首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   15篇
  免费   1篇
  2017年   1篇
  2015年   2篇
  2014年   1篇
  2013年   2篇
  2012年   2篇
  2011年   1篇
  2010年   1篇
  2008年   1篇
  2007年   3篇
  2006年   1篇
  1974年   1篇
排序方式: 共有16条查询结果,搜索用时 15 毫秒
1.
Early detection and accurate estimation of aortic stenosis (AS) severity are the most important predictors of successful long-term outcomes in patients. Current clinical parameters used for evaluation of the AS severity have several limitations including flow dependency. Estimation of AS severity is specifically challenging in patients with low-flow and low transvalvular pressure gradient conditions. A proper diagnosis in these patients needs a comprehensive evaluation of the left ventricle (LV) hemodynamic loads. This study has two objectives: (1) developing a lumped-parameter model to describe the ventricular-valvular-arterial interaction and to estimate the LV stroke work (SW); (2) introducing and validating a new index, the normalized stroke work (N-SW), to assess the global hemodynamic load imposed on the LV. N-SW represents the global hemodynamic load that the LV faces for each unit volume of blood ejected. The model uses a limited number of parameters which all can be measured non-invasively using current clinical imaging modalities. The model was first validated by comparing its calculated flow waveforms with the ones measured using Cardiovascular Magnetic Resonance (CMR) in 49 patients and 8 controls. A very good correlation and concordance were found throughout the cycle (median root mean square: 12.21 mL/s) and between the peak values (r = 0.98; SEE = 0.001, p<0.001). The model was then used to determine SW using the parameters measured with transthoracic Doppler-echocardiography (TTE) and CMR. N-SW showed very good correlations with a previously-validated index of global hemodynamic load, the valvular arterial impedance (), using data from both imaging modalities (TTE: r = 0.82, SEE = 0.01, p<0.001; CMR: r = 0.74, SEE = 0.01, p<0.001). Furthermore, unlike , N-SW was almost independent from variations in the flow rate. This study suggests that considering N-SW may provide incremental diagnostic and prognostic information, beyond what standard indices of stenosis severity and provide, particularly in patients with low LV outflow.  相似文献   
2.
Fur is a bacterial regulator using iron as a cofactor to bind to specific DNA sequences. This protein exists in solution as several oligomeric states, of which the dimer is generally assumed to be the biologically relevant one. We describe the equilibria that exist between dimeric Escherichia coli Fur and higher oligomers. The dissociation constant for the dimer-tetramer equilibrium is estimated to be in the millimolar range. Oligomerization is enhanced at low ionic strength and pH. The as-isolated monomeric form of Fur is not in equilibrium with the dimer and contains two disulfide bridges (C92-C95 and C132-C137). Binding of the monomer to DNA is metal-dependent and sequence specific with an apparent affinity 5.5 times lower than that of the dimer. Size exclusion chromatography, EDC cross-linking, and CD spectroscopy show that reconstitution of the dimer from the monomer requires reduction of the disulfide bridges and coordination of Zn2+. Reduction of the disulfide bridges or Zn2+ alone does not promote dimerization. EDC and DMA cross-links reveal that the N-terminal NH2 group of one subunit is in an ionic interaction with acidic residues of the C-terminal tail and close to Lys76 and Lys97 of the other. Furthermore, the yields of cross-link drastically decrease upon binding of metal in the activation site, suggesting that the N-terminus is involved in the conformational change. Conversely, oxidizing reagents, H2O2 or diamide, disrupt the dimeric structure leading to monomer formation. These results establish that coordination of the zinc ion and the redox state of the cysteines are essential for holding E. coli Fur in a dimeric state.  相似文献   
3.
4.
Europium trivalent (Eu3+)‐doped Y2O3 nanopowders of different concentrations (0.5, 2.5, 5 or 7 at.%) were synthesized by the sol‐gel method, at different pH values (pH 2, 5 or 8) and annealing temperatures (600°C, 800°C or 1000°C). The nanopowders samples were characterized by X‐ray diffraction (XRD), field emission scanning electron microscopy (FE‐SEM), Fourier transform infrared spectroscopy (FT‐IR) and steady state photoluminescence spectroscopy. The effect of pH of solution and annealing temperatures on structural, morphological and photoluminescence properties of Eu3+‐doped Y2O3 were studied and are discussed. It was found that the average crystallite size of the nanopowders increased with increasing pH and annealing temperature values. The Y2O3:Eu3+ material presented different morphology and its evolution depended on the pH value and the annealing temperature. Activation energies at different pH values were determined and are discussed. Under ultraviolet (UV) light excitation, Y2O3:Eu3+ showed narrow emission peaks corresponding to the 5D0–7FJ (J = 0, 1, 2 and 3) transitions of the Eu3+ ion, with the most intense red emission at 611 assigned to forced electric dipole 5D07F2. The emission intensity became more intense with increasing annealing temperature and pH values, related to the improvement of crystalline quality. For the 1000°C annealing temperature, the emission intensity presented a maximum at pH 5 related to the uniform cubic‐shaped particles. It was found that for lower annealing temperatures (small crystallite size) the CTB (charge transfer band) position presented a red shift. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   
5.
