全文获取类型
收费全文 | 82篇 |
免费 | 10篇 |
出版年
2023年 | 1篇 |
2021年 | 1篇 |
2020年 | 2篇 |
2019年 | 1篇 |
2018年 | 5篇 |
2017年 | 4篇 |
2016年 | 3篇 |
2015年 | 4篇 |
2014年 | 1篇 |
2013年 | 5篇 |
2012年 | 5篇 |
2011年 | 9篇 |
2010年 | 4篇 |
2009年 | 4篇 |
2008年 | 6篇 |
2007年 | 4篇 |
2006年 | 4篇 |
2005年 | 6篇 |
2004年 | 3篇 |
2003年 | 3篇 |
2002年 | 2篇 |
2001年 | 2篇 |
2000年 | 2篇 |
1999年 | 2篇 |
1997年 | 1篇 |
1991年 | 2篇 |
1990年 | 1篇 |
1989年 | 2篇 |
1988年 | 1篇 |
1987年 | 1篇 |
1986年 | 1篇 |
排序方式: 共有92条查询结果,搜索用时 46 毫秒
1.
Strength conditioning in older men: skeletal muscle hypertrophy and improved function 总被引:9,自引:0,他引:9
Frontera W. R.; Meredith C. N.; O'Reilly K. P.; Knuttgen H. G.; Evans W. J. 《Journal of applied physiology》1988,64(3):1038-1044
The effects of strength conditioning on skeletal muscle function and mass were determined in older men. Twelve healthy untrained volunteers (age range 60-72 yr) participated in a 12-wk strength training program (8 repetitions/set; 3 sets/day; 3 days/wk) at 80% of the one repetition maximum (1 RM) for extensors and flexors of both knee joints. They were evaluated before the program and after 6 and 12 wk of training. Weekly measurements of 1 RM showed a progressive increase in strength in extensors and flexors. By 12 wk extensor and flexor strength had increased 107.4 (P less than 0.0001) and 226.7% (P less than 0.0001), respectively. Isokinetic peak torque of extensors and flexors measured on a Cybex II dynamometer increased 10.0 and 18.5% (P less than 0.05) at 60 degrees/s and 16.7 and 14.7% (P less than 0.05) at 240 degrees/s. The torque-velocity relationship showed an upward displacement of the curve at the end of training, mainly in the slow-velocity high-torque region. Midthigh composition from computerized tomographic scans showed an increase (P less than 0.01) in total thigh area (4.8%), total muscle area (11.4%), and quadriceps area (9.3%). Biopsies of the vastus lateralis muscle revealed similar increases (P less than 0.001) in type I fiber area (33.5%) and type II fiber area (27.6%). Daily excretion of urinary 3-methyl-L-histidine increased with training (P less than 0.05) by an average 40.8%. Strength gains in older men were associated with significant muscle hypertrophy and an increase in myofibrillar protein turnover. 相似文献
2.
Evans W. J.; Meredith C. N.; Cannon J. G.; Dinarello C. A.; Frontera W. R.; Hughes V. A.; Jones B. H.; Knuttgen H. G. 《Journal of applied physiology》1986,61(5):1864-1868
The effects of one 45-min bout of high-intensity eccentric exercise (250 W) were studied in four male runners and five untrained men. Plasma creatine kinase (CK) activity in these runners was higher (P less than 0.001) than in the untrained men before exercise and peaked at 207 IU/ml 1 day after exercise, whereas in untrained men the maximum was 2,143 IU/ml 5 days after exercise. Plasma interleukin-1 (IL-1) in the trained men was also higher (P less than 0.001) than in the untrained men before exercise but did not significantly increase after exercise. In the untrained men, IL-1 was significantly elevated 3 h after exercise (P less than 0.001). In the untrained group only, 24-h urines were collected before and after exercise while the men consumed a meat-free diet. Urinary 3-methylhistidine/creatinine in the untrained group rose significantly from 127 mumol/g before exercise to 180 mumol/g 10 days after exercise. The results suggest that in untrained men eccentric exercise leads to a metabolic response indicative of delayed muscle damage. Regularly performed long distance running was associated with chronically elevated plasma IL-1 levels and serum CK activities without acute increases after an eccentric exercise bout. 相似文献
3.
4.
5.
