首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   17篇
  免费   2篇
  2016年   1篇
  2015年   1篇
  2013年   1篇
  2012年   2篇
  2011年   3篇
  2009年   1篇
  2008年   2篇
  2007年   3篇
  2006年   2篇
  2005年   1篇
  2004年   1篇
  2000年   1篇
排序方式: 共有19条查询结果,搜索用时 15 毫秒
1.
A microfluidic conductimetric bioreactor has been developed. Enzyme was immobilized in the microfluidic channel on poly-dimethylsiloxane (PDMS) surface via covalent binding method. The detection unit consisted of two gold electrodes and a laboratory-built conductimetric transducer to monitor the increase in the conductivity of the solution due to the change of the charges generated by the enzyme-substrate catalytic reaction. Urea–urease was used as a representative analyte-enzyme system. Under optimum conditions urea could be determined with a detection limit of 0.09 mM and linearity in the range of 0.1–10 mM (r = 0.9944). The immobilized urease on the microchannel chip provided good stability (>30 days of operation time) and good repeatability with an R.S.D. lower than 2.3%. Good agreement was obtained when urea concentrations of human serum samples determined by the microfluidic flow injection conductimetric bioreactor system were compared to those obtained using the Berthelot reaction (P < 0.05). After prolong use the immobilized enzyme could be removed from the PDMS microchannel chip enabling new active enzyme to be immobilized and the chip to be reused.  相似文献   
2.
Detecting penicillin G in milk with impedimetric label-free immunosensor   总被引:1,自引:0,他引:1  
A label-free impedimetric flow injection immunosensor for the direct detection of penicillin G has been developed. Anti-penicillin G was immobilized on a gold working electrode modified with a self-assembled monolayer of thioctic acid. Real time monitoring of impedance was carried out at the optimum frequency of 160 Hz. Under optimum operating conditions the system provided a wide linear range between 1.0 x 10(-13) and 1.0 x 10(-8) M with a very low detection limit of 3.0 x 10(-15) M, much lower than the MRL of penicillin G in milk (1.2 x 10(-8) M). The immobilized anti-penicillin G on self-assembled thioctic acid monolayer gold electrode was very stable and provided good reproducible signal after regeneration up to 45 times with a relative standard deviation (R.S.D.) lower than 4%. Good recoveries and precisions were obtained when spiked raw milk samples were analyzed.  相似文献   
3.
A real-time capacitive sensor based on a potentiostatic step method was developed. It can display in real-time the evoked current waveform, capacitance and the electrical resistance of elements serially connected to the insulation layer on the electrode as a function of time as well as the ohmic resistance of the insulation layer. These features enable the user to observe the association and dissociation of the affinity binding pairs and to evaluate the insulating property of the electrode surface during measurement. The system allows the setting of potential pulse height, pulse interval, gain, filter, and sampling frequency, enabling the system to be more flexible. The performance of the system was firstly evaluated with equivalent circuits. Under suitable parameter settings it provided good accuracy of both the capacitance and resistance. Using the affinity binding pair of human serum albumin (HSA) and anti human serum albumin (anti-HSA) the measured capacitance change was used for the direct detection of HSA. The developed system provided the same sensitivity as the commercially available potentiostat (P>0.05). The proposed system was then applied to analyse HSA in real urine samples and the results agreed well with the immunoturbidimetric assay (P>0.05). The proposed system can be applied for capacitance measurement to directly detect other target analytes using different affinity binding pairs. Other applications such as kinetics analysis of the interaction between affinity bindings, thickness analysis, and the study of the insulation property of the modified layer are also promising.  相似文献   
4.
Two flow-injection biosensor systems using semi disposable enzyme reactor have been developed to determine carbamate pesticides in water samples. Acetylcholinesterase was immobilized on silica gel by covalent binding. pH and conductivity electrodes were used to detect the ionic change of the sample solution due to hydrolysis of acetylcholine. Carbamate pesticides inhibited acetylcholinesterase and the decrease in the enzyme activity was used to determine these pesticides. Parameters influencing the performance of the systems were optimized to be used in the inhibition procedure. Carbofuran and carbaryl were used to test these systems. Detection limits for the potentiometric and conductimetric systems were both at 10% inhibition corresponding to 0.02 and 0.3 ppm of carbofuran and carbaryl, respectively. Both systems also provided the same linear ranges, 0.02-8.0 ppm for carbofuran, and 0.3-10 ppm for carbaryl. The analysis of pesticides was done a few times before the reactor was disposed. Percentages of inhibition obtained from different reactors were reproducible, therefore, no recalibration was necessary when changing the reactor. The biosensors were used to analyze carbaryl in water samples from six wells in a vegetable growing area. Both systems could detect the presence of carbaryl in the samples and provided good recoveries of the added carbaryl, i.e., 80-106% for the potentiometric system and 75-105% for the conductimetric system. The presence of carbaryl in water samples analyzed by the biosensors was confirmed by gas chromatography-mass spectrometric system. These biosensors do not require any sample preconcentration and are suitable for detecting pesticides in real water samples.  相似文献   
5.
