全文获取类型
收费全文 | 67篇 |
免费 | 9篇 |
出版年
2023年 | 2篇 |
2022年 | 1篇 |
2020年 | 1篇 |
2018年 | 1篇 |
2017年 | 2篇 |
2016年 | 3篇 |
2015年 | 2篇 |
2014年 | 1篇 |
2013年 | 3篇 |
2012年 | 7篇 |
2010年 | 2篇 |
2009年 | 4篇 |
2008年 | 2篇 |
2007年 | 5篇 |
2006年 | 5篇 |
2005年 | 5篇 |
2004年 | 5篇 |
2003年 | 2篇 |
2001年 | 3篇 |
2000年 | 1篇 |
1999年 | 1篇 |
1998年 | 1篇 |
1992年 | 1篇 |
1991年 | 1篇 |
1984年 | 1篇 |
1983年 | 4篇 |
1981年 | 2篇 |
1978年 | 1篇 |
1975年 | 1篇 |
1973年 | 1篇 |
1970年 | 2篇 |
1967年 | 2篇 |
1965年 | 1篇 |
排序方式: 共有76条查询结果,搜索用时 15 毫秒
1.
Preparation of novel 9-pyrrolo-9-deoxoerythromycin A analogs from 9-(S) and (R, erythromycylamines by the Clauson-Kass and Wasserman reactions is described. The biological activities of these novel analogs are also reported. 相似文献
2.
R Shankaran M Ameen W L Daniel R G Davidson P L Chang 《Biochimica et biophysica acta》1991,1078(2):251-257
Arylsulfatase C and steroid sulfatase were thought to be identical enzymes. However, recent evidence showed that human arylsulfatase C consists of two isozymes, s and f. In this study, the biochemical properties of the s form partially purified from human placenta were compared with those of the f form from human liver. Only the placental s form has steroid sulfatase activity and hydrolyses estrone sulfate, dehydroepiandrosterone sulfate and cholesterol sulfate. The liver f form has barely detectable activity towards these sterol sulfates. With the artificial substrate, 4-methylumbelliferyl sulfate, both forms demonstrated a similar KM but the liver enzyme has a pH optimum of 6.9 while the placental form displayed two optima at 7.3 and 5.5. The molecular weight of the native enzyme determined with gel filtration was 183,000 for the s form and 200,000 for the f form and their pI's were also similar at 6.5. However, the T50, temperature at which half of the enzyme activity was lost, was 49.5 degrees C for the f form and 56.8 degrees C for the s form. Polyclonal antibodies raised against the placental form reacted specifically against the s and not the f form. They immuno-precipitated concomitantly greater than 80% of the total placental arylsulfatase C and steroid sulfatase activities while less than 20% of the liver enzyme was immuno-precipitable. In conclusion, the two isozymes s and f of arylsulfatase C in humans purified from placenta and liver, respectively, have similar KM, pI' and native molecular weight. However, they are distinct proteins with different substrate specificity, pH optima, heat-lability and antigenic properties. Only the s form is confirmed to be steroid sulfatase. 相似文献
3.
Nripendra Vikram Singh Shilpa Parashuram Jyotsana Sharma Roopa Sowjanya Potlannagari Dhinesh Babu Karuppannan Ram Krishna Pal Prakash Patil Dhananjay M. Mundewadikar Vipul R. Sangnure P.V. Parvati Sai Arun Naresh V.R. Mutha Bipin Kumar Abhishek Tripathi Sathish Kumar Peddamma Harish Kothandaraman Sailu Yellaboina Dushyant Singh Baghel Umesh K. Reddy 《Saudi Journal of Biological Sciences》2020,27(12):3514-3528
4.
Although selective or whole body cooling combined with optimal intensive care improves outcomes following neonatal encephalopathy in high-income countries, the safety and efficacy of cooling in low-and middle-income countries is not known.
Objective
We performed a systematic review and meta-analysis of all published randomised or quasi-randomised controlled trials of cooling therapy for neonatal encephalopathy in low-and middle-income countries.Results
Seven trials, comprising a total of 567 infants were included in the meta-analysis. Most study infants had mild (15%) or moderate encephalopathy (48%) and did not receive invasive ventilation (88%). Cooling devices included water-circulating cooling caps, frozen gel packs, ice, water bottles, and phase-changing material. No statistically significant reduction in neonatal mortality was seen with cooling (risk ratio: 0.74, 95% confidence intervals: 0.44 to 1.25). Data on other neonatal morbidities and long-term neurological outcomes were insufficient.Conclusion
Cooling therapy was not associated with a statistically significant reduction in neonatal mortality in low-and middle-income countries although the confidence intervals were wide and not incompatible with results seen in high-income countries. The apparent lack of treatment effect may be due to the heterogeneity and poor quality of the included studies, inefficiency of the low technology cooling devices, lack of optimal neonatal intensive care, sedation and ventilatory support, overuse of oxygen, or may be due to the intrinsic difference in the population, for example higher rates of perinatal infection, obstructed labor, intrauterine growth retardation and maternal malnutrition. Evaluation of the safety and efficacy of cooling in adequately powered randomised controlled trials is required before cooling is offered in routine clinical practice in low-and middle-income countries. 相似文献5.
