排序方式: 共有39条查询结果,搜索用时 15 毫秒
1.
在麻醉的32只猫记录了电刺激颌下腺神经支引起的上涎核平均场电位和单位放电。逆行电刺激颌下腺神经支引起的上涎核平均场电位分布在同侧脑干背面闩部头端5.5—8mm处,与过去的组织学结果大致符合。用微电极在上涎核记录了68个对刺激颌下腺神经支有反应的单位,其中33个单位作了碰撞试验。有9个单位符合逆向反应标准,它们是真正的颌下腺节前神经元,逆行反应的潜伏期为14.4±2.5ms,其轴突传导速度为2.9±0.1m/s。其他不符合逆向反应标准的单位,对刺激颌下腺神经支仍能发生反应,估计多为中间神经元。在一部分单位观察了电刺激舌神经或味觉刺激舌引起的反应。根据这些观察对上涎核内存在复杂神经元回路的可能性作了讨论。 相似文献
2.
3.
4.
5.
Background
The incidence and prevalence of diabetes are increasing all over the world. Complications of diabetes constitute a burden for the individuals and the whole society. 相似文献6.
Background
When a drug is applied on the skin surface, the concentration of the drug accumulated in the skin and the amount of the drug eliminated into the blood vessel depend on the value of a parameter, r. The values of r depend on the amount of diffusion and the normalized skin-capillary clearence. It is defined as the ratio of the steady-state drug concentration at the skin-capillary boundary to that at the skin-surface in one-dimensional models. The present paper studies the effect of the parameter values, when the region of contact of the skin with the drug, is a line segment on the skin surface. 相似文献7.
Antroduodenal motility in chronic pancreatitis: are abnormalities related to exocrine insufficiency?
Vu MK Vecht J Eddes EH Biemond I Lamers CB Masclee AA 《American journal of physiology. Gastrointestinal and liver physiology》2000,278(3):G458-G466
In patients with chronic pancreatitis (CP) the relation among exocrine pancreatic secretion, gastrointestinal hormone release, and motility is disturbed. We studied digestive and interdigestive antroduodenal motility and postprandial gut hormone release in 26 patients with CP. Fifteen of these patients had pancreatic insufficiency (PI) established by urinary para-aminobenzoic acid test and fecal fat excretion. Antroduodenal motility was recorded after ingestion of a mixed liquid meal. The effect of pancreatic enzyme supplementation was studied in 8 of the 15 CP patients with PI. The duration of the postprandial antroduodenal motor pattern was significantly (P < 0.01) prolonged in CP patients (324 +/- 20 min) compared with controls (215 +/- 19 min). Antral motility indexes in the first hour after meal ingestion were significantly reduced in CP patients. The interdigestive migrating motor complex cycle length was significantly (P < 0.01) shorter in CP patients (90 +/- 8 min) compared with controls (129 +/- 8 min). These abnormalities were more pronounced in CP patients with exocrine PI. After supplementation of pancreatic enzymes, these alterations in motility reverted toward normal. Digestive and interdigestive antroduodenal motility are abnormal in patients with CP but significantly different from controls only in those with exocrine PI. These abnormalities in antroduodenal motility in CP are related to maldigestion. 相似文献
8.
Gustafsson JO Eddes JS Meding S Koudelka T Oehler MK McColl SR Hoffmann P 《Journal of Proteomics》2012,75(16):5093-5105
One of the important challenges for MALDI imaging mass spectrometry (MALDI-IMS) is the unambiguous identification of measured analytes. One way to do this is to match tryptic peptide MALDI-IMS m/z values with LC-MS/MS identified m/z values. Matching using current MALDI-TOF/TOF MS instruments is difficult due to the variability of in situ time-of-flight (TOF) m/z measurements. This variability is currently addressed using external calibration, which limits achievable mass accuracy for MALDI-IMS and makes it difficult to match these data to downstream LC-MS/MS results. To overcome this challenge, the work presented here details a method for internally calibrating data sets generated from tryptic peptide MALDI-IMS on formalin-fixed paraffin-embedded sections of ovarian cancer. By calibrating all spectra to internal peak features the m/z error for matches made between MALDI-IMS m/z values and LC-MS/MS identified peptide m/z values was significantly reduced. This improvement was confirmed by follow up matching of LC-MS/MS spectra to in situ MS/MS spectra from the same m/z peak features. The sum of the data presented here indicates that internal calibrants should be a standard component of tryptic peptide MALDI-IMS experiments. 相似文献
9.
10.
Klimek J Eddes JS Hohmann L Jackson J Peterson A Letarte S Gafken PR Katz JE Mallick P Lee H Schmidt A Ossola R Eng JK Aebersold R Martin DB 《Journal of proteome research》2008,7(1):96-103
Tandem mass spectrometry (MS/MS) is frequently used in the identification of peptides and proteins. Typical proteomic experiments rely on algorithms such as SEQUEST and MASCOT to compare thousands of tandem mass spectra against the theoretical fragment ion spectra of peptides in a database. The probabilities that these spectrum-to-sequence assignments are correct can be determined by statistical software such as PeptideProphet or through estimations based on reverse or decoy databases. However, many of the software applications that assign probabilities for MS/MS spectra to sequence matches were developed using training data sets from 3D ion-trap mass spectrometers. Given the variety of types of mass spectrometers that have become commercially available over the last 5 years, we sought to generate a data set of reference data covering multiple instrumentation platforms to facilitate both the refinement of existing computational approaches and the development of novel software tools. We analyzed the proteolytic peptides in a mixture of tryptic digests of 18 proteins, named the "ISB standard protein mix", using 8 different mass spectrometers. These include linear and 3D ion traps, two quadrupole time-of-flight platforms (qq-TOF), and two MALDI-TOF-TOF platforms. The resulting data set, which has been named the Standard Protein Mix Database, consists of over 1.1 million spectra in 150+ replicate runs on the mass spectrometers. The data were inspected for quality of separation and searched using SEQUEST. All data, including the native raw instrument and mzXML formats and the PeptideProphet validated peptide assignments, are available at http://regis-web.systemsbiology.net/PublicDatasets/. 相似文献