This paper reports, for the first time, the influence of the length and the terminating head group of blocking thiols on the sensitivity and specificity of a label-free capacitive DNA detection system using immobilized pyrrolidinyl peptide nucleic acid (acpcPNA) probes. A C-terminal lysine-modified acpcPNA was immobilized through four different alkanethiol self-assembled monolayers (SAMs), i.e., 3-mercaptopropionic acid (MPA), thioctic acid (TA), thiourea (TU) and mercaptosuccinic acid (MSA). The hybridization between the acpcPNA probes and the target DNA was directly measured using the capacitive system. Five blocking thiols of various lengths (C=3, 6, 8, 9 and 11), with the -OH terminating head group, i.e., 3-mercapto-1-propanol (3-MPL), 6-mercapto-1-hexanol (6-MHL), 8-mercapto-1-octanol (8-MOL), 9-mercapto-1-nonanol (9-MNL), 11-mercapto-1-undecanol (11-MUL) and another blocking thiol (C=11) with a -CH(3) terminating head group, and 1-dodecanethiol (1-DDT) were investigated. The blocking thiol with the same length as the total spacer of the immobilized acpcPNA gave the highest sensitivity and specificity with the -OH terminating head group providing a slightly better signal than the -CH(3) group. Under the optimized conditions, the immobilized acpcPNA probes provided a wide linear range for DNA detection (1.0×10(-11)-1.0×10(-8)M) with a very low detection limit in the picomolar range. The modified acpcPNA electrode could be reused through at least 58 cycles. The high sensitivity and very low detection limits are potentially useful for the analysis of ultra-trace levels of DNA in samples. Preliminary studies were also performed to see the effect of probe concentration and target length.  相似文献   
6.
Radical copolymerization of acrylamide (Am) (90 mol%) with N-acryloyl-m-aminophenylboronic acid (NAAPBA) (10 mol%) carried out on the surface of glass slides in aqueous solution and in the absence of chemical cross-linkers, resulted in the formation of thin semitransparent gels. The phenylboronic acid (PBA) ligand density was ca. 160 micromol/ml gel. The gels exhibited a macroporous structure and displayed optical response to sucrose, lactose, glucose and fructose in 50 mM sodium phosphate buffer, in the pH range from 6.5 to 7.5. The response was fairly reversible and linearly depended on glucose concentration in the wide concentration range from 1 to 60 mM at pH 7.3. The character of response was explained by the balance of two competing equilibrium processes: binding of glucose to phenylboronate anions and binary hydrophobic interactions of neutral PBA groups. The apparent diffusion coefficient of glucose in the gels was ca. 2.5 x 10(-7) cm(2)/s. A freshly prepared gel can be used daily for at least 1 month without changes in sensitivity. Autoclaving (121 degrees C, 1.2 bar, 10 min) allows for the gels sterilization, which is important for their use as glucose sensors in fermentation processes.  相似文献   
7.
A procedure was developed for the covalent coupling of anti-alpha-fetoprotein antibody (anti-AFP) to a gold surface modified with a self-assembled monolayer (SAM) of thiourea (TU). The performance of the SAM-antibody layer was compared to those of similar layers based on thioctic acid (TA) and 3-mercaptopropionic acid (MPA) by using flow injection capacitive immunosensor system. Covalent coupling of anti-AFP on self-assembled thiourea monolayer (SATUM) modified gold electrode can be used to detect alpha-fetoprotein with high efficiency, similar sensitivity, the same linear range (0.01-10 microgl(-1)) and detection limit (10 ngl(-1)) as those obtained from sensors based on self-assembled thioctic acid monolayer (SATAM) and self-assembled 3-mercaptopropionic acid monolayer (SAMPAM). The system is specific for alpha-fetoprotein and can be regenerated and reused up to 48 times. Therefore, self-assembled monolayer using thiourea which is cheaper than thioctic acid and 3-mercaptopropionic acid is a good alternative for biosensor applications when SAMs are used.  相似文献   
8.

Authors Index

Author index Volume 49 2000  相似文献   
9.
A multilayer electrode modified with a self-assembled thiourea monolayer (SATUM) followed by gold nanoparticles (AuNPs), mercaptosuccinic acid (MSA) and antibody was investigated for the detection of ultra trace amount of a small molecule (chloramphenicol) in an impedimetric system. The formation of the antibody-antigen complex at the electrode surface caused the impedance to increase. Under optimum conditions three modified electrodes were compared the SATUM/AuNPs/MSA electrode provided a wide linear range (0.50-10) × 10?1? M, and a very low determination limit of 1.0 × 10?1? M. This determination limit was much lower than the SATUM/AuNPs electrode, 1.0 × 10?1? M, and SATUM electrode, 4.7 × 10?1? M. The modified electrode provided good selectivity for chloramphenicol detection and can be reused up to 45 times with a relative standard deviation of lower than 4%. When applied to determine chloramphenicol in shrimp samples, the results agreed well with those obtained by the high-performance liquid chromatography coupled with a photo diode array detector (P > 0.05). The developed system can be applied to detect other small molecules using appropriate affinity binding pairs.  相似文献   
10.
A label-free immunosensor based on a modified gold electrode incorporated with silver (Ag) nanoparticles (NPs) to enhance the capacitive response to microcystin-LR (MCLR) has been developed. Anti-microcystin-LR (anti-MCLR) was immobilized on silver nanoparticles bound to a self-assembled thiourea monolayer. Interaction of anti-MCLR and MCLR were directly detected by capacitance measurement. Under optimum conditions, MCLR could be determined with a detection limit of 7.0pgl(-1) and linearity between 10pgl(-1) and 1mugl(-1). The immobilized anti-MCLR on self-assembled thiourea monolayer incorporated with silver nanoparticles was stable and good reproducibility of the signal could be obtained up to 43 times with an R.S.D. of 2.1%. Comparing to the modified electrode without silver nanoparticles it gave 1.7-fold higher sensitivity and lower limit of detection. The developed immunosensor was applied to analyze MCLR in water samples and the results were in good agreement with those obtained by high-performance liquid chromatography (HPLC) (P<0.05).  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号