Rajesh Thiyagarajan Arunai Nambiraj Sujit Nath Sinha Girigesh Yadav Ashok Kumar Vikraman Subramani Kothandaraman 《Reports of Practical Oncology and Radiotherapy》2016,21(1):50-56
Aim
The aim of this study is to evaluate performance of ArcCHECK diode array detector for the volumetric modulated arc therapy (VMAT) patient specific quality assurance (QA). VMAT patient specific QA results were correlated with ion chamber measurement. Dose response of the ArcCHECK detector was studied.Background
VMAT delivery technique improves the dose distribution. It is complex in nature and requires proper QA before its clinical implementation. ArcCHECK is a novel three dimensional dosimetry system.Materials and methods
Twelve retrospective VMAT plans were calculated on ArcCHECK phantom. Point dose and dose map were measured simultaneously with ion chamber (IC-15) and ArcCHECK diode array detector, respectively. These measurements were compared with their respective TPS calculated values.Results
The ion chamber measurements are in good agreement with TPS calculated doses. Mean difference between them is 0.50% with standard deviation of 0.51%. Concordance correlation coefficient (CCC) obtained for ion chamber measurements is 0.9996. These results demonstrate a strong correlation between the absolute dose predicted by our TPS and the measured dose. The CCC between ArcCHECK doses and TPS predictions on the CAX was found to be 0.9978. In gamma analysis of dose map, the mean passing rate was 98.53% for 3% dose difference and 3 mm distance to agreement.Conclusions
The VMAT patient specific QA with an ion chamber and ArcCHECK phantom are consistent with the TPS calculated dose. Statistically good agreement was observed between ArcCHECK measured and TPS calculated. Hence, it can be used for routine VMAT QA. 相似文献6.
Differential recovery of membrane proteins after extraction by aqueous methanol and trifluoroethanol
Zhang H Lin Q Ponnusamy S Kothandaraman N Lim TK Zhao C Kit HS Arijit B Rauff M Hew CL Chung MC Joshi SB Choolani M 《Proteomics》2007,7(10):1654-1663
Cell membrane proteome analysis is limited by inherent membrane hydrophobicity. Conventional membrane protein extraction techniques use detergents, chaotropes and organic acids that require sample clean-up or pH adjustment, and are associated with significant sample loss. We extracted membrane proteins from red blood cells (RBCs) using methanol (MeOH), trifluoroethanol (TFE) and urea, and identified membrane proteins using 2-D LC coupled with MALDI-TOF/TOF-MS. We show that organic solvents MeOH- and TFE-based methods have membrane protein analysis efficiencies comparable to urea, and are complementary for the recovery of both hydrophilic and hydrophobic peptides. The mean grand average of hydropathicity (GRAVY) value of identified peptides from the TFE-based method (-0.107) was significantly higher than that of the MeOH-based method (-0.465) (p<0.001). Sequential and adjunctive use of the organic solvents MeOH and TFE increases the number of proteins identified, and the confidence of their identification. We show that this strategy is effective for shotgun membrane proteome analysis. 相似文献
7.
Receptors constitute the interface of cells to their external environment. These molecules bind specific ligands involved in multiple processes, such as signal transduction and nutrient transport. Although a variety of cell surface receptors undergo endocytosis, the systems-level design principles that govern the evolution of receptor trafficking dynamics are far from fully understood. We have constructed a generalized mathematical model of receptor–ligand binding and internalization to understand how receptor internalization dynamics encodes receptor function and regulation. A given signaling or transport receptor system represents a particular implementation of this module with a specific set of kinetic parameters. Parametric analysis of the response of receptor systems to ligand inputs reveals that receptor systems can be characterized as being: i) avidity-controlled where the response control depends primarily on the extracellular ligand capture efficiency, ii) consumption-controlled where the ability to internalize surface-bound ligand is the primary control parameter, and iii) dual-sensitivity where both the avidity and consumption parameters are important. We show that the transferrin and low-density lipoprotein receptors are avidity-controlled, the vitellogenin receptor is consumption-controlled, and the epidermal growth factor receptor is a dual-sensitivity receptor. Significantly, we show that ligand-induced endocytosis is a mechanism to enhance the accuracy of signaling receptors rather than merely serving to attenuate signaling. Our analysis reveals that the location of a receptor system in the avidity-consumption parameter space can be used to understand both its function and its regulation. 相似文献
8.
