首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   10篇
  免费   0篇
  2016年   1篇
  2014年   1篇
  2012年   3篇
  2011年   1篇
  2009年   1篇
  2007年   1篇
  2003年   1篇
  1971年   1篇
排序方式: 共有10条查询结果,搜索用时 15 毫秒
1
1.
While others have reported short-term comparisons between various minimally invasive surgical (MIS) approaches to total hip arthroplasty (THA) and their conventional analogues, longer-term data is lacking, as is information indicating whether MIS approaches to THA provide a biomechanically complete recovery. Furthermore, different MIS approaches have not been compared. Our approaches of interest were a one-incision modified Watson-Jones, and a two-incision approach. Hypotheses: (1) There are significant differences in gait recovery patterns between the two surgical groups and (2) THA subjects have significant differences in function one year after surgery compared to control subjects. To test these hypotheses, THA candidates (n=26) were randomized to receive one of these MIS approaches and evaluated preoperatively, and postoperatively at 3 weeks, and at 3, 6 and 12 months. Evaluations included three-dimensional gait analysis and 24-hour step-counts. The same data were obtained from 25 control subjects. Recovery time-course was assessed using repeated measures ANOVA. T-tests were used to compare controls with the pooled group of THA subjects. We found no differences between the two THA surgical groups regarding the time-course of recovery (p≥0.591). Although recovery was statistically complete by 3 months postoperatively for all variables, there were significant differences from controls at 12 months. Most notably, the external hip adduction moment, which reflects hip abductor function, was more than one standard deviation below normal (p<0.001). THA subject inactivity could not explain the gait differences, since one year after surgery daily step counts were not significantly different from controls (p=0.346). More work is necessary to determine ways to improve biomechanical outcomes for today's patients with high expectations for function and implant longevity.  相似文献   
2.
3.

Introduction

High joint loading, knee muscle weakness, and poor proprioceptive acuity are important factors that have been linked to knee osteoarthritis (OA). We previously reported that those with unilateral hip OA and bilateral asymptomatic knees are more predisposed to develop progressive OA in the contralateral knee relative to the ipsilateral knee. In the present study, we evaluate asymmetries in muscle strength and proprioception between the limbs and also evaluate relationships between these factors and joint loading that may be associated with the asymmetric evolution of OA in this group.

Methods

Sixty-two participants with symptomatic unilateral hip OA and asymptomatic knees were evaluated for muscle strength, joint position sense and dynamic joint loads at the knees. Muscle strength and proprioception were compared between limbs and correlations between these factors and dynamic joint loading were evaluated. Subgroup analyses were also performed in only those participants that fulfilled criteria for severe hip OA.

Results

Quadriceps muscle strength was 15% greater, and in the severe subgroup, proprioceptive acuity was 25% worse at the contralateral compared to ipsilateral knee of participants with unilateral hip OA (P <0.05). In addition, at the affected limb, there was an association between decreased proprioceptive acuity and higher knee loading (Spearman’s rho = 0.377, P = 0.007) and between decreased proprioceptive acuity and decreased muscle strength (Spearman’s rho = −0.328, P = 0.016).

