The present study is aimed at exploring different scanning parameters, detectors and their orientations for time-efficient and accurate commissioning of a 6 MV clinical linear accelerator (LINAC). Beam profiles and percentage depth dose (PDD) curves were measured with a PTW dosimetry diode, a PTW Semiflex and a PinPoint ion chamber in different orientations. To acquire beam data, equidistant (step size of 0.5 mm, 1 mm, 2 mm and 3 mm) and fanline (step size of 2–0.5 mm, 2–1 mm, 3–0.5 mm and 3-1 mm) scanning modes were employed and data measurement time was recorded. Scan time per measurement point was also varied (0.2 s, 0.5 s and 1.0 s) to investigate its effect on the accuracy and acquisition time of beam data. Accuracy of the measured data was analyzed on the basis of the variation between measured data and data modeled by a treatment planning system. Beam profiles (particularly in penumbra region) were found to be sensitive to variation in scanning resolution and showed an improved accuracy with decrease in step size, while PDD curves were affected negligibly. The accuracy of beam data obtained with the PTW dosimetry diode and the PinPoint ion chamber was higher than those obtained with the PTW Semiflex ion chamber for small fields (2?×?2 cm2 and 3?×?3 cm2). However, the response of the PTW diode and the PinPoint ion chamber was significantly indifferent in these fields. Furthermore, axial orientation of the PTW Semiflex ion chamber improved accuracy of profiles and PDDs as compared to radial orientation, while such a difference was not significant for the PinPoint ion chamber. It is concluded that a scan time of 0.2 s/point with a fanline scanning resolution of 2–1 mm for beam profiles and 3 mm for PDDs are most favorable in terms of accuracy and time efficiency. For small fields (2?×?2 cm2 and 3?×?3 cm2), a PinPoint ion chamber in radial orientation or a dosimetry diode in axial orientation are recommended for both beam profiles and PDDs. If a PinPoint ion chamber and a PTW dosimetry diode are not available, a Semiflex ion chamber in axial orientation may be used for small fields.
Suppression subtractive hybridization was carried out to enrich gene fragments over-expressed in rice leaves by subtraction to rice roots, from which two identical cDNA fragments were identified to encode putative phosphoenolpyruvate carboxylase. Then the corresponding full-length cDNA (Osppc) is isolated by RT-PCR and sequenced, which indicates an open reading frame of 2895bp is contained. Its deduced protein is encoded in 10 exons and shows high similarity to many other plant PEPCs. Comparing with maize and bacterial PEPCs, it is revealed that OSPPC shares many conserved domains and active sites that responsible for the structure, activity and regulation of this enzyme. Phylogenetic analysis demonstrates that OSPPC is grouped with C3 form PEPCs of wheat, maize and sorghum, which is consistent with the classification of rice. And a putative promoter element is predicted with DOF binding box, CAAT box and TATA box in the 5'-flanking sequence of Osppc gene. Moreover, Quantitative RT-PCR analyses are performed in hybrid rice and its parents, which show that Osppc is specifically expressed in leaf including leaf vein and sheath. 相似文献
The effect of neurotensin on submaximally-stimulated hepatobiliary and pancreatic secretion was studied in 6 healthy subjects. An intravenous infusion of neurotensin 1.4 ± 0.3 pmol/kg/min, designed to reproduce plasma neurotensin immunoreactivity levels within the physiological range, produced a significant increase in pancreatic bicarbonate output. Plasma concentrations of pancreatic polypeptide rose by 83 ± 16 pmol/l and were associated with a small reduction in trypsin, but no significant change in bilirubin outputs. 相似文献
Abstract A novel synthesis of 3-deazapyrimidine glycosides utilizing pyridine-2(1H)-ones or their sodium salts and α-halomonosugars namely D-glucose or D-galactose as starting components is described. 相似文献
ABSTRACT This study aimed to examine the reliability and the time-of-day effect of the 505 change of direction (CoD), 10-m sprint, and change of direction deficit test (CoDD). At two different time of days, 39 young diurnally active physical education male students performed different physical tests: 505 CoD, and sprint tests. Measurements were taken at two separate testing sessions, i.e. in the morning (07:00–08:30 h) and early evening (17:00–18:30 h) in a randomized and counter-balanced setting on nonconsecutive days in 21 of them (21.5 ± 1.5 y of age). The results showed that the 505 CoD test, 10-m sprint, and CoDD performances were a reliable test, and performances were better in the evening the 505 CoD, 10-m sprint, and CoDD testing provided reliable and sensitive scores. In addition, phase 2 showed that CoD, speed, and CoDD are affected by the time of day. 相似文献
Abstract The synthesis of new 4- and 5-substituted-3-cyanopyridine nucleosides has been performed by reacting the silylated pyridines and penta-O-acetyl-α -D-glycopyranose in dichloroethane in the presence of SnCl4. The free nucleosides were tested for their potential activity against HIV and different types of tumor. 相似文献
AbstractN3-β-D-glucopyranosyl, galactopyranosyl and xylopyranosyl 6-methyl-2-methylthiouracil and their 5-bromo derivatives have been synthesized by coupling an a-acetobromosugar with the corresponding thiouracil. The new modified thiouridine analogues were evaluated for their inhibitory activity against Human Immunodeficiency Virus (HIV) replication in MT-4 cells as well as for their cytotoxicity. 相似文献