首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   61篇
  免费   1篇
  国内免费   2篇
  2020年   1篇
  2019年   3篇
  2018年   1篇
  2016年   2篇
  2015年   1篇
  2014年   2篇
  2013年   6篇
  2012年   11篇
  2011年   11篇
  2010年   2篇
  2008年   3篇
  2006年   2篇
  2005年   1篇
  2004年   2篇
  2002年   3篇
  2001年   1篇
  2000年   2篇
  1999年   4篇
  1998年   1篇
  1986年   1篇
  1985年   2篇
  1984年   2篇
排序方式: 共有64条查询结果,搜索用时 62 毫秒
1.
An indole 2,3-dioxygenase was purified ca 38-fold from maize leaves. The enzyme had an MW of about 98000, an optimum pH of 5.0 and the energy of activation was 9.1 kcal/mol. The Kmax for indole was 1.4 × 10?4 M. The enzyme was inhibited by diethyldithiocarbamate, salicylaldoxime and sodium dithionite. The inhibition by diethyldithiocarbamate was specifically reversed by Cu2+. The dialysed enzyme was stimulated by Cu2+. Four atoms of oxygen were utilized in the disappearance of 1 mole of indole. Inhibition of the enzyme by -SH compounds and -SH group inhibitors, and their partial removal by Cu2+ only, suggested the involvement of -SH groups in binding of Cu2+ at the catalytic site.  相似文献   
2.
A method is described for construction of an amperometric triglyceride (TG) biosensor based on covalent co-immobilization of lipase, glycerol kinase and glycerol-3-phosphate oxidase onto gold polypyrrole nanocomposite decorated poly indole-5-carboxylic acid electrodeposited on the surface of a gold electrode. The enzyme electrode was characterized by transmission electron microscopy, scanning electron microscopy, electrochemical impedance studies, Fourier transform infrared spectroscopy and cyclic voltammetry. Biosensor showed optimum response within 4 s at pH 6.5 and 35 °C, when polarized at +0.1 V against Ag/AgCl. There was a linear relationship between sensor response and triolein concentration in the range 50–700 mg/dl. Biosensor was employed for determination of TG in serum. Detection limit of the biosensor was 20 mg/dl. Biosensor was evaluated with 91–95 % recovery of added triolein in sera and 4.14 and 5.85 % within and between batch coefficients of variation, respectively. There was a good correlation (r = 0.99) between sera TG values by standard method (Enzymic colorimetric) and the present method. The biosensor was unaffected by a number of serum substances at their physiological concentration. Biosensor lost 50 % of its initial activity after its 100 uses over 7 months, when stored at 4 °C.  相似文献   
3.
A nickel hexacyanoferrate polypyrrole film was synthesized through an electrochemical two-step methodology leading to a very stable and homogenous robust hybrid film. A highly sensitive, specific and rapid amperometric d-amino acid biosensor was constructed by immobilizing d-amino acid oxidase on this film deposited over the surface of a glassy carbon electrode. The modified electrode was characterized by scanning electron microscopy, electrochemical impedance spectroscopy and Fourier transform infrared spectrophotometry. The biosensor showed optimum response within 1 s, when operated at 50 mV s?1 in 0.01 M Tris HCl buffer, pH 7.0 at 30 °C. The biosensor exhibited excellent sensitivity with a detection limit of 1.5 µM (S/N = 3) for d-amino acids and wider linear range, 20–500 µM. Analytical recovery of added d-alanine (5 and 10 mM) in serum samples was 98.00 and 98.80 %, respectively. Within-batch and between-batch coefficients of variation in serum samples were 1.36 and 2.77 %, respectively. The enzyme electrode was used more than 50 times over 2 months, when stored at 4 °C. The proposed modified electrode exhibited sufficient mechanical and electrochemical stability and high sensitivity compared to earlier electrochemical d-amino acid biosensors. Interference by ascorbic acid and uric acid, the main interfering species in the biological samples, was negligible.  相似文献   
4.
A novel amperometric lactate biosensor was developed based on immobilization of lactate dehydrogenase onto graphene oxide nanoparticles‐decorated pencil graphite electrode. The enzyme electrode was characterized by scanning electron microscopy, Fourier transform infrared spectroscopy (FTIR), and cyclic voltammetry at different stages of its construction. The biosensor showed optimum response within 5 s at pH 7.3 (0.1 M sodium phosphate buffer) and 35°C, when operated at 0.7 V. The biosensor exhibited excellent sensitivity (detection limit as low as 0.1 μM), fast response time (5 s), and wider linear range (5–50 mM). Analytical recovery of added lactic acid in serum was between 95.81–97.87% and within‐batch and between‐batch coefficients of variation were 5.04 and 5.40%, respectively. There was a good correlation between serum lactate values obtained by standard colorimetric method and the present biosensor (r = 0.99). The biosensor measured lactate levels in sera of apparently healthy subjects and persons suffering from lactate acidosis and other biological materials (milk, curd, yogurt, beer, white wine, and red wine). The enzyme electrode lost 25% of its initial activity after 60 days of its regular uses, when stored dry at 4°C.  相似文献   
5.
