首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   9篇
  免费   0篇
  2016年   1篇
  2015年   2篇
  2013年   1篇
  2012年   2篇
  2011年   1篇
  2010年   2篇
排序方式: 共有9条查询结果,搜索用时 15 毫秒
1
1.
An electrochemically amplified molecular beacon (EAMB) biosensor is constructed using thiolated hairpin DNA-ferrocene probes on gold electrode. The switching from "on" to "off" states of individual probes in the presence of complementary DNA target influences the electrode potential, besides the current, owing to changes in surface density of the electroactive hairpin DNA-ferrocene probes. The EAMB biosensor demonstrates linear range over 8 orders of magnitude with ultrasensitive detection limit of 2.3 × 10(-14)M for the quantification of a 21-mer DNA sequence. Its applicability is tested against PCR amplicons derived from genomic DNA of live Legionella pneumophila. Excellent specificity down to one and three nucleotides mismatches in another strain of L. pneumophila and a different bacterium species, respectively, is demonstrated.  相似文献   
2.
Multimodal monitoring of brain state is important both for the investigation of healthy cerebral physiology and to inform clinical decision making in conditions of injury and disease. Near-infrared spectroscopy is an instrument modality that allows non-invasive measurement of several physiological variables of clinical interest, notably haemoglobin oxygenation and the redox state of the metabolic enzyme cytochrome c oxidase. Interpreting such measurements requires the integration of multiple signals from different sources to try to understand the physiological states giving rise to them. We have previously published several computational models to assist with such interpretation. Like many models in the realm of Systems Biology, these are complex and dependent on many parameters that can be difficult or impossible to measure precisely. Taking one such model, BrainSignals, as a starting point, we have developed several variant models in which specific regions of complexity are substituted with much simpler linear approximations. We demonstrate that model behaviour can be maintained whilst achieving a significant reduction in complexity, provided that the linearity assumptions hold. The simplified models have been tested for applicability with simulated data and experimental data from healthy adults undergoing a hypercapnia challenge, but relevance to different physiological and pathophysiological conditions will require specific testing. In conditions where the simplified models are applicable, their greater efficiency has potential to allow their use at the bedside to help interpret clinical data in near real-time.  相似文献   
3.
Overexpression of recombinant Fc fusion proteins in Escherichia coli frequently results in the production of inclusion bodies that are subsequently used to produce fully functional protein by an in vitro refolding process. During the refolding step, misfolded proteins such as disulfide scrambled forms can be formed, and purification steps are used to remove these product-related impurities to produce highly purified therapeutic proteins. A variety of analytical methods are commonly used to monitor protein variants throughout the purification process. Capillary electrophoresis (CE)-based techniques are gaining popularity for such applications. In this work, we used a nonreduced capillary electrophoresis–sodium dodecyl sulfate (nrCE–SDS) method for the analysis of disulfide scrambled forms in a fusion protein. Under denatured nonreduced conditions, an extra post-shoulder peak was observed at all purification steps. Detailed characterization revealed that the peak was related to the disulfide scrambled forms and was isobaric with the correctly folded product. In addition, when sodium dodecyl sulfate–polyacrylamide gel electrophoresis (SDS–PAGE) was used during the CE–SDS peak characterization, we observed that the migration order of scrambled forms is reversed on CE–SDS versus SDS–PAGE. This illustrates the importance of establishing proper correlation of these two techniques when they are used interchangeably to guide the purification process and to characterize proteins.  相似文献   
4.
5.
A molecular diagnostic platform with DANP-anchored hairpin primer was developed and evaluated for the rapid and cost-effective detection of Chikungunya virus (CHIKV) with high sensitivity and specificity. The molecule 2, 7-diamino-1, 8-naphthyridine (DANP) binds to a cytosine-bulge and emits fluorescence at 450 nm when it is excited by 400 nm light. Thus, by measuring the decline in fluorescence emitted from DANP—primer complexes after PCR reaction, we could monitor the PCR progress. By adapting this property of DANP, we have previously developed the first generation DANP-coupled hairpin RT-PCR assay. In the current study, we improved the assay performance by conjugating the DANP molecule covalently onto the hairpin primer to fix the DANP/primer ratio at 1:1; and adjusting the excitation emission wavelength to 365/430 nm to minimize the background signal and a ‘turn-on’ system is achieved. After optimizing the PCR cycle number to 30, we not only shortened the total assay turnaround time to 60 minutes, but also further reduced the background fluorescence. The detection limit of our assay was 0.001 PFU per reaction. The DANP-anchored hairpin primer, targeting nsP2 gene of CHIKV genome, is highly specific to CHIKV, having no cross-reactivity to a panel of other RNA viruses tested. In conclusion, we report here a molecular diagnostic assay that is sensitive, specific, rapid and cost effective for CHIKV detection and can be performed where no real time PCR instrumentation is required. Our results from patient samples indicated 93.62% sensitivity and 100% specificity of this method, ensuring that it can be a useful tool for rapid detection of CHIKV for outbreaks in many parts of the world.  相似文献   
6.
Hypoxia-ischaemia (HI) is a major cause of neonatal brain injury, often leading to long-term damage or death. In order to improve understanding and test new treatments, piglets are used as preclinical models for human neonates. We have extended an earlier computational model of piglet cerebral physiology for application to multimodal experimental data recorded during episodes of induced HI. The data include monitoring with near-infrared spectroscopy (NIRS) and magnetic resonance spectroscopy (MRS), and the model simulates the circulatory and metabolic processes that give rise to the measured signals. Model extensions include simulation of the carotid arterial occlusion used to induce HI, inclusion of cytoplasmic pH, and loss of metabolic function due to cell death. Model behaviour is compared to data from two piglets, one of which recovered following HI while the other did not. Behaviourally-important model parameters are identified via sensitivity analysis, and these are optimised to simulate the experimental data. For the non-recovering piglet, we investigate several state changes that might explain why some MRS and NIRS signals do not return to their baseline values following the HI insult. We discover that the model can explain this failure better when we include, among other factors such as mitochondrial uncoupling and poor cerebral blood flow restoration, the death of around 40% of the brain tissue.  相似文献   
7.
V Rai  HC Hapuarachchi  LC Ng  SH Soh  YS Leo  CS Toh 《PloS one》2012,7(8):e42346
A nanoporous alumina membrane-based ultrasensitive DNA biosensor is constructed using 5'-aminated DNA probes immobilized onto the alumina channel walls. Alumina nanoporous membrane-like structure is carved over platinum wire electrode of 76 μm diameter dimension by electrochemical anodization. The hybridization of complementary target DNA with probe DNA molecules attached inside the pores influences the pore size and ionic conductivity. The biosensor demonstrates linear range over 6 order of magnitude with ultrasensitive detection limit of 9.55×10(-12) M for the quantification of ss-31 mer DNA sequence. Its applicability is challenged against real time cDNA PCR sample of dengue virus serotype1 derived from asymmetric PCR. Excellent specificity down to one nucleotide mismatch in target DNA sample of DENV3 is also demonstrated.  相似文献   
8.

