全文获取类型
收费全文 | 115篇 |
免费 | 2篇 |
出版年
2021年 | 1篇 |
2019年 | 1篇 |
2017年 | 2篇 |
2016年 | 4篇 |
2015年 | 1篇 |
2014年 | 3篇 |
2013年 | 8篇 |
2012年 | 7篇 |
2011年 | 6篇 |
2010年 | 4篇 |
2009年 | 3篇 |
2008年 | 8篇 |
2007年 | 4篇 |
2006年 | 6篇 |
2005年 | 7篇 |
2004年 | 2篇 |
2003年 | 5篇 |
2002年 | 3篇 |
2001年 | 1篇 |
2000年 | 4篇 |
1999年 | 4篇 |
1998年 | 4篇 |
1997年 | 1篇 |
1996年 | 1篇 |
1995年 | 4篇 |
1994年 | 1篇 |
1993年 | 1篇 |
1992年 | 2篇 |
1991年 | 5篇 |
1990年 | 4篇 |
1989年 | 2篇 |
1988年 | 1篇 |
1987年 | 2篇 |
1986年 | 1篇 |
1985年 | 1篇 |
1984年 | 1篇 |
1981年 | 1篇 |
1974年 | 1篇 |
排序方式: 共有117条查询结果,搜索用时 62 毫秒
1.
2.
Analysis by 1H-NMR spectroscopic techniques of the conformation of the N-terminal segment of the LC1 alkali light chain of rabbit skeletal muscle has shown that this portion of the molecule adopts a well-defined elongated configuration. This rod-like feature is a consequence of the Ala/Pro-rich composition and the functional aspects of such conformational preference in this and similar segments in other proteins are discussed. 相似文献
3.
4.
We have shown previously that dystrophin is a component of postsynaptic membranes in Torpedo electric organ and is localized at mammalian neuromuscular synapses. In skeletal muscle, dystrophin is also detectable at the non-synaptic membrane of the myofiber, whereas in the electric organ, dystrophin is strictly localized to the postsynaptic membrane, and is not detectable in non-synaptic membranes. Multiple isoforms of dystrophin are present in skeletal muscle, and different isoforms could potentially be targetted to synaptic and non-synaptic membranes. We sought to determine whether the electric organ contains a single, or multiple isoforms of dystrophin, and we show here that the electric organ contains both a and b isoforms of dystrophin. Because dystrophin is found only at the postsynaptic membrane of the electric organ, we conclude that the two isoforms coexist in the postsynaptic membrane. 相似文献
5.
Danilo ML Prado Fabiana B Benatti Ana L de Sá-Pinto Ana P Hayashi Bruno Gualano Rosa MR Pereira Adriana ME Sallum Eloisa Bonfá Clovis A Silva Hamilton Roschel 《Arthritis research & therapy》2013,15(2):R46
Introduction
Exercise training has emerged as a promising therapeutic strategy to counteract physical dysfunction in adult systemic lupus erythematosus. However, no longitudinal studies have evaluated the effects of an exercise training program in childhood-onset systemic lupus erythematosus (C-SLE) patients. The objective was to evaluate the safety and the efficacy of a supervised aerobic training program in improving the cardiorespiratory capacity in C-SLE patients.Methods
Nineteen physically inactive C-SLE patients were randomly assigned into two groups: trained (TR, n = 10, supervised moderate-intensity aerobic exercise program) and non-trained (NT, n = 9). Gender-, body mass index (BMI)- and age-matched healthy children were recruited as controls (C, n = 10) for baseline (PRE) measurements only. C-SLE patients were assessed at PRE and after 12 weeks of training (POST). Main measurements included exercise tolerance and cardiorespiratory measurements in response to a maximal exercise (that is, peak VO2, chronotropic reserve (CR), and the heart rate recovery (ΔHRR) (that is, the difference between HR at peak exercise and at both the first (ΔHRR1) and second (ΔHRR2) minutes of recovery after exercise).Results
The C-SLE NT patients did not present changes in any of the cardiorespiratory parameters at POST (P > 0.05). In contrast, the exercise training program was effective in promoting significant increases in time-to-exhaustion (P = 0.01; ES = 1.07), peak speed (P = 0.01; ES = 1.08), peak VO2 (P = 0.04; ES = 0.86), CR (P = 0.06; ES = 0.83), and in ΔHRR1 and ΔHRR2 (P = 0.003; ES = 1.29 and P = 0.0008; ES = 1.36, respectively) in the C-SLE TR when compared with the NT group. Moreover, cardiorespiratory parameters were comparable between C-SLE TR patients and C subjects after the exercise training intervention, as evidenced by the ANOVA analysis (P > 0.05, TR vs. C). SLEDAI-2K scores remained stable throughout the study.Conclusion
A 3-month aerobic exercise training was safe and capable of ameliorating the cardiorespiratory capacity and the autonomic function in C-SLE patients.Trial registration
NCT01515163. 相似文献6.
