the changes observed in gene expression to the profile of soluble non-structural carbohydrates at different developmental stages of flowers/fruitlets and to the qualitative results linked to wall polysaccharides’ composition obtained through near-infrared spectroscopy. This work represents an important addition to the study of tree physiology with respect to the analysis of the expression of callose and cellulose synthase genes during flower and early fruit development in domesticated apple.  相似文献   
10.
The primary stem stability is an essential factor for success of cementless hip stems. A correct choice of the stem geometry can improve the stem stability and, consequently, increase the life time of a hip implant. In this work, it is proposed a computational model for shape optimization of cementless hip stems. The optimization problem is formulated by the minimization of relative displacement and stress on bone/stem interface using a multi-criteria objective function. Also multiple loads are considered to incorporate several daily life activities. Design variables are parameters that characterize the geometry of selected cross sections, which are subject to geometric constraints to ensure a clinically admissible shape. The stem/bone set is considered a structure in equilibrium with contact conditions on interface. The contact formulation allows us to analyze different lengths of porous coating. The optimization problem is solved numerically by a steepest descent method. The interface stress and relative displacement are obtained solving the contact problem by the finite element method. Numerical examples are presented for a two-dimensional model of a hip stem, however, the formulation is general and can be applied to the three-dimensional case. The model gives indications about the relation between shape, porous coating and prosthesis stability.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号