A method for determination of serum triglycerides (Tgs) using lipase, glycerol kinase, glycerol-3-phosphate oxidase and peroxidase co-immobilized onto alkylamine glass beads (pore diameter 55 nm) through glutaraldehyde coupling was developed and evaluated. The minimum detection limit of the method was 0.54 mM. The analytical recovery of added triolein in the serum was 97.55 +/- 1.5% (mean +/- S.D.). The mean value of serum Tgs, determined by the present method showed a good correlation (r = 0.984) with the Bayer's kit method, employing free enzymes. The within and between batch coefficients of variation (CV) were < 2.25% and < 1.35% respectively. No significant loss of activity was observed, when co-immobilized enzymes were reused for about 200 times and stored at 4 degrees C in distilled water. The cost of Tg determination for 200 serum samples was less, as compared with Bayer's kit method.  相似文献   
6.
The measurement of oxalate in urine was improved by employing barley oxalate oxidase immobilized on alkylamine glass beads affixed in a glass beaker. The minimum detection limit was 3.6 mg l(-1) urine. The recovery of added oxalate was 88.9+/-9.2%. Within- and between-assay coefficients of variation (CV) were <4.0 and <9.4%, respectively. The urinary oxalate values were obtained by a commercial kit method and the present method showed a good correlation (0.999). The method is free from tedious handling of glass beads and Cl- interference.  相似文献   
7.
We have reported a simple method of determination of plasma oxalate using a Cl(-) and NO(3)(-) insensitive oxalate oxidase purified from grain sorghum leaf and commercially available peroxidase from horseradish [Pundir et al., Ind. J. Biochem. Biophys., 35 (1998) 120-122]. The present report describes the immobilization of both the enzymes onto alkylamine glass, their kinetic properties and application for discrete analysis of plasma oxalate. In the analytic method, H(2)O(2) generated from plasma oxalate by immobilized oxalate oxidase is measured colorimetrically at 520 nm by oxidative coupling with 4-aminophenazone, and phenol catalyzed by immobilized peroxidase. The minimum detection limit of the method is 2.5 micromol/l. Analytic recovery of added oxalate in plasma was 89. 5+/-4.1% (mean+/-S.D.). The within and between day CV for plasma oxalate measurement were <9.37 and <11.0%, respectively. The normal range of plasma oxalate as measured by the present method was 3.6 to 5.7 micromol/l. The method is not only free from interference by plasma Cl(-) and NO(3)(-) but also provides the reuse of glass beads and thus reduces the cost of analysis for routine.  相似文献   
8.
Commercial lipase, glycerol kinase (GK), glycerol-3-phosphate oxidase (GPO) and peroxidase (POD) have been co-immobilized covalently on to arylamine glass beads affixed on a plastic strip through diazotization with a conjugation yield of 89.1 mg/g support and 64.1% retention of specific activity. The co-immobilized enzymes showed maximum activity at pH 7.5, when incubated at 40 degrees C for 20 min. The strip was employed for determination of serum triglycerides (Tgs). The minimum detection limit of the method was 0.20 mM/L. The recovery of added Tgs was 88.0%. Within day and between day coefficient of variations were <7.0 % and <11.0%, respectively. A good correlation (r = 0.982) was observed between total serum Tgs values obtained by present method and the most commonly used enzymic colorimetric method, employing free enzymes. Among the various serum substances tested at their physiological concentrations, only cholesterol, ascorbic acid and bilirubin caused 30%, 15%, and 20% inhibition of strip-bound enzymes, respectively. The strip lost 50% of its activity after 150 regular uses over a period of 33 days, when stored in reaction buffer at 4 degrees C. The method reported here has the advantage over other existing methods, as it provides higher sensitivity, better stability and reusability of co-immobilized enzymes and is also economical.  相似文献   
9.
Polyvinyl chloride (PVC) sheets are a promising material for enzyme immobilization owing to the PVC’s properties such as being chemically inert, corrosion free, weather resistant, tough, lightweight, and maintenance free and having a high strength-to-weight ratio. In this study, this attractive material surface was chemically modified and exploited for covalent immobilization of oxalate oxidase using glutaraldehyde as a coupling agent. The enzyme was immobilized on activated PVC surface with a conjugation yield of 360 μg/cm2. The scanning electron micrographs showed the microstructures on the PVC sheet surface revealing the successful immobilization of oxalate oxidase. A colorimetric method was adopted in evaluating enzymatic activity of immobilized and native oxalate oxidase. The immobilized enzyme retained 65% of specific activity of free enzyme. Slight changes were observed in the optimal pH, incubation temperature, and time for maximum activity of immobilized oxalate oxidase. PVC support showed no interference when immobilized oxalate oxidase was used for estimation of oxalic acid concentration in urine samples and showed a correlation of 0.998 with the values estimated with a commercially available Sigma kit. The overall results strengthen our view that PVC sheet can be used as a solid support for immobilization of enzymes and in the field of clinical diagnostics, environmental monitoring and remediation.  相似文献   
10.
The effect of NaCl stress on molecular and biochemical properties of oxalate oxidase (OXO) was studied in leaves of grain sorghum hybrid (var CSH-14) seedlings. There was no effect on molecular weight and number of subunits of the enzyme but it showed some important changes in its kinetic parameters such as Km for oxalate and Vmax. Optimum pH (5.8), activation energy (5.084 kcal mole?1), time of incubation (6 min) and Km for oxalate (1.21×10t-4M) were increased, while Vmax (0.182 mmole min?1) decreased and no change in optimum temperature was observed. This showed that substrate affinity and maximum activity of the enzyme was adversely affected. The specific activity of oxalate oxidase was increased in seedlings grown in a NaCl containing medium compared to normal, which reveals the increased de novo synthesis of the enzyme to sustain oxalate degradation.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号