Emilie M. M. Santos Wiro J. Niessen Albert J. Yoo Olvert A. Berkhemer Ludo F. Beenen Charles B. Majoie Henk. A. Marquering MR CLEAN investigators 《PloS one》2016,11(1)
Background and Purpose
In acute ischemic stroke (AIS) management, CT-based thrombus density has been associated with treatment success. However, currently used thrombus measurements are prone to inter-observer variability and oversimplify the heterogeneous thrombus composition. Our aim was first to introduce an automated method to assess the entire thrombus density and then to compare the measured entire thrombus density with respect to current standard manual measurements.Materials and Method
In 135 AIS patients, the density distribution of the entire thrombus was determined. Density distributions were described using medians, interquartile ranges (IQR), kurtosis, and skewedness. Differences between the median of entire thrombus measurements and commonly applied manual measurements using 3 regions of interest were determined using linear regression.Results
Density distributions varied considerably with medians ranging from 20.0 to 62.8 HU and IQRs ranging from 9.3 to 55.8 HU. The average median of the thrombus density distributions (43.5 ± 10.2 HU) was lower than the manual assessment (49.6 ± 8.0 HU) (p<0.05). The difference between manual measurements and median density of entire thrombus decreased with increasing density (r = 0.64; p<0.05), revealing relatively higher manual measurements for low density thrombi such that manual density measurement tend overestimates the real thrombus density.Conclusions
Automatic measurements of the full thrombus expose a wide variety of thrombi density distribution, which is not grasped with currently used manual measurement. Furthermore, discrimination of low and high density thrombi is improved with the automated method. 相似文献7.
Towards a framework for the evolutionary genomics of Kinetoplastids: what kind of data and how much?
The current status of kinetoplastids phylogeny and evolution is discussed in view of the recent progresses on genomics. Some ideas on a potential framework for the evolutionary genomics of kinetoplastids are presented. 相似文献
8.
Carlier SG Coen VL Sabaté M Kay IP Ligthart JM Van Der Giessen WJ Levendag PC Bom K Serruys PW 《International journal of cardiovascular interventions》2000,3(1):3-12
Intracoronary brachytherapy has recently emerged as a new therapy to prevent restenosis. Initial experimental work was achieved in animal models and the results were assessed by histomorphometry. Initial clinical trials used angiography to guide dosimetry and to assess efficacy. Intravascular ultrasound (IVUS) permits tomographic examination of the vessel wall, elucidating the true morphology of the lumen and transmural components, which cannot be investigated on the lumenogram obtained by angiography. This paper reviews the use of IVUS in the clinical studies of brachytherapy conducted to date. IVUS allows clinicians to make a thorough assessment of the remodeling of the vessel and appears to have a major role to play in facilitating understanding of the underlying mechanisms of action in this emerging field. The authors propose that state-of-the-art IVUS techniques should be employed to further knowledge of the mechanisms of action of brachytherapy in atherosclerotic human coronary arteries. 相似文献
9.
The release window for a given dismount from the asymmetric bars is the period of time within which release results in a successful dismount. Larger release windows are likely to be associated with more consistent performance because they allow a greater margin for error in timing the release. A computer simulation model was used to investigate optimum technique for maximizing release windows in asymmetric bars dismounts. The model comprised four rigid segments with the elastic properties of the gymnast and bar modeled using damped linear springs. Model parameters were optimized to obtain a close match between simulated and actual performances of three gymnasts in terms of rotation angle (1.5 degrees ), bar displacement (0.014 m), and release velocities (<1%). Three optimizations to maximize the release window were carried out for each gymnast involving no perturbations, 10-ms perturbations, and 20-ms perturbations in the timing of the shoulder and hip joint movements preceding release. It was found that the optimizations robust to 20-ms perturbations produced release windows similar to those of the actual performances whereas the windows for the unperturbed optimizations were up to twice as large. It is concluded that robustness considerations must be included in optimization studies in order to obtain realistic results and that elite performances are likely to be robust to timing perturbations of the order of 20 ms. 相似文献
10.
Juliana S Bernardes Alberto MR Dávila Vítor S Costa Gerson Zaverucha 《BMC bioinformatics》2007,8(1):435