Nonlinear flow affects hydrodynamic forces and neutrophil adhesion rates in cone-plate viscometers
下载免费PDF全文
![点击此处可从《Biophysical journal》网站下载免费的PDF全文](/ch/ext_images/free.gif)
We present a theoretical and experimental analysis of the effects of nonlinear flow in a cone-plate viscometer. The analysis predicts that flow in the viscometer is a function of two parameters, the Reynolds number and the cone angle. Nonlinear flow occurs at high shear rates and causes spatial variations in wall shear stress, collision frequency, interparticle forces and attachment times within the viscometer. We examined the effect of these features on cellular adhesion kinetics. Based on recent data (Taylor, A. D., S. Neelamegham, J. D. Hellums, et al. 1996. Biophys. J. 71:3488-3500), we modeled neutrophil homotypic aggregation as a process that is integrin-limited at low shear and selectin-limited at high shear. Our calculations suggest that selectin and integrin on-rates lie in the order of 10(-2)-10(-4)/s. They also indicate that secondary flow causes positional variations in adhesion efficiency in the viscometer, and that the overall efficiency is dependent not only on the shear rate, but also the sample volume and the cone angle. Experiments performed with isolated neutrophils confirmed these predictions. In these experiments, enhancing secondary flow by increasing the sample volume from 100 to 1000 microl at 1500/s for a 2 degrees cone caused up to an approximately 45% drop in adhesion efficiency. Our results suggest that secondary flow may significantly influence cellular aggregation, platelet activation, and endothelial cell mechanotransduction measurements made in the viscometer over the range of conditions applied in typical biological studies. 相似文献
9.
Kumbhat S Shankaran DR Kim SJ Gobi KV Joshi V Miura N 《Biosensors & bioelectronics》2007,23(3):421-427
In modern biomedical technology, development of high performance sensing methods for dopamine (DA) is a critical issue because of its vital role in human metabolism. We report here, a new kind of bioaffinity sensor for DA based on surface plasmon resonance (SPR) using a D(3) dopamine receptor (DA-RC) as a recognition element. A conjugate of DA was synthesized using bovine serum albumin (BSA) protein and was characterized by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). The biosensor surface was constructed by the immobilization of the DA-BSA conjugate onto an SPR gold surface by physical adsorption. Atomic force microscopy (AFM) investigations revealed that the DA-BSA conjugate was homogeneously distributed over the sensor surface. Specific interaction of the DA-RC with the immobilized DA-BSA conjugate was studied by SPR. Based on the principle of indirect competitive inhibition, the biosensor could detect DA in a linear dynamic range from 85 pg/ml (ppt) to 700 ng/ml (ppb). The biosensor was highly specific for DA and showed no significant interference from potent interferences such as ascorbic acid (AA), uric acid (UA) and other DA analogues viz., 3,4 dihydroxyphenyl acetic acid (DOPAC) and 3-(3,4 dihydroxyphenyl)-alanine (DOPA). The sensor surface displayed a high level of stability during repeated regeneration and affinity reaction cycles. Since this biosensor is simple, effective and is based on utilization of natural receptor, our study presents an encouraging scope for development of portable detection systems for in-vitro and in-vivo measurement of DA in clinical and medical diagnostics. 相似文献
10.
Jeansonne DP Bordes TJ Bennett CA Kothandaraman G Bush JG Vaccaro JA 《Protein expression and purification》2006,46(2):240-247
The non-receptor tyrosine kinase c-Src plays a central role in a variety of cell signaling pathways that regulate cell growth, differentiation, apoptosis, and other important cellular processes. An 85-amino acid N-terminal deletion construct of c-Src (DeltaN85 c-Src) has been structurally characterized and used extensively in biochemical and biophysical studies. In this report, we have established a relatively rapid, simplified purification of DeltaN85 c-Src from recombinant baculovirus-infected insect cells. Q-Sepharose anion-exchange and aminophenyl-ATP affinity chromatography were used to isolate 5mg of >98% pure DeltaN85 c-Src from 900 mg of total soluble protein. The specific activity of DeltaN85 c-Src (20 U mg(-1)) was found to be >or = 5-fold greater than previously reported values. A lag in the autophosphorylation kinetics of DeltaN85 c-Src was observed, and the reaction occurred with observed first-order rate constants k1=0.20+/-0.01 min(-1) and k2=0.38+/-0.01 min(-1) under the experimental conditions used. Steady-state kinetic analysis of peptide phosphorylation by DeltaN85 c-Src gave Km values of 99+/-23 microM and 190+/-30 microM for the peptide and ATP substrates, respectively, and a value of k(cat)=17+/-2s(-1). Overall, we present a dramatically improved purification strategy that represents a simplified, relatively rapid protocol for the isolation of milligram quantities of DeltaN85 c-Src required for rigorous structure-function and inhibition studies that rely on a pre-steady-state kinetic approach. 相似文献