Early detection and accurate estimation of COA severity are the most important predictors of successful long-term outcome. However, current clinical parameters used for the evaluation of the severity of COA have several limitations and are flow dependent. The objectives of this study are to evaluate the limitations of current existing parameters for the evaluation of the severity of coarctation of the aorta (COA) and suggest two new parameters: COA Doppler velocity index and COA effective orifice area. Three different severities of COAs were tested in a mock flow circulation model under various flow conditions and in the presence of normal and stenotic aortic valves. Catheter trans-COA pressure gradients and Doppler echocardiographic trans-COA pressure gradients were evaluated. COA Doppler velocity index was defined as the ratio of pre-COA to post-COA peak velocities measured by Doppler echocardiography. COA Doppler effective orifice area was determined using continuity equation. The results show that peak-to-peak trans-COA pressure gradient significantly increased with flow rate (from 83% to 85%). Peak Doppler pressure gradient also significantly increased with flow rate (80-85%). A stenotic or bicuspid aortic valve increased peak Doppler pressure gradient by 20-50% for a COA severity of 75%. Both COA Doppler velocity index and COA effective orifice area did not demonstrate significant flow dependence or dependence upon aortic valve condition. As a conclusion, COA Doppler velocity index and COA effective orifice area are flow independent and do not depend on aortic valve conditions. They can, then, more accurately predict the severity of COA.  相似文献   
6.
Aortic valve bypass (AVB) has been shown to be a viable solution for patients with severe aortic stenosis (AS). Under this circumstance, the left ventricle (LV) has a double outlet. The objective was to develop a mathematical model capable of evaluating the hemodynamic performance following the AVB surgery. A mathematical model that captures the interaction between LV, AS, arterial system, and AVB was developed. This model uses a limited number of parameters that all can be non-invasively measured using patient data. The model was validated using in vivo data from the literature. The model was used to determine the effect of different AVB and AS configurations on flow proportion and pressure of the aortic valve and the AVB. Results showed that the AVB leads to a significant reduction in transvalvular pressure gradient. The percentage of flow through the AVB can range from 55.47% to 69.43% following AVB with a severe AS. LV stroke work was also significantly reduced following the AVB surgery and reached a value of around 1.2 J for several AS severities. Findings of this study suggest: 1) the AVB leads to a significant reduction in transvalvular pressure gradients; 2) flow distribution between the AS and the AVB is significantly affected by the conduit valve size; 3) the AVB leads to a significant reduction in LV stroke work; and 4) hemodynamic performance variations can be estimated using the model.  相似文献   
7.
Up to 80% of patients with coarctation of the aorta (COA) have a bicuspid aortic valve (BAV). Patients with COA and BAV have elevated risks of aortic complications despite successful surgical repair. The development of such complications involves the interplay between the mechanical forces applied on the artery and the biological processes occurring at the cellular level. The focus of this study is on hemodynamic modifications induced in the aorta in the presence of a COA and a BAV. For this purpose, numerical investigations and magnetic resonance imaging measurements were conducted with different configurations: (1) normal: normal aorta and normal aortic valve; (2) isolated COA: aorta with COA (75% reduction by area) and normal aortic valve; (3) complex COA: aorta with the same severity of COA (75% reduction by area) and BAV. The results show that the coexistence of COA and BAV significantly alters blood flow in the aorta with a significant increase in the maximal velocity, secondary flow, pressure loss, time-averaged wall shear stress and oscillatory shear index downstream of the COA. These findings can contribute to a better understanding of why patients with complex COA have adverse outcome even following a successful surgery.  相似文献   
8.
The capture of a specimen of the bluefish– Pomatomus saltatrix , (L. 1758) off Ballycotton, Co. Cork, Ireland (Lat. 8°W, Long. 51°50'N) is reported. Some diagnostic features and measurements of the specimen are given. This would appear to be the first record of the species for the Eastern Atlantic, north of Spain.  相似文献   
9.
In presence of aortic stenosis, a jet is produced downstream of the aortic valve annulus during systole. The vena contracta corresponds to the location where the cross-sectional area of the flow jet is minimal. The maximal transvalvular pressure gradient (TPGmax) is the difference between the static pressure in the left ventricle and that in the vena contracta. TPGmax is highly time-dependent over systole and is known to depend upon the transvalvular flow rate, the effective orifice area (EOA) of the aortic valve and the cross-sectional area of the left ventricular outflow tract. However, it is still unclear how these parameters modify the TPGmax waveform. We thus derived an explicit analytical model to describe the instantaneous TPGmax across the aortic valve during systole. This theoretical model was validated with in vivo experiments obtained in 19 pigs with supravalvular aortic stenosis. Instantaneous TPGmax was measured by catheter and its waveform was compared with the one determined from the derived equation. Our results showed a very good concordance between the measured and predicted instantaneous TPGmax. Total relative error and mean absolute error were on average 9.4±4.9% and 2.1±1.1 mmHg, respectively. The analytical model proposed and validated in this study provides new insight into the behaviour of the TPGmax and thus of the aortic pressure at the level of vena contracta. Because the static pressure at the coronary inlet is similar to that at the vena contracta, the proposed equation will permit to further examine the impact of aortic stenosis on coronary blood flow.  相似文献   
10.
Although the oxidative destruction of glucose and fructose has been studied by several investigators over the past century, the mechanism by which phosphate promotes these oxidation reactions is not known. A wide range of oxidation products have been used to monitor the oxidation of sugars and free radicals have been shown to be involved. The influence of phosphate concentration on the rate of production of free radicals and several sugar oxidation products has been studied. It was found that fructose is much more susceptible to autoxidation than glucose, galactose, or sucrose. The promotion of sugar oxidation by phosphate was found to be iron dependent. Addition of the iron chelators, diethylenetriaminepentaacetic acid (DTPA) and desferrioxamine completely suppressed the oxidation reactions, even at high concentrations of phosphate. Formaldehyde was positively identified as a product of fructose oxidation by HPLC analysis of its acetylacetone adduct. A mechanism is proposed in which phosphate cleaves the oxo bridges of the iron(III)-fructose complex, based on UV spectral analysis and magnetic susceptibility measurements, and thereby catalyzes the autoxidation of fructose.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号