Background

The sensitivity and specificity of two in-house MAC-ELISA assays were tested and compared with the performance of commercially-available CTK lateral flow rapid test and EUROIMMUN IFA assays for the detection of anti-Chikungunya virus (CHIKV) IgM. Each MAC-ELISA assay used a whole virus-based antigen derived from genetically distinct CHIKV strains involved in two chikungunya disease outbreaks in Singapore (2008); a January outbreak strain with alanine at amino acid residue 226 of the E1 glycoprotein (CHIKV-A226) and a May-to-September outbreak strain that possessed valine at the same residue (CHIKV-226V). We report differences in IgM detection efficacy of different assays between the two outbreaks. The sensitivities of two PCR protocols were also tested.

Methods and Findings

For sera from January outbreak, the average detection threshold of CTK lateral flow test, MAC-ELISAs and EUROIMMUN IFA assays was 3.75, 4.38 and 4.88 days post fever onset respectively. In contrast, IgM detection using CTK lateral flow test was delayed to more than 7 days after fever onset in the second outbreak sera. However, MAC-ELISA using CHIKV-226V detected IgM in the second outbreak sera 3.96 days after fever onset, which was approximately one day earlier compared to the same assay using CHIKV-A226 (4.86 days). Specificity was 100% for both commercial assays, and 95.6% for the in-house MAC-ELISAs. For sensitivity determination of the PCR protocols, the probe-based real time RT-PCR method was found to be 10 times more sensitive than one based on SYBR Green.

Conclusion

Our findings suggested that the two strains of CHIKV using variants A226 and 226V resulted in variation in sensitivities of the assays evaluated. We postulated that the observed difference in antigen efficacy could be due to the amino acid substitution differences in viral E1 and E2 envelope proteins, especially the E1-A226V substitution. This evaluation demonstrates the importance of appraisal of different diagnostic assays before their application in clinical and operational settings.  相似文献   
9.
The process known as vasomotion, rhythmic oscillations in vessel diameter, has been proposed to act as a protective mechanism for tissue under conditions of reduced perfusion, since it is frequently only observed experimentally when perfusion levels are reduced. This could be due to a resultant increase in oxygen transport from the vasculature to the surrounding tissue, either directly or indirectly. It is thus potentially of significant clinical interest as a warning signal for ischemia. However, there has been little analysis performed to quantify the effects of vessel wall movement on time-averaged mass transport. We thus present a detailed analysis of such mass transport for an axisymmetric vessel with a periodically oscillating wall, by solving the non-linear mass transport equation, and quantify the differences between the time-averaged mass transport under conditions of no oscillation (i.e. the steady-state) and varying wall oscillation amplitude. The results show that if the vessel wall alone is oscillated, with an invariant wall concentration, the time-averaged mass transport is reduced relative to the steady-state, but if the vessel wall concentration is also oscillated, then mass transport is increased, although this is generally only true when these oscillate in phase with each other. The influence of Péclet number and the non-dimensional rate of consumption of oxygen in tissue, as well as the amplitude of oscillations, are fully characterised. We conclude by considering the likely implications of these results in the context of oxygen transport to tissue.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号