Effect of crown ethers on structure, stability, activity, and enantioselectivity of subtilisin Carlsberg in organic solvents. 总被引:2,自引:0,他引:2
A M Santos M Vidal Y Pacheco J Frontera C Báez O Ornellas G Barletta K Griebenow 《Biotechnology and bioengineering》2001,74(4):295-308
Colyophilization or codrying of subtilisin Carlsberg with the crown ethers 18-crown-6, 15-crown-5, and 12-crown-4 substantially improved enzyme activity in THF, acetonitrile, and 1,4-dioxane in the transesterification reactions of N-acetyl-L-phenylalanine ethylester and 1-propanol and that of (+/-)-1-phenylethanol and vinylbutyrate. The acceleration of the initial rate, V(0), ranged from less than 10-fold to more than 100-fold. All crown ethers activated subtilisin substantially, which excludes a specific macrocyclic effect from being responsible. The secondary structure of subtilisin was studied by Fourier-transform infrared (FTIR) spectroscopy. 18-Crown-6 and 15-crown-5 led to a more nativelike structure of subtilisin in the organic solvents employed when compared with that of the dehydrated enzyme obtained from buffer alone. However, the high level of activation with 12-crown-4 where this effect was not observed excluded overall structural preservation from being the primary cause of the observed enzyme activation. The conformational mobility of subtilisin was investigated by performing thermal denaturation experiments in 1,4-dioxane. Although only a small effect of temperature on subtilisin structure was observed for the samples prepared with or without 12-crown-4, both 18-crown-6 and 15-crown-5 caused the enzyme to denature at quite low temperatures (38 degrees C and 56 degrees C, respectively). No relationship between this property and V(0) was evident, but increased conformational mobility of the protein decreased its storage stability. The possibility of a "molecular imprinting" effect was also tested by removing 18-crown-6 from the subtilisin-18-crown-6 colyophilizate by washing. V(0) was only halved as a result of this procedure, an effect insignificant compared with the ca. 80-fold rate enhancement observed prior to washing in THF. This suggests that molecular imprinting is likely the primary cause of subtilisin activation by crown ethers, as recently suggested. 相似文献
6.
Drink composition, voluntary drinking, and fluid balance in exercising, trained, heat-acclimatized boys 总被引:2,自引:0,他引:2
Rivera-Brown Anita M.; Gutierrez Randall; Gutierrez Juan Carlos; Frontera Walter R.; Bar-Or Oded 《Journal of applied physiology》1999,86(1):78-84
This study examinedthe effects of beverage composition on the voluntary drinking pattern,body fluid balance, and thermoregulation of heat-acclimatized trainedboys exercising intermittently in outdoor conditions (wet bulb globetemperature 30.4 ± 1.0°C). Twelve boys (age 13.4 ± 0.4 yr) performed two 3-h sessions, each consisting of four20-min cycling bouts at 60% maximal aerobic power alternating with25-min rest. One of two beverages was assigned: unflavored water (W) orflavored water plus 6% carbohydrate and 18 mmol/l Na (CNa). Drinkingwas ad libitum. Total intake was higher(P < 0.05) during CNa (1,943 ± 190 g) compared with W (1,470 ± 143 g). Euhydration wasmaintained with CNa (+0.18% body wt), but a mild dehydration resultedwith W (0.94% body wt; P < 0.05). Sweat loss, much higher than previously published for children of similar age, was similar between conditions (CNa = 1,644.7 ± 117.5; W = 1,750.2 ± 152.7 g). The increase in rectaltemperature (CNa = 0.86 ± 0.3; W = 0.76 ± 0.1°C), heartrate, and all perceptual variables did not differ between conditions.In conclusion, a flavored carbohydrate-electrolyte drink preventsvoluntary dehydration in trained heat-acclimatized boys exercising in atropical climate despite their large sweat losses. Because hydrationchanges were minor, the thermoregulatory strain observed was similarbetween conditions. 相似文献
7.
8.
9.
D.G. Wilson N. Ahmed R. Nolan A. Frontera G. Thomas E.R. Duncan 《Indian pacing and electrophysiology journal》2015,15(1):4-14
AimsLimited data exist on outcomes in very elderly ICD recipients. We describe outcomes in new ICD and Cardiac Resynchronisation Therapy with Defibrillator (CRT-D) implants in octogenarians at our institution.MethodsPatients aged 80 years and above who underwent de novo ICD or CRT-D implantation from January 2006 to July 2012 were identified. Clinical data were collected from the procedural record, medical and ICD notes. Baseline characteristics were compared using independent sample t test for continuous variables and Fisher’s exact test for categorical variables. Kaplan-Meier curves were constructed.ResultsTen per cent of all new ICD/CRT-D implants were aged 80 years and over. Median age was 83.0 years. Median follow-up was 29 months. Death occurred in 17 (34%). Median time to death was 23 months. Three deaths (6%) occurred within 12 months of ICD implantation. Appropriate therapy (ATP or shock) occurred in 19 (38%). Inappropriate therapy occurred in 6 (12%).Rates of appropriate shocks and inappropriate therapy (shocks and ATP) and significant valvular incompetence were higher amongst deceased patients (P=0.03 OR 5.9 95% CI 1.3-27) and (P=0.02 OR 12 95% CI 1.3-112). Univariate analysis identified diuretic use (P=0.008 95% C.I. 0.05 to 0.63) and appropriate shock (P= 0.025 95% C.I. 1.25 to 26.3) as predictors of mortality.ConclusionOctogenarians make up a small but increasing number of ICD recipients. This study highlights high survival rates at one year with acceptable rates of appropriate and inappropriate device therapy. Ongoing debate regarding the appropriateness of ICD in very elderly patients is warranted.Key words: sudden cardiac death, implantable defibrillators, octogenarians 相似文献
10.