Conclusions

This study demonstrated asymmetries in muscle strength and proprioception between the limbs in a unilateral hip OA population. Early alterations in these factors suggest their possible role in the future development of OA at the contralateral ‘OA-predisposed knee’ in this group. Furthermore, the significant association observed between proprioception, loading, and muscle strength at the affected hip limb suggests that these factors may be interrelated.  相似文献   
4.
In vivo knee contact forces are difficult to determine using numerical methods because there are more unknown forces than equilibrium equations available. We developed parametric methods for computing contact forces across the knee joint during the stance phase of level walking. Three-dimensional contact forces were calculated at two points of contact between the tibia and the femur, one on the lateral aspect of the tibial plateau, and one on the medial side. Muscle activations were parametrically varied over their physiologic range resulting in a solution space of contact forces. The obtained solution space was reasonably small and the resulting force pattern compared well to a previous model from the literature for kinematics and external kinetics from the same patient. Peak forces of the parametric model and the previous model were similar for the first half of the stance phase, but differed for the second half. The previous model did not take into account the transverse external moment about the knee and could not calculate muscle activation levels. Ultimately, the parametric model will result in more accurate contact force inputs for total knee simulators, as current inputs are not generally based on kinematics and kinetics inputs from TKR patients.  相似文献   
5.
An analytical parametric model was developed to estimate the natural biological variations in muscle forces and their effect on the hip forces subject only to physiological constraints and not predefined optimization criterion. Force predictions are based on the joint kinematics and kinetics of each subject, a previously published muscle model, and physiological constraints on the muscle force distributions. The model was used to determine the hip contact forces throughout the stance phase of gait of a subject with a total hip replacement (THR). The parametrically modeled peak hip force without antagonistic muscle activity varied from 2.7 to 3.2 Body Weights (mean 2.9 Body Weights), which agreed well with published in vivo measurements from instrumented THRs in other subjects. For every 10% increase in antagonistic activity, the mean peak hip force increased by 0.2 Body Weights. The parametric model allows one to examine the effect of specific muscle weaknesses or increased antagonistic muscle activity on the hip forces. The model also provides a tool for studying the effect of gait adaptations on hip forces, as predictions are based on each individual's gait data. Differences in peak forces between subjects can then be evaluated relative to the uncertainty in not knowing the precise muscle force distributions.  相似文献   
6.
Knee joint forces measured from instrumented implants provide important information for testing the validity of computational models that predict knee joint forces. The purpose of this study was to validate a parametric numerical model for predicting knee joint contact forces against measurements from four subjects with instrumented TKRs during the stance phase of gait. Model sensitivity to abnormal gait patterns was also investigated. The results demonstrated good agreement for three subjects with relatively normal gait patterns, where the difference between the mean measured and calculated forces ranged from 0.05 to 0.45 body weights, and the envelopes of measured and calculated forces (from three walking trials) overlapped. The fourth subject, who had a "quadriceps avoidance" external moment pattern, initially had little overlap between the measured and calculated force envelopes. When additional constraints were added, tailored to the subject's gait pattern, the model predictions improved to complete force envelope overlap. Coefficient of multiple determination analysis indicated that the shape of the measured and calculated force waveforms were similar for all subjects (adjusted coefficient of multiple correlation values between 0.88 and 0.92). The parametric model was accurate in predicting both the magnitude and waveform of the contact force, and the accuracy of model predictions was affected by deviations from normal gait patterns. Equally important, the envelope of forces generated by the range of solutions substantially overlapped with the corresponding measured envelope from multiple gait trials for a given subject, suggesting that the variable strategic processes of in vivo force generation are covered by the solution range of this parametric model.  相似文献   
7.
A midstance reversal of sagittal plane hip motion during walking, or motion discontinuity (MD), has previously been observed in subjects with endstage hip osteoarthritis (OA) and in patients with femoroacetabular impingement. The goal of the present study was to evaluate whether this gait pattern is a marker of OA presence or radiographic severity by analyzing a large IRB approved motion analysis data repository. We also hypothesized that subjects with the MD would show more substantial gait impairments than those with normal hip motion. We identified 150 subjects with symptomatic unilateral hip OA and Kellgren-Lawrence OA severity data on file, and a control group of 159 asymptomatic subjects whose ages fell within 2 standard deviations of the mean OA group age. From the gait data, the MD was defined as a reversal in the slope of the hip flexion angle curve during midstance. Logistic regressions and general linear models were used to test the association between the MD and OA presence, OA severity and, other gait variables. 53% of OA subjects compared to 7.5% of controls had the MD (p<0.001); occurrence of the MD was associated with OA severity (p=0.009). Within the OA subject group, subjects with the MD had reduced dynamic range of motion, peak, extension, and internal rotation moments compared to those who did not (MANCOVA p ≤ 0.042) after controlling for walking speed. We concluded that sagittal plane motion reversals are indeed associated with OA presence and severity, and with more severe gait abnormalities in subjects with hip OA.  相似文献   
8.
9.
The purpose of this study was to evaluate whether preoperative gait adaptations persist one year after THR in the same set of subjects. The hypothesis tested was that hip dynamic range of motion and peak external moments during walking return to normal after THR. Hip kinematics and kinetics were measured for 28 subjects before and one year after THR and compared to those of 25 subjects with radiographically normal hips. All THR subjects improved clinically after surgery with Harris hip scores improving from 33-85 (average 53) to 61-100 (average 95) (sign test p<0.001). Preoperatively dynamic hip range of motion (ROM), and all peak external moments were reduced compared to normal (Mann-Whitney p< or =0.040). Improvement was seen in the ROM and all but the frontal plane, and external rotation peak moments (Friedman p< or =0.023). The preoperative and postoperative values of the ROM, and peak flexion, abduction and external rotation moments were all significantly correlated (Spearman p<0.020) indicating a possible learned effect from before THR surgery. Postoperative THR subjects continued to have a significantly lower than normal ROM, and peak adduction and peak internal rotation moments (Mann-Whitney p< or =0.003). Despite good to excellent clinical functional outcome, gait in THR patients does not return to normal by one year after surgery. Aggressive muscle strengthening is currently not emphasized after THR surgery. Some THR patients may benefit from more intensive rehabilitation before and after surgery.  相似文献   
10.
Hoteit I  Kharma N  Varin L 《Bio Systems》2012,109(1):57-71
We present a detailed and extendable design of the first synchronous single-input delay flip-flop implemented as a gene regulatory network in Escherichia coli (E. coli). The device, which we call the BioD, has one data input (transacting RNA), one clock input (far-red light) and an output that reports the state of the device using green fluorescent protein (GFP). The proposed design builds on Gardner's toggle switch, to provide a more sophisticated device that can be synchronized with other devices within the same cell, and which requires only one data input. We provide a mathematical model of the system and simulation results. The results show that the device behaves in line with desired functionality. Further, we discuss the constraints of the design, which pertain to ranges of parameter values. The BioD is extended via the addition of an update function and input and output interfaces. The result is the BioFSM, which constitutes a synchronous and modular finite state machine, which uses an update function to change its state, stored in the BioD. The BioFSM uses its input and output interfaces for inter-cellular communications. This opens the door to the design of a circular cellular automata (the BioCell), which is envisioned as a number of communicating E. coli colonies, each made of clones of one BioFSM.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号